C-101 |
[C-101] EP Application for Permit to Drill (APD)
• Additionally referred to as: Electronic Permit Application for Permit to Drill (APD).
• File for well lease types, State and Private: Oil; Gas.
|
$500 fee required |
[C-101] Drilling Non-Federal/Indian (APD)
• Additionally referred to as: Application for a permit to drill, deepen, plug back or reenter a non-federal and non-indian well (APD).
• File for well lease types, State and Private: SWD-Injection; Plugback and recompletion to new zone; Deeping or Re-entry.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
APD |
Main Form |
True |
True |
|
C-102 (Plat) |
C-102 |
True |
True |
* Plat Survey (Pad Diagram) |
NGMP |
Natural Gas Management Plan |
False |
False |
* Introduced by NMCA 19.15.27.9 D |
Casing |
Additional Casing Information |
True |
True |
|
Dir Survey |
Directional Drilling Plan |
False |
False |
* Required for horizontal wells. |
H2S |
H2S Plan |
False |
False |
* Required only in a location where H2S present |
Closed Loop |
Closed Loop or Pit Plan |
True |
True |
|
Kick Off |
Kick-off Points |
False |
False |
|
Formation Tops |
Formation Tops |
True |
True |
|
Potash Notice |
Notice to POTASH leaseholders with one mile |
False |
False |
* See hearing order R-111-Q for details |
BOP |
Blow Out Prevention |
True |
True |
|
Plugging Plan |
Plugging Plan |
False |
False |
* If pilot hole is plugged |
|
$500 fee required |
[C-101] BLM - Federal/Indian Land Lease (Form 3160-3)
• Additionally referred to as: BLM - Application for Permit to Drill or Reenter (Federal and Indian Land leases) (Form 3160-3).
• File for all Federal approved APDs.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Federal 3160-3 |
Main Form |
True |
True |
|
C-102 (Plat) |
C-102 |
True |
True |
* Plat Survey (Pad Diagram) |
NGMP |
Natural Gas Management Plan |
True |
True |
* Introduced by NMCA 19.15.27.9 D |
Drilling/Casing |
Drilling and Casing Plan |
True |
True |
|
Dir Survey |
Directional Drilling Plan |
False |
False |
* Required for horizonal/directional wells |
Federal COA |
Federal Conditions of Approval |
False |
False |
|
H2S |
H2S Plan |
False |
False |
* Required only in a location where H2S present |
Closed Loop |
Closed Loop or Pit Plan |
True |
True |
|
Kick Off |
Kick-off Points |
False |
False |
|
Formation Tops |
Formation Tops |
True |
True |
|
Potash Notice |
Notice to POTASH leaseholders with one mile |
False |
False |
* See hearing order R-111-Q for details |
BOP |
Blow Out Prevention |
True |
True |
|
Plugging Plan |
Plugging Plan |
False |
False |
* If pilot hole is plugged |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (1) form C-101 - application for permit to drill, deepen or plug back;
19.15.7.12 APPLICATION FOR PERMIT TO DRILL, DEEPEN OR PLUG BACK (Form C-101): Form C-101 is the form an operator uses to apply for a permit to drill, deepen, re-enter or plug a well back to a different pool or complete or re-complete a well in an additional pool.
19.15.7.36 FORMS REQUIRED ON FEDERAL LAND:
A. An operator shall use federal forms in lieu of state forms when filing application for permit to drill, deepen or plug back and sundry notices and reports on wells and well completion or recompletion report and log for wells on federal lands in New Mexico. However, the operator shall submit two extra copies of each of the forms to the BLM, which, upon approval, will transmit the forms to the division. An operator of a well on federal land shall use the following BLM forms in lieu of division forms:
| BLM Form No. | Title of Form (Same for both agencies) | Form No. |
| 3160-3 (Nov. 1993) | Application for Permit to Drill, Deepen or Plug Back | C-101 |
| 3160-5 (Nov. 1983) | Sundry Notices and Reports on Wells | C-103 |
| 3160-4 (Nov. 1983) | Well Completion or Recompletion Report and Log | C-105 |
B. The above forms as the BLM may revise are the only forms that an operator may file in place of division forms.
C. After a well is completed and ready for pipeline connection, the operator shall file form C-104 along with a copy of form C-105 or BLM form No. 3160-4, whichever is applicable, with the division on wells drilled in the state, regardless of land status. Further, the operator shall file production reports using division forms; the division will not accept federal forms for reporting production.
D. An operator’s failure to comply with 19.15.7.36 NMAC shall result in the division’s cancellation of form C-104 for the affected well or wells.
|
C-102 |
[C-102] Well Location & Acreage Plat (C-102)
• Additionally referred to as: Well Location and Acreage Dedication Plat
(C-102).
• File for: Acreage change; amended C-102’s when required and not accompanied by a C-103.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-102 |
Main Form |
True |
True |
|
Dir Survey |
As Drilled-Directional Survey |
False |
False |
|
Kick Off |
Kick Off Point |
False |
False |
|
Formation Tops |
Formation Tops |
False |
False |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (2) form C-102 - well location and acreage dedication plat;
19.15.7.13 WELL LOCATION AND ACREAGE DEDICATION PLAT (Form C-102):
A. Form C-102 is a dual purpose form the operator uses to show the well’s exact location and the acreage dedicated to the well. The form is also used to show the ownership and status of each lease contained within the dedicated acreage. When there is more than one working interest or royalty owner on a given lease, designation of the majority owner et al. is sufficient.
B. An operator shall fill out and certify the information required on form C-102 except the well location on the plat. A professional surveyor, registered in the state of New Mexico, or surveyor approved by the division, shall plot and certify the well location on the plat from the section’s outer boundaries.
C. An operator shall file amended form C-102 in the event there is a change in the information the operator previously submitted. The operator does not need to provide certification of the well location when filing amended form C-102.
|
C-103 |
[NOTICESPUD] EP Notice of Spud (NoticeSpud)
• Additionally referred to as: Electronic Permit Notice of Spud (NoticeSpud).
• File for well lease types, State and Private.
|
|
[DRILLING] EP Drilling / Cement (Drilling)
• Additionally referred to as: Electronic Permit Drilling / Cement (Drilling).
• File for well lease types, State and Private.
|
|
[TUBING] EP Perforations / Tubing (Tubing)
• Additionally referred to as: Electronic Permit Perforations / Tubing (Tubing).
• File for well lease types, State and Private.
|
|
[C-103B] NOI APD Extension (C-103B)
• Additionally referred to as: NOI - APD Extension Request (C-103B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103B |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
|
|
[C-103A] NOI Change of Plans (C-103A)
• Additionally referred to as: NOI - Change of Plans for Drilling or Completion (C-103A).
