Water Quality -
RC-SP-1
-
11/4/2013
Sampled Mine:
York Canyon Underground Mine
Entered By:
Anderson, Monte
Sample Type:
Groundwater
Parameters:
Parameter
Value
Unit
Nondetect?
Alkalinity
1200.000000
mg/L
False
Aluminum
0.100000
mg/L
True
Bicarbonate
1200.000000
mg/L
False
Cadmium
0.005000
mg/L
True
Calcium
29.000000
mg/L
False
Carbonate
5.000000
mg/L
True
Cation/Anion Balance
7.610000
Percent
False
Chloride
15.000000
mg/L
False
FieldpH
7.560000
False
H2OLevel
43.900000
mg/L
False
Hardness
140.000000
mg/L
False
LabEC
2200.000000
umho/cm
False
LabpH
7.480000
False
LabTDS
1400.000000
mg/L
False
Lead
0.009000
mg/L
True
Magnesium
16.000000
mg/L
False
Nitrate
0.055000
mg/L
False
Potassium
7.300000
mg/L
False
SAR
20.000000
mg/L
False
Sodium
510.000000
mg/L
False
Sulfate
70.000000
mg/L
False
Total Fluoride
0.340000
mg/L
False
Total Iron
0.220000
mg/L
False
Total Manganese
0.095000
mg/L
False
Total Mercury
0.000200
mg/L
True
Total Recoverable Selenium
0.015000
mg/L
True
Data entered on
1/16/2014 11:15:46 AM
.