OCD Permitting

30-025-28479 EXXON A FEDERAL #003 [337497]

General Well Information
[333444] 3 Knight's LLC
Active
Oil
New
Vertical
No
Federal
Federal
C-27-24S-32E      660 FNL      1980 FWL
32.1939507,-103.6646957 NAD83
3573


Single
False


Proposed Formation and/or Notes



Depths

4883
4883
4883
0


Formation Tops

Formation Top Producing Method Obtained

Event Dates

12/01/1983
07/25/2025


12/01/1983





12/04/2025

12/01/1985







12/04/2025

History
Effective Date Property Well Number Operator C-101 Work Type Well Type Well Status Apd Cancelled Plug Date
07/25/2025 [337497] EXXON A FEDERAL #003 [333444] 3 Knight's LLC New Oil Active
11/06/2018 [322831] EXXON A FEDERAL #003 [373644] 3 Knights Operating LLC New Oil Active
04/01/2000 [25708] EXXON A FEDERAL #003 [19381] ROBERT H FORREST JR OIL LLC New Oil Active
12/01/1983 [10848] EXXON A FEDERAL #003 [22223] TEMPO ENERGY INC New Oil Active

Comments

Pits & Containments No Pits Found
Id Name Rule Status (Capacity) Type Registration
Inspection
Before *
Earliest Effective
Commencement
Last Effective
Cessation
Inspection
After *
Closure
Report
Reclamation
Report
Restoration
Complete

Casing

  Boreholes, Strings and Equipment Specifications Specifications for Strings and Tubing Strings Cemented and Intervals Cement and Plug Description
String/Hole Type Taper Date Set Diameter Top Bottom (Depth) Grade Length Weight Bot of Cem Top of Cem Meth Class of Cement Sacks Pressure Test (Y/N)
Hole 1 1 9.625 0 990 0 0.0 0 0 0 No
Surface Casing 1 9.625 0 990 990 46.0 990 0 Class C Cement 200 No
Hole 3 1 5.500 0 4883 0 0.0 0 0 0 No
Production Casing 1 5.500 0 4883 4883 17.0 4883 0 Class C Cement 150 No
Packer 1 5.500 4870 4875 5 0.0 0 0 0 No
Tubing 1 1 2.875 0 4870 4870 0.0 0 0 0 No

Well Completions

[19090]  DOUBLE X; DELAWARE

Active
10/01/2025
C-27-24S-32E      660 FNL      1980 FWL

40     27-24S-32E Units: C

No

Flowing

Well Test Data


0 psi
0.000 inches
0.0 MCF
0 Kcf / bbl

0 hours
0 psi

0.0 bbls
0.0 Corr. API
0.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth
4862 4874 0 0

Notes


Event Dates

12/01/1983
07/25/2025



No
No
No
01/01/1984

12/20/1983
04/28/1995









No

01/01/1984





Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
07/25/2025 [337497] EXXON A FEDERAL #003 [333444] 3 Knight's LLC Active
11/06/2018 [322831] EXXON A FEDERAL #003 [373644] 3 Knights Operating LLC Active
04/01/2000 [25708] EXXON A FEDERAL #003 [19381] ROBERT H FORREST JR OIL LLC Active
12/01/1983 [10848] EXXON A FEDERAL #003 [22223] TEMPO ENERGY INC Active

Financial Assurance Please login to review the financial assurance associated with this well.

Compliance

Note that Financial Assurance and Inactive Well Compliance are documented in separate reports (Inactive Well Report, Financial Assurance Report).

Also note that some compliance issues are addressed at the operator level so not listed under each well.



cDA2533857892

Field Inspection
12/04/2025
03/04/2026




Notes

Missing APINumber Missing unit letter Not able to see Well name due to Sticker. Of Operator

Actions/Events

Event Date Category Type
12/04/2025 Notifications Pre Enforcement Notification



Upstream Natural Gas Venting & Flaring

The upstream natural gas venting & flaring volumes are sourced from upstream natural gas waste reports (C-115B) submissions.

Hide All Upstream Venting & Flaring 10/2021 10/2025
   Venting & Flaring Volumes Beneficial Use
Vented (MCF) Flared (MCF) Total (MCF) Used (MCF)
2021
October (first required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2022
January (second required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2023
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2024
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2025
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
Grand Total: 0 0 0 0

Orders Please login to review the orders associated with this well.