• 19.15.7.14 A. Form C-103 as a notice of intention. (1) An operator shall file form C-103 and obtain the division’s approval prior to: (a) effecting a change of plans from those the division previously approved on form C-101 or form C-103; (b) altering a drilling well’s casing program or pulling casing or otherwise altering an existing well’s casing installation;
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103A |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
C-102 |
C-102 |
False |
False |
* With change of location or pool changes |
Plan Revision |
Plan Revision |
True |
True |
|
NGMP |
Natural Gas Management Plan |
False |
False |
* Introduced by NMCA 19.15.27.9 D |
BLM COA |
BLM Conditions Of Approval |
False |
False |
|
|
|
[C-103C] Sub. APD Cancellation (C-103C)
• Additionally referred to as: APD Cancellation (C-103C).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (i) other operations that affect the well’s original status but that are not specifically covered in 19.15.7.14 NMAC.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103C |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
|
|
[C-103E] NOI Recompletion (C-103E)
• Additionally referred to as: NOI - Work to Perform a Downhole Commingle or Re-Complete to add Completion (C-103E).
• 19.15.7.14 A. Form C-103 as a notice of intention. (1) An operator shall file form C-103 and obtain the division’s approval prior to: (c) making multiple completions in a well; (g) downhole commingling in well bores, within pools or areas that the division has established as pre-approved pools or areas.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103E |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
C-102 |
C-102 |
False |
False |
* Required when adding a new formation/zone |
Work Plan |
Work Plan |
True |
True |
|
Wellbore Schematic |
Wellbore Schematic |
False |
False |
|
NGMP |
Natural Gas Management Plan |
False |
False |
* Required when adding a zone or additional perforations |
BLM COA |
BLM Conditions Of Approval |
False |
False |
|
|
|
[C-103F] NOI Plug & Abandon (C-103F)
• Additionally referred to as: NOI - Plug & Abandon (C-103F).
• 19.15.7.14 A. Form C-103 as a notice of intention. (1) An operator shall file form C-103 and obtain the division’s approval prior to: (e) plugging and abandoning a well; • 19.15.7.14 A. Form C-103 as a notice of intention. (2) In the case of well plugging operations, the notice of intention shall include a detailed statement of the proposed work including plans for shooting and pulling casing; plans for mudding, including the mud’s weight; plans for cementing, including number of sacks of cement and depths of plugs; restoration and remediation of the location; and the time and date of the proposed plugging operations.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103F |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
Plugging Plan |
Plugging Plan |
True |
True |
|
Current Wellbore Schematic |
Current Wellbore Schematic |
True |
True |
|
Proposed Wellbore Schematic |
Proposed Wellbore Schematic |
True |
True |
|
BLM COA |
BLM Conditions Of Approval |
False |
False |
|
|
|
[C-103G] NOI Workover (C-103G)
• Additionally referred to as: NOI - Remedial Workover (C-103G).
• 19.15.7.14 A. Form C-103 as a notice of intention. (1) An operator shall file form C-103 and obtain the division’s approval prior to: (f) performing remedial work on a well that, when completed, will affect the well’s original status (this includes making new perforations in existing wells or squeezing old perforations in existing wells, but does not apply to new wells in the process of being completed nor to old wells being deepened or plugged back to another zone when the division has authorized the recompletion by an approved form C-101, application for permit to drill, re-enter, deepen plug back or add a zone, nor to acidizing, fracturing or cleaning out previously completed wells, nor to installing artificial lift equipment);
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103G |
Main Form |
True |
True |
|
Work Plan |
Work Plan |
True |
True |
|
Current Wellbore Schematic |
Current Wellbore Schematic |
True |
True |
|
Proposed Wellbore Schematic |
Proposed Wellbore Schematic |
True |
True |
|
|
|
[C-103H] Sub. Shut In (C-103H)
• Additionally referred to as: Subsequent Report - Shut In (C-103H).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (i) other operations that affect the well’s original status but that are not specifically covered in 19.15.7.14 NMAC.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103H |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
BLM COA |
BLM Conditions Of Approval |
False |
False |
|
|
|
[C-103I] NOI Temporary Abandonment (C-103I)
• Additionally referred to as: NOI - Temporary Abandonment (C-103I).
• 19.15.7.14 A. Form C-103 as a notice of intention. (1) An operator shall file form C-103 and obtain the division’s approval prior to: (d) placing a well in approved temporary abandonment;
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103I |
Main Form |
True |
True |
|
Work Plan |
Work Plan |
True |
True |
|
Current Wellbore Schematic |
Current Wellbore Schematic |
True |
True |
|
Proposed Wellbore Schematic |
Proposed Wellbore Schematic |
True |
True |
|
|
|
[C-103N] Sub. Drilling (C-103N)
• Additionally referred to as: Subsequent Report - Spud and Casing Report (C-103N).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (a) commencement of drilling operations; (b) casing and cement test;
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103N |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
|
|
[C-103P] Sub. Plugging (C-103P)
• Additionally referred to as: Subsequent Report - Plugging (C-103P).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (e) plugging and abandonment;
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103P |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
Plugging Report |
Plugging Report |
True |
True |
|
Wellbore Schematic |
Wellbore Schematic |
True |
True |
* Subsequent wellbore schematic needs to reflect downhole conditions and any adjustments made during plugging operations. If no changes were made from NOI refile previous wellbore schematic for completed P&A record. |
|
|
[C-103Q] Sub. Release After P&A (C-103Q)
• Additionally referred to as: Subsequent Location After P&A (C-103Q).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (i) other operations that affect the well’s original status but that are not specifically covered in 19.15.7.14 NMAC. • 19.15.7.14 F. Report on plugging of well. (2) The division shall not approve a plugging report until the operator demonstrates compliance with Subsection B of 19.15.25.10 NMAC.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Marker Photographs |
Marker Photographs |
True |
True |
|
Site Photographs |
Site Photographs |
False |
False |
|
Pipeline Layout |
Pipeline layout including legal description and surface ownership |
False |
False |
* Required if leaving pipeline(s) |
Radiation Survey |
Results of radiation survey along pipeline route |
False |
False |
* Required if leaving pipeline(s) |
Pipeline Material Type |
Type of material used the pipeline |
False |
False |
* Required if leaving pipeline(s) |
Pipeline Flushing Procedure |
Procedure used for flushing pipeline |
False |
False |
* Required if leaving pipeline(s) |
Explanation of Benefit |
Explanation why it is more beneficial to leave the pipeline |
False |
False |
* Required if leaving pipeline(s) |
Proof of Notice |
Proof notices sent to all surface owners where the pipeline is located |
False |
False |
* Required if leaving pipeline(s) |
|
|
[C-103R] Sub. Workover (C-103R)
