OCD Permitting

30-015-44634 CORRAL CANYON 36 25 FEDERAL COM #024H [320631]

General Well Information
[16696] OXY USA INC
Active
Oil
New
Horizontal
No
Federal
State
A-01-25S-29E      Lot: 1 940 FNL      1283 FEL
32.1639872,-103.9336013 NAD83
3135


Single
False


Proposed Formation and/or Notes



Depths

19381
19803
9156
19741


Formation Tops

Formation Top Producing Method Obtained
Rustler 519
Salado 985
Castile 1876
Delaware 3346
Bell Canyon 3372
Cherry Canyon 4284
Brushy Canyon 5646
Bone Spring 7187
1st Bone Spring Sand 8198
2nd Bone Spring Sand 9107

Event Dates

01/10/2018
01/18/2018


02/22/2018





12/03/2024

01/10/2020


01/16/2018




12/03/2024

History
Effective Date Property Well Number Operator C-101 Work Type Well Type Well Status Apd Cancelled Plug Date
01/18/2018 [320631] CORRAL CANYON 36 25 FEDERAL COM #024H [16696] OXY USA INC New Oil Active

Comments

Pits & Containments No Pits Found
Id Name Rule Status (Capacity) Type Registration
Inspection
Before *
Earliest Effective
Commencement
Last Effective
Cessation
Inspection
After *
Closure
Report
Reclamation
Report
Restoration
Complete

Casing

  Boreholes, Strings and Equipment Specifications Specifications for Strings and Tubing Strings Cemented and Intervals Cement and Plug Description
String/Hole Type Taper Date Set Diameter Top Bottom (Depth) Grade Length Weight Bot of Cem Top of Cem Meth Class of Cement Sacks Pressure Test (Y/N)
Hole 1 1 14.750 0 658 0 0.0 0 0 0 No
Surface Casing 1 10.750 0 658 J-55 658 45.5 658 0 Circ Unknown 762 No
Hole 2 1 9.875 658 8648 0 0.0 0 0 0 No
Intermediate 1 Casing 1 7.625 0 8648 L-80 8648 26.4 8648 0 Circ Unknown 1904 No
Hole 3 1 6.750 8648 19788 0 0.0 0 0 0 No
Production Casing 1 5.500 0 19788 P-110 19788 20.0 19788 0 Circ Unknown 867 No

Well Completions

[96473]  PIERCE CROSSING; BONE SPRING, EAST

Active
07/01/2025
B-25-24S-29E      195 FNL      2174 FEL

640     25-24S-29E Units: A B G H I J O P
36-24S-29E Units: A B G H I J O P

No

Flowing

Well Test Data

08/02/2018
0 psi
1.000 inches
2260.0 MCF
975 Kcf / bbl
Sold
24 hours
630 psi
Flowing
2317.0 bbls
0.0 Corr. API
2350.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth
05/04/2018 9772 19624 0 0

Notes


Event Dates

01/18/2018
06/01/2018

06/04/2018
04/27/2018
No
Yes
Yes
06/09/2018

06/01/2018
06/04/2018






09/04/2018

04/29/2018
Yes

06/09/2018

08/24/2018
08/30/2018


Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
06/01/2018 [320631] CORRAL CANYON 36 25 FEDERAL COM #024H [16696] OXY USA INC Active
01/18/2018 [320631] CORRAL CANYON 36 25 FEDERAL COM #024H [16696] OXY USA INC New, Not Drilled

Financial Assurance Please login to review the financial assurance associated with this well.

Compliance

Note that Financial Assurance and Inactive Well Compliance are documented in separate reports (Inactive Well Report, Financial Assurance Report).

Also note that some compliance issues are addressed at the operator level so not listed under each well.




Upstream Natural Gas Venting & Flaring

The upstream natural gas venting & flaring volumes are sourced from upstream natural gas waste reports (C-115B) submissions.

Hide All Upstream Venting & Flaring 10/2021 07/2025
   Venting & Flaring Volumes Beneficial Use
Vented (MCF) Flared (MCF) Total (MCF) Used (MCF)
2021
October (first required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 119 119 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 119 0 119 0
Annual Total: 119 0 119 0
2022
January (second required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 117 117 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 117 0 117 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 31 31 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 31 0 31 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 39 39 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 39 0 39 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 39 39 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 39 0 39 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
Annual Total: 466 0 466 0
2023
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 40 40 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 40 0 40 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 36 36 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 36 0 36 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 3 3 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 3 0 3 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 2 2 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 2 0 2 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 81 0 81 0
2024
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2025
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
Grand Total: 666 0 666 0

Orders Please login to review the orders associated with this well.