Production / Injection

The production & injection volumes are sourced from monthly production reports (C-115) submissions.

Hide All Production Export to Excel 12/1992 10/2025
   Production Injection
Time Frame Oil (BBLS) Gas (MCF) Water (BBLS) Days P/I Water (BBLS) Co2 (MCF) Gas (MCF) Other Pressure
1992 Cumulative
DOUBLE X;DELAWARE
Dec 22,060 56,487 3,200 99 0 0 0 0 0
Pool Total: 22,060 56,487 3,200 99 0 0 0 0 N/A
1993
DOUBLE X;DELAWARE
Jan 150 228 0 31 0 0 0 0 0
Feb 139 95 0 28 0 0 0 0 0
Mar 195 261 0 31 0 0 0 0 0
Apr 145 251 0 29 0 0 0 0 0
May 79 159 0 22 0 0 0 0 0
Jun 121 290 0 30 0 0 0 0 0
Jul 166 293 0 99 0 0 0 0 0
Aug 140 277 0 31 0 0 0 0 0
Sep 127 251 0 28 0 0 0 0 0
Oct 105 288 0 30 0 0 0 0 0
Nov 134 294 0 30 0 0 0 0 0
Dec 120 291 0 31 0 0 0 0 0
Pool Total: 1,621 2,978 0 420 0 0 0 0 N/A
1994
DOUBLE X;DELAWARE
Jan 127 296 380 31 0 0 0 0 0
Feb 105 262 343 28 0 0 0 0 0
Mar 124 294 294 31 0 0 0 0 0
Apr 105 279 285 30 0 0 0 0 0
May 30 141 294 20 0 0 0 0 0
Jun 151 197 285 29 0 0 0 0 0
Jul 145 181 294 31 0 0 0 0 0
Aug 121 285 294 29 0 0 0 0 0
Sep 126 280 276 30 0 0 0 0 0
Oct 105 230 285 31 0 0 0 0 0
Nov 104 242 270 20 0 0 0 0 0
Dec 134 306 280 31 0 0 0 0 0
Pool Total: 1,377 2,993 3,580 341 0 0 0 0 N/A
1995
DOUBLE X;DELAWARE
Jan 134 289 280 31 0 0 0 0 0
Feb 108 245 255 28 0 0 0 0 0
Mar 100 267 255 31 0 0 0 0 0
Apr 110 258 250 30 0 0 0 0 0
May 125 263 258 31 0 0 0 0 0
Jun 96 239 242 29 0 0 0 0 0
Jul 99 243 250 31 0 0 0 0 0
Aug 91 152 250 27 0 0 0 0 0
Sep 91 335 242 28 0 0 0 0 0
Oct 133 311 250 31 0 0 0 0 0
Nov 115 283 242 30 0 0 0 0 0
Dec 114 270 250 31 0 0 0 0 0
Pool Total: 1,316 3,155 3,024 358 0 0 0 0 N/A
1996
DOUBLE X;DELAWARE
Jan 145 238 250 31 0 0 0 0 0
Feb 84 231 234 29 0 0 0 0 0
Mar 67 270 250 29 0 0 0 0 0
Apr 105 254 250 30 0 0 0 0 0
May 99 250 258 31 0 0 0 0 0
Jun 88 238 258 27 0 0 0 0 0
Aug 104 173 267 31 0 0 0 0 0
Sep 93 1 250 29 0 0 0 0 0
Oct 112 6 208 31 0 0 0 0 0
Nov 95 42 148 30 0 0 0 0 0
Dec 86 21 133 31 0 0 0 0 0
Pool Total: 1,078 1,724 2,506 329 0 0 0 0 N/A
1997
DOUBLE X;DELAWARE
Jan 104 85 133 31 0 0 0 0 0
Feb 69 25 135 20 0 0 0 0 0
Mar 0 7 135 19 0 0 0 0 0
Apr 144 14 780 26 0 0 0 0 0