• Additionally referred to as: Subsequent Report - Remedial Workover (C-103R).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (c) altering a well’s casing installation; (g) remedial work; (h) installation of artificial lifting equipment; • 19.15.7.14 G. Report of remedial work. ... The operator shall file the report on form C-103 and present a detailed account of the work done and the manner in which the operator performed the work; the daily production of oil, gas and water both prior to and after the remedial operation; the size and depth of shots; the quantity and type of crude, chemical or other materials the operator employed in the operation; and any other pertinent information. Among the remedial work an operator shall report on form C-103 are the following: (1) report on shooting, fluid fracturing or chemical treatment of a previously completed well; (2) report of squeeze job; (3) report on setting of liner or packer; (4) report of installation of pumping equipment or gas lift facilities; or (5) report of any other remedial operations that are not specifically covered herein.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103R |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
Work Plan |
Work Plan |
True |
True |
|
Pressure Test-Charts |
Pressure Test - Mechanical Integrity Chart |
False |
False |
* Required if casing changes |
Updated Wellbore Schematic |
Updated Wellbore Schematic |
False |
False |
* Required if casing changes |
|
|
[C-103T] Sub. (Re)Completion Sundry (C-103T)
• Additionally referred to as: Subsequent Report - Completion or Recompletion Sundry (C-103T).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (f) plugging back or deepening within the same pool;
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103T |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
Completion Work |
Completion Work |
True |
True |
|
Wellbore Schematic |
Wellbore Schematic |
False |
False |
|
|
|
[C-103U] Sub. Temporary Abandonment (C-103U)
• Additionally referred to as: Subsequent Report - Temporary Abandonment (C-103U).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (d) work to secure approved temporary abandonment; • 19.15.7.14 E. Report of temporary abandonment. The report shall present a detailed account of the work done on the well, including location and type of plugs used, if any, and status of surface and downhole equipment and any other pertinent information relative to the well’s overall status.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103U |
Main Form |
True |
True |
|
Work Plan |
Work Plan |
True |
True |
|
Pressure Test-Chart |
Pressure Test - Mechanical Integrity Chart |
True |
True |
|
Updated Wellbore Schematic |
Updated Wellbore Schematic |
True |
True |
|
|
|
[C-103V] Sub. For Delivery (C-103V)
• Additionally referred to as: Subsequent Report - For Delivery (C-103V).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as: (i) other operations that affect the well’s original status but that are not specifically covered in 19.15.7.14 NMAC.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103V |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
|
|
[C-103X] NOI General Sundry (C-103X)
• Additionally referred to as: NOI - General Sundry (C-103X).
• 19.15.7.14 A. Form C-103 as a notice of intention. (1) An operator shall file form C-103 and obtain the division’s approval prior to:
• Only use this form type when no other C-103 form type is available. If a determination is made that another C-103 form type is more appropriate, then the submission will be rejected.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103X |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
BLM COA |
BLM Conditions Of Approval |
False |
False |
|
|
|
[C-103Z] Sub. General Sundry (C-103Z)
• Additionally referred to as: Subsequent Report - General Sundry (C-103Z).
• 19.15.7.14 B. Form C-103 as a subsequent report. (2) The operator shall use form C-103 in reporting such completed operations as:
• Only use this form type when no other C-103 form type is available. If a determination is made that another C-103 form type is more appropriate, then the submission will be rejected.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-103Z |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-5 in lieu of division Form C-103 |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (3) form C-103 - sundry notices and reports on wells;
19.15.7.14 SUNDRY NOTICES AND REPORTS ON WELLS (Form C-103): Form C-103 is a dual purpose form the operator files with the appropriate division district office to obtain division approval prior to commencing certain operations and to report various completed operations.
A. Form C-103 as a notice of intention.
(1) An operator shall file form C-103 and obtain the division’s approval prior to:
(a) effecting a change of plans from those the division previously approved on form C-101 or form C-103;
(b) altering a drilling well’s casing program or pulling casing or otherwise altering an existing well’s casing installation;
(c) making multiple completions in a well;
(d) placing a well in approved temporary abandonment;
(e) plugging and abandoning a well;
(f) performing remedial work on a well that, when completed, will affect the well’s original status (this includes making new perforations in existing wells or squeezing old perforations in existing wells, but does not apply to new wells in the process of being completed nor to old wells being deepened or plugged back to another zone when the division has authorized the recompletion by an approved form C-101, application for permit to drill, re-enter, deepen plug back or add a zone, nor to acidizing, fracturing or cleaning out previously completed wells, nor to installing artificial lift equipment); or
(g) downhole commingling in well bores, within pools or areas that the division has established as pre-approved pools or areas.
(2) In the case of well plugging operations, the notice of intention shall include a detailed statement of the proposed work including plans for shooting and pulling casing; plans for mudding, including the mud’s weight; plans for cementing, including number of sacks of cement and depths of plugs; restoration and remediation of the location; and the time and date of the proposed plugging operations. The operator shall file a complete log of the well on form C-105 with the notice of intention to plug the well, if the operator has not previously filed the log (see 19.15.7.16 NMAC); the division shall not release the financial assurance until the operator complies with this requirement.
B. Form C-103 as a subsequent report.
(1) The operator shall file form C-103 as a subsequent report of operations in accordance with 19.15.7.14 NMAC as applicable to the particular operation being reported.
(2) The operator shall use form C-103 in reporting such completed operations as:
(a) commencement of drilling operations;
(b) casing and cement test;
(c) altering a well’s casing installation;
(d) work to secure approved temporary abandonment;
(e) plugging and abandonment;
(f) plugging back or deepening within the same pool;
(g) remedial work;
(h) installation of artificial lifting equipment; or
(i) other operations that affect the well’s original status but that are not specifically covered in 19.15.7.14 NMAC.
C. Report of commencement of drilling operations. Within 10 days following the commencement of drilling operations, the operator shall file a report of commencement on form C-103. The report shall indicate the hour and the date the operator spudded the well.
D. Report of results of test of casing and cement job; report of casing alteration. The operator shall file a report of casing and cement test within 10 days following the setting of each string of casing or liner. The operator shall file the report on form C-103 and include a detailed description of the test method employed and the results obtained by the test and any other pertinent information 19.15.16.10 NMAC requires. The report shall also indicate the top of the cement and the means by which the operator determined the top. It shall also indicate any changes from the casing program previously authorized for the well.
E. Report of temporary abandonment. The operator shall file a notice of work to secure approved temporary abandonment within 30 days following the work’s completion. The report shall present a detailed account of the work done on the well, including location and type of plugs used, if any, and status of surface and downhole equipment and any other pertinent information relative to the well’s overall status.
