06/21/2023 |
The Remediation Plan is Conditionally Approved. The Variance Request for 500 ft2 floor confirmation sample size is approved. This includes the Release Area and the Overspray Area. Collect sidewall confirmation samples, representing no more than 200 ft2. Floor confirmation samples should be delineated/excavated to meet closure criteria standards for site assessment/characterization/proven depth to water determination. Sidewall/Edge samples should be delineated/excavated to 600 mg/kg for chlorides and 100 mg/kg for TPH to define the edge of the release. All samples must be analyzed for all constituents listed in Table I of 19.15.29.12 NMAC. The work will need to occur in 90 days after the work plan has been reviewed. |
06/21/2023 |
The (06/21/2023, C-141) application [188316] was accepted by OCD. The operator was emailed with details of this event. |
06/21/2023 |
An application [188316] was submitted to OCD for review. It was submitted, indicating that it was an: [C-141] Application for administrative approval of a release notification and corrective action The operator was emailed confirmation of this event. |
02/20/2023 |
The (06/21/2023, C-141) application [188316] was assigned to this incident. |
05/19/2022 |
The (05/19/2022, NOR) application [108416] was assigned to this incident. |
05/19/2022 |
Operator indicated that immediate notice was given (05/17/2022) prior to the submission of the NOR. |
05/19/2022 |
Initial Response question & answers at the time of notification were as follows. - The source of the release has been stopped: True.
- The impacted area has been secured to protect human health and the environment: True.
- Released materials have been contained via the use of berms or dikes, absorbent pads, or other containment devices: True.
- All free liquids and recoverable materials have been removed and managed appropriately: True.
|
05/19/2022 |
New incident created by the operator, upon the submission of notification of release. |
05/16/2022 |
C-141 received on 2/20/2023 for release on 05/16/2022. The cause of the release was reported as “Line was pinched causing it to rupture”. |
05/16/2022 |
Release discovered by the operator. |