May 103 37 840 28 0 0 0 0 0
Jun 71 213 840 14 0 0 0 0 0
Jul 100 237 600 20 0 0 0 0 0
Aug 99 243 570 21 0 0 0 0 0
Sep 80 229 750 25 0 0 0 0 0
Oct 100 266 930 31 0 0 0 0 0
Nov 83 243 900 30 0 0 0 0 0
Dec 85 230 780 26 0 0 0 0 0
Pool Total: 1,038 1,829 7,393 291 0 0 0 0 N/A
1998
DOUBLE X;DELAWARE
Jan 96 225 900 30 0 0 0 0 0
Feb 54 199 570 19 0 0 0 0 0
Mar 140 208 930 31 0 0 0 0 0
Apr 53 130 720 24 0 0 0 0 0
May 0 20 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 26 30 1 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 343 808 3,150 105 0 0 0 0 N/A
1999
DOUBLE X;DELAWARE
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 36 105 780 26 0 0 0 0 0
Nov 47 295 870 29 0 0 0 0 0
Dec 48 261 750 25 0 0 0 0 0
Pool Total: 131 661 2,400 80 0 0 0 0 N/A
2000
DOUBLE X;DELAWARE
Jan 106 185 900 30 0 0 0 0 0
Feb 101 136 870 29 0 0 0 0 0
Mar 87 124 660 22 0 0 0 0 0
Apr 160 165 750 24 0 0 0 0 0
May 114 156 750 31 0 0 0 0 0
Jun 83 118 750 30 0 0 0 0 0
Jul 15 68 750 5 0 0 0 0 0
Aug 146 181 750 26 0 0 0 0 0
Sep 103 133 750 30 0 0 0 0 0
Oct 89 112 750 28 0 0 0 0 0
Nov 93 110 750 30 0 0 0 0 0
Dec 85 95 750 31 0 0 0 0 0
Pool Total: 1,182 1,583 9,180 316 0 0 0 0 N/A
2001
DOUBLE X;DELAWARE
Jan 96 115 750 30 0 0 0 0 0
Feb 67 77 750 21 0 0 0 0 0
Mar 82 96 750 29 0 0 0 0 0
Apr 83 78 750 29 0 0 0 0 0
May 78 81 750 31 0 0 0 0 0
Jun 70 79 750 30 0 0 0 0 0
Jul 54 76 250 14 0 0 0 0 0
Aug 73 77 250 0 0 0 0 0 0
Sep 24 26 250 30 0 0 0 0 0
Oct 59 0 250 19 0 0 0 0 0
Nov 73 0 250 28 0 0 0 0 0
Dec 46 0 250 18 0 0 0 0 0
Pool Total: 805 705 6,000 279 0 0 0 0 N/A
2002
DOUBLE X;DELAWARE
Jan 0 0 0 0 0 0 0 0 0
Feb 3 0 0 28 0 0 0 0 0
Mar 6 0 0 2 0 0 0 0 0
Apr 92 0 0 30 0 0 0 0 0
May 132 140 0 31 0 0 0 0 0
Jun 103 111 0 30 0 0 0 0 0
Jul 115 103 0 31 0 0 0 0 0
Aug 68 93 0 31 0 0 0 0 0
Sep 85 87 0 29 0 0 0 0 0
Oct 84 87 0 31 0 0 0 0 0
Nov 76 77 0 29 0 0 0 0 0
Dec 78 83 0 29 0 0 0 0 0
Pool Total: 842 781 0 301 0 0 0 0 N/A
2003
DOUBLE X;DELAWARE
Jan 86 75 0 30 0 0 0 0 0
Feb 69 65 0 28 0 0 0 0 0
Mar 62 72 0 31 0 0 0 0 0
Apr 135 80 0 30 0 0 0 0 0
May 27 68 0 31 0 0 0 0 0
Jun 62 50 0 31 0 0 0 0 0
Jul 20 54 0 31 0 0 0 0 0
Aug 67 49 0 31 0 0 0 0 0