F. Report on plugging of well.
(1) The operator shall file a report of plugging operations within 30 days following completion of plugging operations on a well. The operator shall file the report on form C-103, which shall include the date the operator began plugging operations and the date the operator completed the work, a detailed account of the manner in which the operator performed the work including the depths and lengths of the various plugs set, the nature and quantities of materials employed in the plugging operations including the weight of the mud used, the size and depth of all casing left in the hole and any other pertinent information. (See 19.15.25 NMAC regarding plugging operations.)
(2) The division shall not approve a plugging report until the operator demonstrates compliance with Subsection B of 19.15.25.10 NMAC. The operator shall contact the appropriate division district office when the operator has restored the location in order to arrange for a division representative’s inspection of the plugged well and the location.
G. Report of remedial work. The operator shall file a report of remedial work performed on a well within 30 days following the work’s completion. The operator shall file the report on form C-103 and present a detailed account of the work done and the manner in which the operator performed the work; the daily production of oil, gas and water both prior to and after the remedial operation; the size and depth of shots; the quantity and type of crude, chemical or other materials the operator employed in the operation; and any other pertinent information. Among the remedial work an operator shall report on form C-103 are the following:
(1) report on shooting, fluid fracturing or chemical treatment of a previously completed well;
(2) report of squeeze job;
(3) report on setting of liner or packer;
(4) report of installation of pumping equipment or gas lift facilities; or
(5) report of any other remedial operations that are not specifically covered herein.
H. Report on deepening or plugging back within the same pool. An operator shall file a report of deepening or plugging back within 30 days following completion of the operations on a well. The operator shall file the report on form C-103 and present a detailed account of work done and the manner in which the operator performed the work. If the operator recompletes the well in the same pool, the operator shall also report the daily production of oil, gas and water both prior to and after recompletion. If the well is recompleted in another pool, the operator shall file forms C-101, C-102, C-104 and C-105 in accordance with 19.15.7.12 NMAC, 19.15.7.13 NMAC, 19.15.7.15 NMAC and 19.15.7.16 NMAC.
I. Other reports on wells. The operator shall submit reports on other operations that affect the well’s original status but that are not specifically covered in 19.15.7.14 NMAC to the division on form C-103 10 days following the operation’s completion.
19.15.7.36 FORMS REQUIRED ON FEDERAL LAND:
A. An operator shall use federal forms in lieu of state forms when filing application for permit to drill, deepen or plug back and sundry notices and reports on wells and well completion or recompletion report and log for wells on federal lands in New Mexico. However, the operator shall submit two extra copies of each of the forms to the BLM, which, upon approval, will transmit the forms to the division. An operator of a well on federal land shall use the following BLM forms in lieu of division forms:
| BLM Form No. | Title of Form (Same for both agencies) | Form No. |
| 3160-3 (Nov. 1993) | Application for Permit to Drill, Deepen or Plug Back | C-101 |
| 3160-5 (Nov. 1983) | Sundry Notices and Reports on Wells | C-103 |
| 3160-4 (Nov. 1983) | Well Completion or Recompletion Report and Log | C-105 |
B. The above forms as the BLM may revise are the only forms that an operator may file in place of division forms.
C. After a well is completed and ready for pipeline connection, the operator shall file form C-104 along with a copy of form C-105 or BLM form No. 3160-4, whichever is applicable, with the division on wells drilled in the state, regardless of land status. Further, the operator shall file production reports using division forms; the division will not accept federal forms for reporting production.
D. An operator’s failure to comply with 19.15.7.36 NMAC shall result in the division’s cancellation of form C-104 for the affected well or wells.
|
C-104 |
[C-104] Completion Packet - Test Allowable (C-104RT)
• Additionally referred to as: “Completion Packet” for C-104 Test Allowable or C-104 Request to Test (C-104RT).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-104RT |
Main Form |
True |
True |
* Current OCD C-104 form |
C-102 |
C-102 As Drilled |
False |
False |
* Required "As Drilled" Plat for horizontal/directional wells |
Directional Survey |
As Drilled-Directional Survey |
False |
False |
* Required for horizontal/directional wells |
Deviation Survey |
Deviation Survey |
False |
False |
* Required for vertical wells |
|
|
[C-104] Completion Packet - New Well (C-104NW)
• Additionally referred to as: C-104 New Well or C-104 Recomplete (C-104NW).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-104NW/RC |
Main Form |
True |
True |
* Current OCD C-104 form |
C-102 |
C-102 As Drilled |
True |
True |
* Required "As Drilled" Plat for horizontal/directional wells |
Directional Survey |
As Drilled-Directional Survey |
False |
False |
* Required for horizontal/directional wells |
Deviation Survey |
Deviation Survey |
False |
False |
* Required for vertical wells |
C-105 |
C-105 |
True |
True |
* Current OCD C-105 form, or approved BLM equivalent |
Wellbore Schematic |
Wellbore Schematic |
False |
False |
* Detailed wellbore schematic for New Completions |
C-103 |
C-103 Misc |
False |
False |
|
BLM Form |
BLM Approved Forms |
False |
False |
|
|
|
[C-104] Completion Packet - Tight Hole/Confidential (C-104CT)
• Additionally referred to as: C-104 Confidential Packet (C-104CT).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-104CT |
Main Form |
True |
True |
* Current OCD C-104 form |
Request Confidential Status |
Request for “Tight Hole” Confidential status |
True |
True |
* File per NMAC 19.15.7.16 C. Special processing directives to be put in place |
C-102 |
C-102 As Drilled |
True |
True |
* Required "As Drilled" Plat for horizontal/directional wells |
Directional Survey |
As Drilled-Directional Survey |
False |
False |
* Required for horizontal/directional wells |
Deviation Survey |
Deviation Survey |
False |
False |
* Required for vertical wells |
C-105 |
C-105 |
True |
True |
* Current OCD C-105 form, or approved BLM equivalent |
Wellbore Schematic |
Wellbore Schematic |
False |
False |
|
C-103 |
C-103 Misc |
False |
False |
|
BLM Form |
BLM Approved Forms |
False |
False |
|
|
|
[C-104] Transport Authorization (C-104)
• Additionally referred to as: Request for Allowable and Authorization to Transport (C-104).
• This form is no longer being accepted by the OCD. Use the appropriate variant from above after (07/01/2024).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-104 |
Main Form |
True |
True |
|
|
|
[C-104] Completion Packet (C-104C)
• Additionally referred to as: Request for Allowable and Authorization to Transport, Completion Packet (C-104C).
