OCD Permitting

NAPP2201041627 2022 MAJOR I FLAR @ 0

General Incident Information

[fAPP2130541074] KO LANTA 9 CTB 3
[6137] DEVON ENERGY PRODUCTION COMPANY, LP
Inactive
Amended C-129 Accepted, Operator required to follow Monthly/Annual Waste Rule reporting requirements
Flare

N-09-23S-31E      386 FNL      98 FEL
32.314306,-103.783087 NAD83
Artesia
Federal
Eddy (15)


Severity Indicators














Notes

Industry Rep


Contact Details


Event Dates

01/06/2022
03:51 PM

01/06/2022
09:15 PM
1/21/2022

 

Incident Dates

19.15.29 NMAC - RELEASES

Type Action Received Denied Approved
Initial C-129 Report [72834] 01/17/2022 01/17/2022
Notification [71242] 01/10/2022 01/10/2022

19.15.30 NMAC - REMEDIATION

Type Action Received Denied Approved

Compositional Analysis of Vented and/or Flared Natural Gas

Date Methane
(CH4) %
Nitrogen
(N2) %
Hydrogen Suffide
(H2S) PPM
Carbon Dioxide
(CO2) %
Oxygen
(O2) %
Natural Gas Analysis 01/17/2022 73 2 0 3 0

Incident Materials

Cause Source Material Volume Units
Unk. Released Recovered Lost
Other (Specify) 0 0 0
High Line Pressure Gas Compressor Station Natural Gas Flared 833 0 833 Mcf
 
The concentration of dissolved chloride in the produced water >10,000 mg/l:           Yes           No        

Incident Events

Date Detail
01/17/2022 Corrective actions provided by the operator: Notified DCP.
01/17/2022 Primary Equipment identified by the operator (Gas Compressor Station)
01/17/2022 Steps taken to prevent waste provided by the operator: Notified DCP.
01/17/2022 Incident updated by the operator, upon the submission of a amendment for flaring of natural gas report.
01/17/2022 The (01/17/2022, C-129A) application [72834] was assigned to this incident.
01/10/2022 The (01/10/2022, NOMVF) application [71242] was assigned to this incident.
01/10/2022 New incident created by the operator, upon the submission of a notification of venting or flaring.
01/06/2022 The event discovered by the operator; will be tracked as a Flare till submission of the required subsequent C-129A.

Incident Severity
Major release as defined by 19.15.29.7(A) NMAC?
Yes No

Incident Corrective Actions






Orders No Orders Found