Production / Injection

The production & injection volumes are sourced from monthly production reports (C-115) submissions.

Hide All Production Export to Excel 6/2018 7/2025
   Production Injection
Time Frame Oil (BBLS) Gas (MCF) Water (BBLS) Days P/I Water (BBLS) Co2 (MCF) Gas (MCF) Other Pressure
2018
PIERCE CROSSING; BONE SPRING, EAST
Jun 27,846 31,916 305,922 30 0 0 0 0 0
Jul 35,436 65,510 82,604 31 0 0 0 0 0
Aug 31,191 37,819 131,812 31 0 0 0 0 0
Sep 14,140 31,304 127,928 24 0 0 0 0 0
Oct 21,030 34,008 51,628 31 0 0 0 0 0
Nov 11,577 14,652 35,814 23 0 0 0 0 0
Dec 7,207 13,345 24,742 15 0 0 0 0 0
Pool Total: 148,427 228,554 760,450 185 0 0 0 0 N/A
2019
PIERCE CROSSING; BONE SPRING, EAST
Jan 16,622 38,323 50,171 31 0 0 0 0 0
Feb 12,044 33,383 38,140 28 0 0 0 0 0
Mar 11,158 35,093 38,800 31 0 0 0 0 0
Apr 10,318 37,782 35,134 30 0 0 0 0 0
May 9,783 34,948 31,448 31 0 0 0 0 0
Jun 9,440 40,660 29,619 30 0 0 0 0 0
Jul 9,190 33,468 28,146 31 0 0 0 0 0
Aug 8,478 31,900 28,104 31 0 0 0 0 0
Sep 7,760 28,324 25,499 30 0 0 0 0 0
Oct 7,994 33,728 26,458 31 0 0 0 0 0
Nov 7,529 30,721 23,957 30 0 0 0 0 0
Dec 7,565 33,360 23,540 31 0 0 0 0 0
Pool Total: 117,881 411,690 379,016 365 0 0 0 0 N/A
2020
PIERCE CROSSING; BONE SPRING, EAST
Jan 6,833 29,373 21,803 31 0 0 0 0 0
Feb 5,950 25,884 18,295 29 0 0 0 0 0
Mar 5,968 26,281 19,389 31 0 0 0 0 0
Apr 5,443 24,709 18,113 30 0 0 0 0 0
May 5,220 25,912 18,279 31 0 0 0 0 0
Jun 4,840 24,943 17,228 30 0 0 0 0 0
Jul 4,720 23,643 16,797 31 0 0 0 0 0
Aug 4,665 23,183 16,769 31 0 0 0 0 0
Sep 4,723 22,194 15,895 30 0 0 0 0 0
Oct 4,670 21,159 15,815 31 0 0 0 0 0
Nov 4,446 18,634 13,585 30 0 0 0 0 0
Dec 4,481 19,773 14,363 31 0 0 0 0 0
Pool Total: 61,959 285,688 206,331 366 0 0 0 0 N/A
2021
PIERCE CROSSING; BONE SPRING, EAST
Jan 4,573 18,681 13,198 31 0 0 0 0 0
Feb 3,430 17,507 11,712 28 0 0 0 0 0
Mar 4,202 19,577 13,668 31 0 0 0 0 0
Apr 3,835 19,171 13,138 30 0 0 0 0 0
May 3,434 18,219 12,874 30 0 0 0 0 0
Jun 3,506 18,774 11,595 30 0 0 0 0 0
Jul 3,717 20,853 14,028 31 0 0 0 0 0
Aug 3,511 20,854 13,627 31 0 0 0 0 0
Sep 2,962 17,551 9,784 29 0 0 0 0 0
Oct 3,335 20,213 11,554 31 0 0 0 0 0
Nov 3,090 20,720 10,392 30 0 0 0 0 0
Dec 2,979 21,208 10,878 31 0 0 0 0 0
Pool Total: 42,574 233,328 146,448 363 0 0 0 0 N/A
2022
PIERCE CROSSING; BONE SPRING, EAST
Jan 3,073 20,539 10,548 31 0 0 0 0 0
Feb 2,748 17,635 9,481 28 0 0 0 0 0
Mar 2,813 19,551 9,908 31 0 0 0 0 0