• This form is no longer being accepted by the OCD. Use the appropriate variant from above after (07/01/2024).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-104C |
Main Form |
True |
True |
|
C-102 |
C-102 |
False |
False |
* Required "As Drilled" Plat for horizontal/directional wells |
Directional Survey |
As Drilled-Directional Survey |
False |
False |
* Required for horizontal/directional wells |
Deviation Survey |
Deviation Survey |
False |
False |
* Required for vertical wells |
Kick Off |
Kick-off Points |
False |
False |
|
C-103 |
C-103 Completion Sundry |
False |
False |
|
C-105 |
C-105 |
False |
False |
|
Wellbore Schematic |
Wellbore Schematic |
False |
False |
|
C-103 |
C-103 Misc |
False |
False |
* File for: additional completion information if it was not provided on completion sundry; i.e. tubing-well test data; 1st delivery notice |
|
|
[C-104] Tight Hole Completion Packet (C-104CT)
• Additionally referred to as: Request for Allowable and Authorization to Transport, Confidential “Tight Hole” Completion Packet (C-104CT).
• This form is no longer being accepted by the OCD. Use the appropriate variant from above after (07/01/2024).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-104CT |
Main Form |
True |
True |
|
Request Confidential Status |
Request for Confidential “Tight Hole” status |
True |
True |
* File per NMAC 19.15.7.16 C. Special processing directives to be put in place |
C-102 |
C-102 |
False |
False |
* Required "As Drilled" Plat for horizontal/directional wells |
Directional Survey |
As Drilled-Directional Survey |
False |
False |
* Required for horizontal/directional wells |
Deviation Survey |
Deviation Survey |
False |
False |
* Required for vertical wells |
Kick Off |
Kick-off Points |
True |
True |
|
C-103 |
C-103 Completion Sundry |
True |
True |
|
C-105 |
C-105 |
True |
True |
|
Wellbore Schematic |
Wellbore Schematic |
True |
True |
|
C-103 |
C-103 Misc |
False |
False |
* File for: additional completion information if it was not provided on completion sundry; i.e. tubing-well test data; 1st delivery notice |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (4) form C-104 - request for allowable and authorization to transport oil and gas;
19.15.7.15 REQUEST FOR ALLOWABLE AND AUTHORIZATION TO TRANSPORT OIL AND GAS (Form C-104): An operator shall file with the division a complete form C-104 to request the division assign an allowable to a newly completed or re-completed well or a well completed in an additional pool or issue an operator authorization to transport oil or gas from the well.
19.15.7.16 WELL COMPLETION OR RECOMPLETION REPORT AND LOG (Form C-105):
C. The division shall not keep form C-105 and accompanying attachments confidential unless the well’s owner requests in writing that the division keep it confidential. Upon such request, the division shall keep these data confidential for 90 days from the date of the well’s completion, provided, however, that the report, logs and other attached data may, when pertinent, be introduced in a public hearing before division examiners, the commission or in a court of law, regardless of the request that they be kept confidential.
19.15.16.14 DEVIATION TESTS AND WELLBORE SURVEYS; VERTICAL, DEVIATED AND DIRECTIONAL WELLS:
A. Vertical and deviated well bores.
(1) Deviation tests required. An operator shall test a vertical or deviated well that is drilled or deepened at reasonably frequent intervals to determine the deviation from the vertical. The operator shall make the tests at least once each 500 feet or at the first bit change succeeding 500 feet. The operator shall file with the division along with its form C-104 a tabulation of deviation tests run that is sworn to and notarized.
(2) Excessive deviation. When the deviation averages more than five degrees in a 500-foot interval, the operator shall include the calculations of the hole’s maximum possible horizontal displacement. When the maximum possible horizontal displacement exceeds the distance to the appropriate unit’s nearest outer boundary line the operator shall run a directional survey to establish the location of the well’s completed interval.
(3) Unorthodox well locations. If the results of the directional survey of a vertical or deviated well indicate that the completed interval is more than 50 feet from the approved surface location and closer than the minimum setback requirements to the applicable unit’s outer boundary, then the well is considered unorthodox. To obtain authority to produce the well, the operator shall file an application with the division’s Santa Fe office, and shall follow the process outlined in Subsection C of 19.15.15.13 NMAC to obtain approval of the unorthodox well location.
(4) Directional survey requirements. Upon the director’s request, the operator shall directionally survey a vertical or deviated well. The operator shall file directional surveys run on a well, in division-approved format, with the division upon the well’s completion. The division shall not approve a form C-104 for the well until the operator has filed the directional surveys.
B. Directional well bores.
(1) Directional drilling. The appropriate division district office may grant a permit to directionally drill a well bore if every point of the completed interval is projected to be located at a distance greater than or equal to the minimum setback distance from the applicable spacing unit’s outer boundaries or at an unorthodox well location the division previously approved.
(2) Unorthodox well locations. If all or part of a directional well’s completed interval is projected to be located less than the minimum distance from the outer boundary of the well’s spacing unit, the well’s location is considered unorthodox. To obtain approval for the well’s location, the operator shall file an application in the division’s Santa Fe office in accordance with Subsection C of 19.15.15.13 NMAC.
(3) Directional surveys required. An operator shall run a directional survey on each well drilled pursuant to Subsection B of 19.15.16.14 NMAC. The operator shall file a directional survey, in division-approved format, with the division upon the well’s completion. The division shall not approve a form C-104 for the well until the operator files the directional survey. The well’s location will be considered unorthodox if the directional survey indicates that part of a well’s completed interval, as drilled, is located more than 50 feet from its projected location and closer to an outer boundary of the spacing unit than applicable minimum setback distance. For previously approved unorthodox well locations, the well’s as-drilled location is unorthodox if the directional survey indicates that any part of the completed interval is located more than 50 feet (or, if less, twenty-five percent of the previously authorized distance) closer to the outer boundary of the spacing unit than the approved location.
C. Directional survey specifications. Directional surveys that 19.15.16.14 NMAC requires shall have shot points no more than 200 feet apart and shall be run by competent surveying companies. The division shall allow exceptions to the minimum shot point spacing provided the survey’s accuracy is still within acceptable limits.
19.15.16.15 HORIZONTAL WELLS:
E. Other matters.
(1) Directional survey requirements. The operator of each horizontal well shall run a directional survey and file the directional survey, in a division-approved format, upon the well’s completion. Directional surveys shall have shot points no more than 200 feet apart and shall be run by competent surveying companies. The division shall allow exceptions to the minimum shot point spacing provided the survey’s accuracy is still within acceptable limits. The division shall not approve a form C-104 for the well until the operator has filed the required directional survey.
