OCD Permitting

NAPP2222558422 1900 MAJOR C FLAR @ 0

General Incident Information


[fAPP2123052765] HARVEST FOUR CORNERS GATHER SYSTEM
[373888] Harvest Four Corners, LLC
Cancellation Request Accepted, Cancelled
Flare

Aztec
Major

San Juan (45)

C-18-31N-11W      0 FNL      0 FEL
36.90547,-108.03525 NAD83


Notes

Industry Rep















Contact Details

Monica Smith
Environmental Specialist

Event Dates

12:20 PM

08/13/2022
1/16/1800

 

Incident Dates

Type Action Received Denied Approved
Cancellation Request [140178] 09/01/2022 09/01/2022
Notification [133742] 08/13/2022 08/13/2022

Compositional Analysis of Vented and/or Flared Natural Gas

No Compositional Analysis Found


Incident Materials

Cause Source Material Volume Units
Unk. Released Recovered Lost
Other (Specify) 0 0 0
 
The concentration of dissolved chloride in the produced water >10,000 mg/l:           Yes           No        

Incident Events

Date Detail
09/01/2022 The (09/01/2022, C-129C) application [140178] was assigned to this incident.
08/26/2022 Incident cancelled. Operator email stated, "Please accept this email as withdrawal of the notification of a potential major release. Gas loss calculations put the release at 31.6 mcf. Gas loss calculations have been attached". Line Leak Calc Orifice Diameter 0.125 inches Pressure 76 psig Time/date Discovered 8/12/2022 11:46 Time/date Isolated 8/13/2022 12:30 Total Hours Blown 24.73 hours Area of Orifice 0.012 sq. inches Lost Gas From Line Leak 29.371 Mcf Blowdown Calc Length 4,492 feet Actual Pipe OD 4.500 inches Wall Thickness 0.156 inches Pressure 76 psig Lost Gas From Blowdown 2.227 Mcf Total Gas Loss 31.60 Mcf Lost Gas=(Orifice Diameter)^2*Pressure*Time Blown Lost Gas=(Inside Diameter)^2*Pressure*Length*0.372/1000000
08/13/2022 The (08/13/2022, NOMVF) application [133742] was assigned to this incident.
08/13/2022 The event discovered by the operator; will be tracked as a Flare till submission of the required subsequent C-129A.
08/13/2022 New incident created by the operator, upon the submission of a notification of venting or flaring.

Incident Severity
Major release as defined by 19.15.29.7(A) NMAC?
Yes No

Incident Corrective Actions






Orders No Orders Found


Click to go back to top of page