Sep 55 56 0 31 0 0 0 0 0
Oct 66 47 0 19 0 0 0 0 0
Nov 92 100 0 30 0 0 0 0 0
Dec 61 84 0 29 0 0 0 0 0
Pool Total: 802 800 0 352 0 0 0 0 N/A
2004
DOUBLE X;DELAWARE
Jan 72 82 0 31 0 0 0 0 0
Feb 41 50 0 19 0 0 0 0 0
Mar 52 70 0 17 0 0 0 0 0
Apr 69 79 0 30 0 0 0 0 0
May 67 71 0 31 0 0 0 0 0
Jun 60 61 0 30 0 0 0 0 0
Jul 59 55 0 29 0 0 0 0 0
Aug 69 37 0 31 0 0 0 0 0
Sep 45 65 0 30 0 0 0 0 0
Oct 61 61 0 31 0 0 0 0 0
Nov 56 63 600 30 0 0 0 0 0
Dec 44 47 600 31 0 0 0 0 0
Pool Total: 695 741 1,200 340 0 0 0 0 N/A
2005
DOUBLE X;DELAWARE
Jan 73 76 600 31 0 0 0 0 0
Feb 30 24 600 28 0 0 0 0 0
Mar 33 26 600 31 0 0 0 0 0
Apr 37 91 600 30 0 0 0 0 0
May 75 56 600 31 0 0 0 0 0
Jun 57 56 600 30 0 0 0 0 0
Jul 59 50 600 30 0 0 0 0 0
Aug 40 42 400 20 0 0 0 0 0
Sep 53 44 400 23 0 0 0 0 0
Oct 41 50 200 13 0 0 0 0 0
Nov 68 73 200 30 0 0 0 0 0
Dec 69 63 200 28 0 0 0 0 0
Pool Total: 635 651 5,600 325 0 0 0 0 N/A
2006
DOUBLE X;DELAWARE
Jan 14 45 36 6 0 0 0 0 0
Feb 79 88 168 28 0 0 0 0 0
Mar 56 65 150 25 0 0 0 0 0
Apr 69 69 150 30 0 0 0 0 0
May 15 5 35 7 0 0 0 0 0
Jun 1 13 0 1 0 0 0 0 0
Jul 1 103 0 31 0 0 0 0 0
Aug 50 68 0 31 0 0 0 0 0
Sep 42 67 0 28 0 0 0 0 0
Oct 60 72 50 31 0 0 0 0 0
Nov 32 64 60 30 0 0 0 0 0
Dec 58 80 60 29 0 0 0 0 0
Pool Total: 477 739 709 277 0 0 0 0 N/A
2007
DOUBLE X;DELAWARE
Jan 47 95 60 31 0 0 0 0 0
Feb 60 63 60 28 0 0 0 0 0
Mar 31 64 60 31 0 0 0 0 0
Apr 49 95 60 30 0 0 0 0 0
May 72 83 60 31 0 0 0 0 0
Jun 47 95 60 31 0 0 0 0 0
Jul 33 53 60 22 0 0 0 0 0
Aug 42 79 60 28 0 0 0 0 0
Sep 45 73 60 30 0 0 0 0 0
Oct 40 100 620 31 0 0 0 0 0
Nov 27 38 600 30 0 0 0 0 0
Dec 21 64 620 31 0 0 0 0 0
Pool Total: 514 902 2,380 354 0 0 0 0 N/A
2008
DOUBLE X;DELAWARE
Jan 63 113 620 31 0 0 0 0 0
Feb 67 87 600 29 0 0 0 0 0
Mar 37 58 600 31 0 0 0 0 0
Apr 11 64 600 30 0 0 0 0 0
May 55 51 600 31 0 0 0 0 0
Jun 39 74 600 30 0 0 0 0 0
Jul 41 77 600 31 0 0 0 0 0
Aug 37 71 600 31 0 0 0 0 0
Sep 33 45 600 30 0 0 0 0 0
Oct 58 86 600 31 0 0 0 0 0
Nov 37 67 600 30 0 0 0 0 0
Dec 35 86 600 31 0 0 0 0 0
Pool Total: 513 879 7,220 366 0 0 0 0 N/A
2009
DOUBLE X;DELAWARE
Jan 21 73 600 31 0 0 0 0 0
Feb 49 63 600 28 0 0 0 0 0
Mar 36 73 600 31 0 0 0 0 0