19.15.16.16 MULTIPLE COMPLETIONS; BRADENHEAD GAS WELLS:
A. Multiple completions.
(1) Filing. An operator intending to multiple complete shall file form C-101 or C-103 with the division for approval before completing and C-104 after completing along with information required by the form instructions.
19.15.16.20 ALLOWABLES AND AUTHORIZATION TO TRANSPORT OIL AND GAS:
A. The division may assign an allowable to a newly completed or re-completed well or a well completed in an additional pool or issue an operator authorization to transport oil or gas from the well if the operator:
(1) has filed a complete form C-104;
(2) has provided a sworn and notarized tabulation of all deviation tests the operator has run on the well, and directional surveys with calculated bottom hole location, in accordance with the requirements of 19.15.16.14 NMAC or 19.15.16.15 NMAC;
(3) has dedicated a standard spacing unit or horizontal spacing unit for the pool in which the well is completed, a standard spacing unit or horizontal spacing unit has been communitized or pooled and dedicated to the well or the division has approved a non-standard spacing unit or horizontal spacing unit; and
(4) complies with Subsection A of 19.15.5.9 NMAC.
B. The allowable the division assigns to an oil well is effective at 7:00 a.m. on the completion date, provided the division receives form C-104 during the month of completion. The date of completion shall be that date when new oil is delivered into the stock tanks. Unless otherwise specified by special pool orders, the allowable the division assigns to a gas well is effective at 7:00 a.m. on the date of connection to a gas transportation facility, as evidenced by an affidavit of connection from the transporter to the division, or the date of receipt of form C-104 by the division, whichever date is later.
19.15.18.19 GATHERING, TRANSPORTING AND SALE OF DRIP:
A. The waste of drip is prohibited when it is economically feasible to salvage the drip.
B. A person may move and sell drip, provided it complies with 19.15.18.19 NMAC.
C. A person shall not transport or sell drip until the gas transporter files form C-104 designating the drip transporter authorized to remove the drip from its gas gathering or transportation system.
19.15.23.8 DOCUMENTATION REQUIRED:
A. Off-lease transportation of oil or lease condensate by motor vehicle shall be pursuant to an approved form C-104 and shall be accompanied by a run ticket or equivalent document. The documentation shall identify the transporter’s name and address, the operator’s name, the name of the lease or facility from which the oil was taken, the date of removal, the API gravity of the oil, the observed percentage of BS&W, the volume of oil or opening and closing tank gauges or meter readings and the driver’s signature. The document shall provide space for recording of the lease number and for the signature of the operator or the operator’s representative.
19.15.24.11 PRODUCTION OF LIQUID HYDROCARBONS FROM GAS WELLS:
A. Liquid hydrocarbons produced incidental to the authorized production of gas from a well the division has classified as a gas well are legal production.
B. For purposes of 19.15.24.11 NMAC the division shall consider gas produced from a gas well to be authorized production with the following exceptions:
(1) when the operator produces the well without an approved form C-104, designating the gas transporter and the oil or condensate transporter for the well; or
(2) when the division has directed the operator to shut-in the well.
C. In the event the division directs an operator to shut-in a gas well, the operator and the division shall immediately notify both the gas transporter and oil transporter.
|
C-105 |
[C-105] Well (Re)Completion (C-105)
• Additionally referred to as: Well Completion or Recompletion Report (C-105).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-105 |
Main Form |
True |
True |
* An operator of a well on federal land shall use the BLM Form 3160-4 in lieu of division Form C-105 |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (5) form C-105 - well completion or recompletion report and log;
19.15.7.16 WELL COMPLETION OR RECOMPLETION REPORT AND LOG (Form C-105):
A. Within 45 days following the completion or recompletion of a well, the operator shall file form C-105 with the appropriate division district office accompanied by a summary of special tests conducted on the well, including drill stem tests. In addition, the operator shall file a copy of electrical and radio-activity logs run on the well with form C-105. If the division does not receive form C-105 with attached logs and summaries within the specified 45-day period, the division shall withhold the allowable for the well until the operator has complied with 19.15.7.16 NMAC.
B. In the case of a dry hole, a complete record of the well on form C-105 with the attachments listed in Subsection A of 19.15.7.16 NMAC shall accompany the notice of intention to plug the well, unless previously filed. The division shall not approve the plugging report or release the bond the operator has complied with 19.15.7.16 NMAC.
C. The division shall not keep form C-105 and accompanying attachments confidential unless the well’s owner requests in writing that the division keep it confidential. Upon such request, the division shall keep these data confidential for 90 days from the date of the well’s completion, provided, however, that the report, logs and other attached data may, when pertinent, be introduced in a public hearing before division examiners, the commission or in a court of law, regardless of the request that they be kept confidential.
19.15.7.36 FORMS REQUIRED ON FEDERAL LAND:
A. An operator shall use federal forms in lieu of state forms when filing application for permit to drill, deepen or plug back and sundry notices and reports on wells and well completion or recompletion report and log for wells on federal lands in New Mexico. However, the operator shall submit two extra copies of each of the forms to the BLM, which, upon approval, will transmit the forms to the division. An operator of a well on federal land shall use the following BLM forms in lieu of division forms:
| BLM Form No. | Title of Form (Same for both agencies) | Form No. |
| 3160-3 (Nov. 1993) | Application for Permit to Drill, Deepen or Plug Back | C-101 |
| 3160-5 (Nov. 1983) | Sundry Notices and Reports on Wells | C-103 |
| 3160-4 (Nov. 1983) | Well Completion or Recompletion Report and Log | C-105 |
B. The above forms as the BLM may revise are the only forms that an operator may file in place of division forms.
C. After a well is completed and ready for pipeline connection, the operator shall file form C-104 along with a copy of form C-105 or BLM form No. 3160-4, whichever is applicable, with the division on wells drilled in the state, regardless of land status. Further, the operator shall file production reports using division forms; the division will not accept federal forms for reporting production.
D. An operator’s failure to comply with 19.15.7.36 NMAC shall result in the division’s cancellation of form C-104 for the affected well or wells.
19.15.16.19 LOG, COMPLETION AND WORKOVER REPORTS:
A. Completion report. Within 45 days after the completion of a well drilled for oil or gas, or the recompletion of a well into a different common source of supply, the operator shall file a completion report with the division on form C-105. For the purpose of 19.15.16.19 NMAC, a hole drilled or cored below fresh water or that penetrates oil- or gas-bearing formations or that an owner drills is presumed to be a well drilled for oil or gas. The operator shall signify on form C-105, or alternatively on form C-103, whether the well has been hydraulically fractured.