Apr 2,745 19,550 9,151 30 0 0 0 0 0
May 2,628 18,935 10,116 31 0 0 0 0 0
Jun 2,703 19,028 10,742 26 0 0 0 0 0
Jul 3,902 27,178 15,893 31 0 0 0 0 0
Aug 3,354 17,414 13,125 31 0 0 0 0 0
Sep 2,747 15,918 10,079 30 0 0 0 0 0
Oct 3,407 20,135 10,647 31 0 0 0 0 0
Nov 3,830 26,667 12,906 30 0 0 0 0 0
Dec 3,847 28,090 14,057 31 0 0 0 0 0
Pool Total: 37,797 250,640 136,653 361 0 0 0 0 N/A
2023
PIERCE CROSSING; BONE SPRING, EAST
Jan 3,991 31,585 13,588 31 0 0 0 0 0
Feb 3,607 28,184 10,342 28 0 0 0 0 0
Mar 3,829 31,206 13,397 31 0 0 0 0 0
Apr 3,707 29,319 13,171 30 0 0 0 0 0
May 4,301 31,579 12,871 31 0 0 0 0 0
Jun 3,138 30,903 9,824 30 0 0 0 0 0
Jul 2,309 14,209 10,245 31 0 0 0 0 0
Aug 3,005 20,064 14,224 31 0 0 0 0 0
Sep 2,681 17,619 14,065 30 0 0 0 0 0
Oct 1,677 8,958 5,132 15 0 0 0 0 0
Nov 1,245 0 4,593 12 0 0 0 0 0
Dec 2,907 14,090 12,327 31 0 0 0 0 0
Pool Total: 36,397 257,716 133,779 331 0 0 0 0 N/A
2024
PIERCE CROSSING; BONE SPRING, EAST
Jan 2,452 16,319 12,680 31 0 0 0 0 0
Feb 1,936 10,725 9,625 29 0 0 0 0 0
Mar 1,893 6,524 10,183 31 0 0 0 0 0
Apr 2,966 13,489 12,837 30 0 0 0 0 0
May 2,447 8,839 10,933 31 0 0 0 0 0
Jun 2,259 16,720 12,369 30 0 0 0 0 0
Jul 1,873 9,160 11,603 30 0 0 0 0 0
Aug 1,153 6,310 3,600 22 0 0 0 0 0
Sep 2,152 5,550 9,384 29 0 0 0 0 0
Oct 2,449 5,981 11,212 31 0 0 0 0 0
Nov 2,229 9,525 7,783 30 0 0 0 0 0
Dec 1,943 20,456 5,867 29 0 0 0 0 0
Pool Total: 25,752 129,598 118,076 353 0 0 0 0 N/A
2025
PIERCE CROSSING; BONE SPRING, EAST
Jan 2,165 13,872 6,211 28 0 0 0 0 0
Feb 2,018 27,859 6,927 25 0 0 0 0 0
Mar 3,616 28,750 8,909 31 0 0 0 0 0
Apr 3,833 29,504 9,150 30 0 0 0 0 0
May 3,089 33,698 7,268 31 0 0 0 0 0
Jun 2,709 22,732 7,828 30 0 0 0 0 0
Jul 2,540 18,990 8,325 31 0 0 0 0 0
Pool Total: 19,970 175,405 54,618 206 0 0 0 0 N/A
Grand Total: 490,757 1,972,619 1,935,371 2,530 0 0 0 0 N/A


Transporters
Transporter Product Most Recent for Property
[16696] OXY USA INC Gas 7/2025
[151618] ENTERPRISE FIELD SERVICES L.L.C. Gas 7/2025
[241472] SOUTHERN UNION GAS SERVICES, LTD Gas 7/2025
[16696] OXY USA INC Oil 3/2025
[237722] ETP CRUDE LLC Oil 7/2025
[331550] INDECA Crude Xpress, LLC Oil 6/2023

Points of Disposition
ID Type Description Pool(s)
4032555 Gas CORRAL CANYON 36 25 FEDERAL COM #024H [96473] PIERCE CROSSING; BONE SPRING, EAST
4032554 Oil CORRAL CANYON 36 25 FEDERAL COM #024H [96473] PIERCE CROSSING; BONE SPRING, EAST
Click to go back to top of page