Apr 33 69 600 30 0 0 0 0 0
May 36 67 600 31 0 0 0 0 0
Jun 0 61 600 15 0 0 0 0 0
Jul 20 62 600 31 0 0 0 0 0
Aug 23 66 600 31 0 0 0 0 0
Sep 30 53 600 30 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 17 51 600 30 0 0 0 0 0
Dec 36 87 600 31 0 0 0 0 0
Pool Total: 301 725 6,600 319 0 0 0 0 N/A
2010
DOUBLE X;DELAWARE
Jan 58 135 600 0 0 0 0 0 0
Feb 67 92 600 28 0 0 0 0 0
Mar 37 105 600 31 0 0 0 0 0
Apr 50 117 600 30 0 0 0 0 0
May 56 106 600 31 0 0 0 0 0
Jun 24 65 600 21 0 0 0 0 0
Jul 16 67 160 8 0 0 0 0 0
Aug 37 124 494 26 0 0 0 0 0
Sep 46 95 600 30 0 0 0 0 0
Oct 57 99 600 31 0 0 0 0 0
Nov 40 96 600 30 0 0 0 0 0
Dec 48 103 600 31 0 0 0 0 0
Pool Total: 536 1,204 6,654 297 0 0 0 0 N/A
2011
DOUBLE X;DELAWARE
Jan 52 97 600 31 0 0 0 0 0
Feb 25 46 600 18 0 0 0 0 0
Mar 18 107 600 31 0 0 0 0 0
Apr 58 121 600 30 0 0 0 0 0
May 46 131 600 30 0 0 0 0 0
Jun 35 117 600 30 0 0 0 0 0
Jul 20 118 600 31 0 0 0 0 0
Aug 21 75 440 22 0 0 0 0 0
Sep 38 103 600 25 0 0 0 0 0
Oct 52 136 600 31 0 0 0 0 0
Nov 67 124 600 30 0 0 0 0 0
Dec 49 139 600 31 0 0 0 0 0
Pool Total: 481 1,314 7,040 340 0 0 0 0 N/A
2012
DOUBLE X;DELAWARE
Jan 37 119 600 30 0 0 0 0 0
Feb 34 114 600 29 0 0 0 0 0
Mar 34 128 600 31 0 0 0 0 0
Apr 43 124 600 28 0 0 0 0 0
May 55 122 600 27 0 0 0 0 0
Jun 43 124 600 28 0 0 0 0 0
Jul 55 143 600 31 0 0 0 0 0
Aug 44 77 600 19 0 0 0 0 0
Sep 9 30 160 8 0 0 0 0 0
Oct 34 115 600 31 0 0 0 0 0
Nov 16 97 520 26 0 0 0 0 0
Dec 37 117 600 31 0 0 0 0 0
Pool Total: 441 1,310 6,680 319 0 0 0 0 N/A
2013
DOUBLE X;DELAWARE
Jan 25 90 460 23 0 0 0 0 0
Feb 40 115 560 28 0 0 0 0 0
Mar 30 20 120 6 0 0 0 0 0
Apr 70 0 440 22 0 0 0 0 0
May 35 2 600 31 0 0 0 0 0
Jun 42 0 600 22 0 0 0 0 0
Jul 37 0 600 30 0 0 0 0 0
Aug 23 0 600 29 0 0 0 0 0
Sep 33 0 600 30 0 0 0 0 0
Oct 32 0 600 31 0 0 0 0 0
Nov 66 0 600 30 0 0 0 0 0
Dec 44 0 600 24 0 0 0 0 0
Pool Total: 477 227 6,380 306 0 0 0 0 N/A
2014
DOUBLE X;DELAWARE
Jan 56 0 600 27 0 0 0 0 0
Feb 32 0 420 21 0 0 0 0 0
Mar 64 0 600 31 0 0 0 0 0
Apr 42 0 360 18 0 0 0 0 0
May 49 0 420 21 0 0 0 0 0
Jun 40 0 420 21 0 0 0 0 0
Jul 32 0 280 14 0 0 0 0 0
Aug 4 0 80 4 0 0 0 0 0
Sep 3 0 40 2 0 0 0 0 0
Oct 15 0 260 13 0 0 0 0 0