B. Hydraulic fracture disclosure. For a hydraulically fractured well, the operator shall also complete and file with the FracFocus chemical disclosure registry a completed hydraulic fracturing disclosure within 45 days after completion, recompletion or other hydraulic fracturing treatment of the well. The hydraulic fracturing disclosure shall be completed on a then current edition of the hydraulic fluid product component information form published by FracFocus and shall include complete and correct responses disclosing all information called for by the FracFocus form, provided that:
(1) the division does not require the reporting of information beyond the material safety data sheet data as described in 29 C.F.R. 1910.1200;
(2) the division does not require the reporting or disclosure of proprietary, trade secret or confidential business information; and
(3) the division shall download and archive New Mexico FracFocus submissions on a quarterly basis.
C. If the FracFocus chemical disclosure registry is temporarily inoperable, the operator of a well on which hydraulic fracturing treatment(s) were performed shall file the information required by the then most recent FracFocus form with the division along with Well Completion Report (form C-105) or Sundry Notice (form C-103) reporting the hydraulic fracture treatment and file the information on the FracFocus internet website when the website is again operable. If the FracFocus chemical disclosure registry is discontinued or becomes permanently inoperable, the operator shall continue filing the information with the division until otherwise provided by rule or order.
19.15.26.8 INJECTION OF FLUIDS INTO RESERVOIRS:
G. Storage wells.
(1) The director may grant administratively, without hearing, an application for the underground storage of liquefied petroleum gas or liquid hydrocarbons in secure caverns within massive salt beds, provided the applicant has complied with the notice provisions of Subsection B of 19.15.26.8 NMAC and the division receives no objections pursuant to Subsection C of 19.15.26.8 NMAC.
(2) In addition to the filing requirements of Subsection B of 19.15.26.8 NMAC, the applicant for approval of a storage well under Subsection G of 19.15.26.8 NMAC shall file the following:
(a) with the director, financial assurance in accordance with the provisions of 19.5.8 NMAC; and
(b) with the appropriate division district office:
(i) form C-101;
(ii) form C-102; and
(iii) form C-105.
|
C-106 |
[C-106] NOI Utilize ACTE (C-106)
• Additionally referred to as: Notice of Intention to Utilize Automatic Custody Transfer Equipment (C-106).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-106 |
Main Form |
True |
True |
|
Facility Diagram |
Facility Diagram |
False |
True |
|
Compliance Plan |
Compliance Plan |
False |
True |
|
Well Plat |
Well Plat |
False |
True |
|
C-102 |
C-102 |
False |
True |
* For included wells |
Wellsite Diagram |
Wellsite Diagram |
False |
True |
|
Midstream Approval Evidence |
Evidence of Approval from Midstream |
False |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (6) form C-106 - notice of intention to utilize automatic custody transfer equipment;
19.15.7.17 NOTICE OF INTENTION TO UTILIZE AUTOMATIC CUSTODY TRANSFER EQUIPMENT (Form C-106): An operator intending to use an ACT system shall file form C-106, when applicable, in accordance with Subsection A of 19.15.18.15 NMAC.
|
C-107 |
[C-107] Down Hole Commingle (C-107A)
• Additionally referred to as: Application for administrative approval of a downhole commingle (C-107A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-107A |
Main Form |
True |
True |
|
Summary |
Summary of proposal |
True |
True |
|
Current Well Diagram |
Current Well Diagram |
True |
True |
|
Proposed Well Diagram |
Proposed Well Diagram |
True |
True |
* After proposed alterations |
Proposed Allocation |
Proposed Allocation and Supporting Data |
True |
True |
* Depending on allocation method |
Commingling Statement |
Commingling will Not Reduce Value Statement |
True |
True |
* Statement that commingling will not reduce the total remaining production's value |
Notified Persons w/ Tracking |
List of Notified Persons and Tracking Numbers |
False |
True |
* Required if ownership is diverse as defined by 19.15.12.7(A) NMAC |
No Protests Statement |
No Received Protests Statement |
False |
False |
* Required if ownership is diverse as defined by 19.15.12.7(A) NMAC |
Identical Ownership Statement |
Identical Ownership Statement |
False |
False |
* Required if ownership is identical as defined by 19.15.12.7(B) NMAC |
Proof of BLM/SLO Notice |
Proof of BLM/SLO Notice |
False |
False |
* Required if Federal or State lands are involved |
Gas Sample |
Gas Sample |
False |
False |
* Required if pools are not commonly commingled |
Water Sample |
Water Sample |
False |
False |
* Required if pools are not commonly commingled |
Administrative Checklist |
Administrative Application Checklist |
False |
False |
* Department Use Only Attachment |
Correspondence |
Correspondence |
False |
False |
* Department Use Only Attachment |
OCD Review |
OCD Review |
False |
False |
* Department Use Only Attachment |
Signed Order |
Signed Order |
False |
True |
* Department Use Only Attachment |
|
$150 fee required |
[C-107] Surface Commingle or Off-Lease (C-107B)
• Additionally referred to as: Application for administrative approval of a surface commingle or off-lease measurement (C-107B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-107B |
Main Form |
True |
True |
|
Summary |
Summary of proposal |
True |
True |
|
Proposed Allocation |
Proposed Allocation and Supporting Data |
False |
False |
* Not required for OLM |
Lease Map |
Lease Map |
True |
True |
* Lease map with wells, laterals, and facilities depicted |
Facility Diagram |
Facility Diagram |
False |
False |
* Not required for OLM |
Commingling Statement |
Commingling will Not Reduce Value Statement |
False |
False |
* Statement that commingling will not reduce the total remaining production's value |
Notified Persons w/ Tracking |
List of Notified Persons and Tracking Numbers |
False |
False |
* Required if ownership is diverse as defined by 19.15.12.7(A) NMAC |
Identical Ownership Statement |
Identical Ownership Statement |
False |
False |
* Required if ownership is identical as defined by 19.15.12.7(B) NMAC |
Proof of BLM/SLO Notice |
Proof of BLM/SLO Notice |
False |
False |
* Required if Federal or State lands are involved |
C-102 |
C-102 |
False |
False |
* C-102s for each well |
Comm./Pool. Agreement |
Communitization/Pooling Agreement |
False |
False |
* Communitization or pooling agreements if applicable |
Administrative Checklist |
Administrative Application Checklist |
False |
False |
* Department Use Only Attachment |
Correspondence |
Correspondence |
False |
False |
* Department Use Only Attachment |
OCD Review |
OCD Review |
False |
False |
* Department Use Only Attachment |
Signed Order |
Signed Order |
False |
True |
* Department Use Only Attachment |
|
$150 fee required |
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (7) form C-107 - application for multiple completion;
(8) form C-107-A - application for downhole commingling;
(9) form C-107-B - application for surface commingling (diverse ownership);
19.15.7.18 APPLICATION FOR MULTIPLE COMPLETION (Form C-107): An operator shall file form C-107, when applicable, in accordance with Subsection A of 19.15.16.15 NMAC.
