OCD Permitting

NAPP2305255611 2023 MINOR I VENT @ 0

General Incident Information


[fAPP2123052765] HARVEST FOUR CORNERS GATHER SYSTEM
[373888] Harvest Four Corners, LLC
Initial C-129 Accepted, Operator required to follow Monthly/Annual Waste Rule reporting requirements
Vent

Aztec
Minor

San Juan (45)

J-35-31N-09W      0 FNL      0 FEL
36.853611,-107.746367 NAD83


Notes

Industry Rep















Contact Details


Event Dates

02/09/2023
04:00 AM

02/09/2023
08:30 AM
2/24/2023

 

Incident Dates

Type Action Received Denied Approved
Initial C-129 Report [188807] 02/21/2023 02/21/2023
Notification [188807] 02/21/2023 02/21/2023

Compositional Analysis of Vented and/or Flared Natural Gas

Date Methane
(CH4) %
Nitrogen
(N2) %
Hydrogen Suffide
(H2S) PPM
Carbon Dioxide
(CO2) %
Oxygen
(O2) %
Natural Gas Analysis 02/21/2023 81 0 0 17 0

Incident Materials

Cause Source Material Volume Units
Unk. Released Recovered Lost
Equipment Failure Pipeline (Any) Natural Gas Vented 57 0 57 Mcf
 
The concentration of dissolved chloride in the produced water >10,000 mg/l:           Yes           No        

Incident Events

Date Detail
02/21/2023 The (02/21/2023, C-129) application [188807] was assigned to this incident.
02/21/2023 Corrective actions provided by the operator: Pipeline was excavated and source of the release was identified. A weld in the pipeline had cracked. Damaged pipe was replaced, pipeline was buried, and placed back into service
02/21/2023 Primary Equipment identified by the operator (Pipeline (Any))
02/21/2023 Steps taken to prevent waste provided by the operator: The potential release was reported by a third-party operator at 4:00AM. This report was routed through the proper channels and Harvest personnel were dispatched to investigate. Immediately after confirming the leak, the pipeline was isolated to prevent further release of natural gas to atmosphere.
02/21/2023 New incident created by the operator, upon the submission of a venting of natural gas report.
02/09/2023 The venting of natural gas discovered by the operator.

Incident Severity
Major release as defined by 19.15.29.7(A) NMAC?
Yes No

Incident Corrective Actions






Orders No Orders Found


Click to go back to top of page