Nov 3 0 240 12 0 0 0 0 0
Dec 7 86 280 24 0 0 0 0 0
Pool Total: 347 86 4,000 208 0 0 0 0 N/A
2015
DOUBLE X;DELAWARE
Jan 24 164 100 5 0 0 0 0 0
Feb 14 59 220 11 0 0 0 0 0
Mar 4 0 80 4 0 0 0 0 0
Apr 33 110 600 30 0 0 0 0 0
May 6 15 100 5 0 0 0 0 0
Jun 18 166 500 25 0 0 0 0 0
Jul 8 18 100 5 0 0 0 0 0
Aug 34 6 300 15 0 0 0 0 0
Sep 23 148 400 20 0 0 0 0 0
Oct 23 148 400 20 0 0 0 0 0
Nov 53 194 540 27 0 0 0 0 0
Dec 26 50 220 11 0 0 0 0 0
Pool Total: 266 1,078 3,560 178 0 0 0 0 N/A
2016
DOUBLE X;DELAWARE
Jan 9 0 160 8 0 0 0 0 0
Feb 43 7 560 28 0 0 0 0 0
Mar 51 10 560 28 0 0 0 0 0
Apr 55 0 600 30 0 0 0 0 0
May 59 0 500 25 0 0 0 0 0
Jun 45 0 360 18 0 0 0 0 0
Jul 47 0 420 21 0 0 0 0 0
Aug 20 0 200 10 0 0 0 0 0
Sep 53 0 460 23 0 0 0 0 0
Oct 38 0 420 21 0 0 0 0 0
Nov 53 0 600 30 0 0 0 0 0
Dec 48 0 460 23 0 0 0 0 0
Pool Total: 521 17 5,300 265 0 0 0 0 N/A
2017
DOUBLE X;DELAWARE
Jan 49 0 440 20 0 0 0 0 0
Feb 35 0 300 15 0 0 0 0 0
Mar 51 10 560 28 0 0 0 0 0
Apr 49 0 480 24 0 0 0 0 0
May 56 0 480 24 0 0 0 0 0
Jun 68 0 600 30 0 0 0 0 0
Jul 48 0 600 31 0 0 0 0 0
Aug 43 0 600 31 0 0 0 0 0
Sep 1 0 300 15 0 0 0 0 0
Oct 1 0 20 1 0 0 0 0 0
Nov 30 0 300 15 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 431 10 4,680 234 0 0 0 0 N/A
2018
DOUBLE X;DELAWARE
Jan 34 0 280 14 0 0 0 0 0
Feb 12 0 100 5 0 0 0 0 0
Mar 7 0 60 3 0 0 0 0 0
Apr 10 0 160 8 0 0 0 0 0
May 3 0 60 3 0 0 0 0 0
Jun 25 0 340 17 0 0 0 0 0
Jul 61 0 540 29 0 0 0 0 0
Aug 40 0 400 20 0 0 0 0 0
Nov 34 0 750 0 0 0 0 0 0
Dec 56 0 750 0 0 0 0 0 0
Pool Total: 282 0 3,440 99 0 0 0 0 N/A
2019
DOUBLE X;DELAWARE
Jan 63 0 750 0 0 0 0 0 0
Feb 51 0 510 0 0 0 0 0 0
Mar 57 0 510 0 0 0 0 0 0
Apr 56 0 510 0 0 0 0 0 0
May 24 0 250 0 0 0 0 0 0
Jun 26 0 250 0 0 0 0 0 0
Jul 0 0 250 0 0 0 0 0 0
Aug 27 0 270 0 0 0 0 0 0
Sep 42 0 270 0 0 0 0 0 0
Oct 43 0 430 0 0 0 0 0 0
Nov 38 0 380 0 0 0 0 0 0
Dec 21 0 210 0 0 0 0 0 0
Pool Total: 448 0 4,590 0 0 0 0 0 N/A
2020
DOUBLE X;DELAWARE
Jan 2 0 2 0 0 0 0 0 0
Feb 17 0 2 0 0 0 0 0 0
Mar 60 0 600 0 0 0 0 0 0
Apr 49 0 600 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 1 0 10 0 0 0 0 0 0
Aug 0 0 1 1 0 0 0 0 0
Sep 0 0 1 1 0 0 0 0 0
