nRM2032828643 TT-1 LINE

General Incident Information

[fAPP2123031660] DCP SE NM Gathering System
[36785] DCP OPERATING COMPANY, LP
Active
Remediation Plan Approved, Pending submission of Remediation Closure Report from the operator
Release Other

P-22-22S-37E      0 FNL      0 FEL
32.37175,-103.14493 NAD83
Hobbs
Private
Lea (25)


Severity Indicators














Notes

Industry Rep
Referred to Environmental Inspector


Contact Details

Stephen W. Weathers

Event Dates

10/15/2020

10/30/2020

02/02/2022  

Incident Dates

19.15.29 NMAC - RELEASES

Type Action Received Denied Approved
Remediation Plan 04/09/2021 07/27/2021
Site Characterization 04/09/2021 07/27/2021
Initial C-141 Report 11/09/2020
Notification 11/09/2020

19.15.30 NMAC - REMEDIATION

Type Action Received Denied Approved

Compositional Analysis of Vented and/or Flared Natural Gas

No Compositional Analysis Found


Incident Materials

Cause Source Material Volume Units
Unk. Released Recovered Lost
Corrosion Pipeline (Any) [OBSOLETE] Natural Gas (Methane) 0 0 0 Mcf
Corrosion Pipeline (Any) Condensate 15 5 10 BBL
 
The concentration of dissolved chloride in the produced water >10,000 mg/l:           Yes           No        

Incident Events

Date Detail
11/05/2021 Your request for an extension to February 2nd, 2022 is approved.
07/27/2021 The (07/27/2021, C-141) application [23596] was accepted by OCD. The operator was emailed with details of this event.
07/27/2021 An application [23596] was submitted to OCD for review. It was submitted, indicating that it was an: [C-141] Application for administrative approval of a release notification and corrective action The operator was emailed confirmation of this event.
04/09/2021 The (07/27/2021, C-141) application [23596] was assigned to this incident.
11/23/2020 The (11/23/2020, C-141) application [11107] was accepted by OCD. The operator was emailed with details of this event.
11/23/2020 The (11/23/2020, C-141) application [11107] was assigned to this incident.
11/23/2020 An application [11107] was submitted to OCD for review. It was submitted, indicating that it was an: [C-141] Application for administrative approval of a release notification and corrective action The operator was emailed confirmation of this event.
10/15/2020 C-141 received on 11/9/2020 for release on 10/15/2020. The cause of the release was reported as “A leak was discovered due to internal corrosion causing a hole in the pipe. Operators were dispatched to shut in line. The line is isolated and has been shut down.”

Incident Severity
Major release as defined by 19.15.29.7(A) NMAC?
Yes No
From paragraph A. Major release determine using:
        (3) an unauthorized release of gases exceeding 500 MCF.

Incident Corrective Actions
No initial response data was found for this incident.

No site characterization data was found for this incident.

No remediation plan data was found for this incident.

No active remediation deferral request was found for this incident.

No remediation closure report data was found for this incident.

No reclamation report data was found for this incident.

No re-vegetation report data was found for this incident.

Orders No Orders Found