Oct 0 0 1 1 0 0 0 0 0
Nov 0 0 1 1 0 0 0 0 0
Dec 0 0 1 1 0 0 0 0 0
Pool Total: 129 0 1,219 5 0 0 0 0 N/A
2021
DOUBLE X;DELAWARE
Jan 1 0 1 1 0 0 0 0 0
Feb 0 0 1 1 0 0 0 0 0
Mar 0 0 1 1 0 0 0 0 0
Apr 0 0 1 1 0 0 0 0 0
May 0 0 1 1 0 0 0 0 0
Jun 0 0 1 1 0 0 0 0 0
Jul 0 0 1 1 0 0 0 0 0
Aug 1 0 1 1 0 0 0 0 0
Sep 0 0 1 1 0 0 0 0 0
Oct 0 0 1 1 0 0 0 0 0
Nov 0 0 1 1 0 0 0 0 0
Dec 0 0 1 1 0 0 0 0 0
Pool Total: 2 0 12 12 0 0 0 0 N/A
2022
DOUBLE X;DELAWARE
Jan 0 0 1 1 0 0 0 0 0
Feb 0 0 1 1 0 0 0 0 0
Mar 0 0 1 1 0 0 0 0 0
Apr 0 0 1 1 0 0 0 0 0
May 0 0 1 1 0 0 0 0 0
Jun 97 0 1 30 0 0 0 0 0
Jul 0 0 1 30 0 0 0 0 0
Aug 69 0 1 31 0 0 0 0 0
Sep 0 0 1 1 0 0 0 0 0
Oct 0 0 1 1 0 0 0 0 0
Nov 0 0 1 1 0 0 0 0 0
Dec 0 0 1 1 0 0 0 0 0
Pool Total: 166 0 12 100 0 0 0 0 N/A
2023
DOUBLE X;DELAWARE
Jan 0 0 1 1 0 0 0 0 0
Feb 0 0 1 1 0 0 0 0 0
Mar 0 0 1 1 0 0 0 0 0
Apr 0 0 1 1 0 0 0 0 0
May 0 0 1 1 0 0 0 0 0
Jun 0 0 1 1 0 0 0 0 0
Jul 0 0 1 1 0 0 0 0 0
Aug 0 0 1 1 0 0 0 0 0
Sep 34 0 1 30 0 0 0 0 0
Oct 1 0 1 30 0 0 0 0 0
Nov 0 0 1 30 0 0 0 0 0
Dec 0 0 1 30 0 0 0 0 0
Pool Total: 35 0 12 128 0 0 0 0 N/A
2024
DOUBLE X;DELAWARE
Jan 0 0 1 1 0 0 0 0 0
Feb 34 0 1 17 0 0 0 0 0
Mar 14 0 1 12 0 0 0 0 0
Apr 8 0 1 8 0 0 0 0 0
May 24 0 1 31 0 0 0 0 0
Jun 24 0 1 2 0 0 0 0 0
Jul 1 0 1 2 0 0 0 0 0
Aug 1 0 1 1 0 0 0 0 0
Sep 1 0 1 1 0 0 0 0 0
Oct 1 0 1 1 0 0 0 0 0
Nov 114 0 1 30 0 0 0 0 0
Dec 123 0 1 30 0 0 0 0 0
Pool Total: 345 0 12 136 0 0 0 0 N/A
2025
DOUBLE X;DELAWARE
Jan 194 0 1 30 0 0 0 0 0
Feb 2 0 1 2 0 0 0 0 0
Mar 32 0 1 25 0 0 0 0 0
Apr 62 0 1 25 0 0 0 0 0
May 45 0 1 25 0 0 0 0 0
Jun 37 0 1 25 0 0 0 0 0
Jul 21 0 1,283 25 0 0 0 0 0
Aug 74 0 1,283 25 0 0 0 0 0
Sep 8 0 1,283 7 0 0 0 0 0
Oct 39 0 1,283 7 0 0 0 0 0
Pool Total: 514 0 5,138 196 0 0 0 0 N/A
Grand Total: 41,151 84,387 122,871 8,075 0 0 0 0 N/A


Transporters
Transporter Product Most Recent for Property
[15694] HF Sinclair Navajo Refining LLC Oil 10/2025
[15694] HF Sinclair Navajo Refining LLC Oil 6/2025

Points of Disposition
ID Type Description Pool(s)
2459450 Water [19090] DOUBLE X;DELAWARE
2459430 Gas [19090] DOUBLE X;DELAWARE
2459410 Oil [19090] DOUBLE X;DELAWARE
Click to go back to top of page