|
C-108 |
[C-108] Fluid Injection Well (C-108)
• Additionally referred to as: Application for a fluid injection well permit (C-108).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-108 |
Main Form |
True |
True |
|
C-102 |
C-102 |
True |
True |
|
Wellbore Diagram |
Wellbore Diagram |
True |
True |
|
Proof of Notice |
Proof of Notice |
True |
True |
|
AOR Analysis |
Area Of Review Analysis |
True |
True |
|
Tabulation of Wells |
Tabulation of wells in Area Of Review |
True |
True |
* Including diagrams for penetrating wells |
Fluid Analysis |
Injectate and Formation Fluid Analysis |
True |
True |
|
Seismicity Analysis |
Seismicity Analysis |
True |
True |
* For high volume Devonian wells , especially near faults |
Operational Details |
Operational Details |
True |
True |
|
Support Doc |
Supporting Documentation |
False |
False |
* For OCD use only |
|
$500 fee required |
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (10) form C-108 - application to dispose of salt water by injection into a porous formation;
19.15.7.19 APPLICATION FOR AUTHORIZATION TO INJECT (Form C-108): An operator shall file form C-108 in accordance with Subsection B of 19.15.26.8 NMAC.
|
C-109 |
[C-109] Discovery of New Pool (C-109)
• Additionally referred to as: Application for Discovery Allowable and Creation of a New Pool (C-109).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-109 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (11) form C-109 - application for discovery allowable and creation of a new pool;
19.15.7.20 APPLICATION FOR DISCOVERY ALLOWABLE AND CREATION OF A NEW POOL (Form C-109): An operator shall file form C-109, when applicable, in accordance with 19.15.20.16 NMAC.
|
C-111 |
[C-111] Gas Transporter Monthly (C-111)
• Additionally referred to as: Gas Transporter's and Facility Monthly Report (C-111).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-111 |
Main Form |
True |
True |
|
C-111A |
C-111A, Gas Receipts Continuation Sheet |
False |
False |
* Required if needed |
C-111B |
C-111B, Gas Disposition Continuation Sheet |
False |
False |
* Required if needed |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (12) form C-111 - gas transporter’s monthly report (sheet 1 and sheet 2);
19.15.7.21 GAS TRANSPORTER’S MONTHLY REPORT (Form C-111):
A. An operator shall complete and maintain for the division’s inspection, form C-111 monthly in accordance with Subsections B, C and D of 19.15.7.21 NMAC. The transporter shall itemize information on sheet no. 2 of form C-111 by pool, by operator and by lease, in alphabetical order.
B. An operator of a gas gathering system, gas transportation system, recycling system, fuel system, gas lift system, gas drilling operation, etc. shall complete and maintain for division inspection form C-111 each month. The form shall cover gas, casinghead gas and carbon dioxide gas taken into a system during the preceding month and shall show the gas’ source and its disposition.
C. An operator of a gasoline plant, cycling plant or other plant at which gasoline, butane, propane, kerosene, oil or other products are extracted from gas within the state shall complete and maintain for the division’s inspection form C-111 each month. The form shall cover gas, casinghead gas and carbon dioxide gas the plant has taken during the preceding month and shall show the gas’ source and its disposition. If an operator owns more than one plant in a given division district, the operator shall file sheet no. 1 of form C-111 for each plant. In preparing sheet no. 2, the operator shall consolidate requisitions for plants in the district, itemized in the order described in the Subsection A of 19.15.7.21 NMAC.
D. Where a producer takes gas and uses it for any of the above uses, the producer shall complete and maintain for division inspection form C-111 itemizing such gas. The producer shall also include this gas on form C-115. The producer shall also include gas used on the lease from which it was produced for consumption in lease houses, treaters, compressors, combustion engines and other similar equipment, or gas that is flared, on the form C-115 but shall not include it on form C-111.
|
C-112 |
[C-112] Oil Transporter Monthly (C-112)
• Additionally referred to as: Oil Transporter's or Storer's Monthly Report (C-112).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-112 |
Main Form |
True |
True |
|
C-112A |
C-112A, Receipts Continuation Sheet |
False |
False |
* Required if needed |
C-112B |
C-112B, Deliveries Continuation Sheet |
False |
False |
* Required if needed |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (13) form C-112 - transporter’s and storer’s monthly report;
(14) form C-112-A - receipts continuation sheet;
(15) form C-112-B - deliveries continuation sheet;
19.15.7.22 TRANSPORTER’S AND STORER’S MONTHLY REPORT (Form C-112): A transporter or storer of oil and liquid hydrocarbons within the state shall complete and maintain for division inspection for each calendar month a form C-112 containing complete information and data indicated by the form respecting stocks of oil and liquid hydrocarbons on hand and receipts and deliveries of oil and liquid hydrocarbons by pipeline and trucks within the state, and receipts and deliveries from leases to storers or refiners; between transporters within the state; between storers and refiners within the state.
|
C-115 |
[C-115] EP Production Monthly Report (C115)
• Additionally referred to as: Electronic Permit Production Monthly Report (C115).
|
|
[C-115B] Midstream Natural Gas Waste Report (MidstreamGasWaste)
• Additionally referred to as: Midstream Natural Gas Waste Report (MidstreamGasWaste).
|
|
[C-115B] Upstream Natural Gas Waste Report (UpstreamGasWaste)
• Additionally referred to as: Upstream Natural Gas Waste Report (UpstreamGasWaste).
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (17) form C-115 - operator’s monthly report;
(18) form C-115-EDP - operator’s monthly report (electronic data processing);
19.15.7.24 OPERATOR’S MONTHLY REPORT (Form C-115):
A. An operator shall file a form C-115 for each non-plugged well completion for which the division has approved a form C-104 and for each secondary or other enhanced recovery project or pressure maintenance project injection well or other injection well within the state, setting forth complete information and data indicated on the forms in the order, format and style the director prescribes. The operator shall estimate oil production from wells producing into common storage as accurately as possible on the basis of periodic tests.
B. An operator shall file the reports 19.15.7.24 NMAC requires using the division’s web-based online application on or before the 15th day of the second month following the month of production, or if such day falls on a weekend or holiday, the first workday following the 15th. An operator may apply to the division for exemption from the electronic filing requirement based upon a demonstration that such requirement would operate as an economic or other hardship.
C. If an operator fails to file a form C-115 that the division accepts, the division shall, within 30 days of the appropriate filing date, notify the operator by electronic mail or letter of its intent to cancel the operator’s authorization to transport or inject if the operator does not file an acceptable and complete form C-115. The notice shall inform the operator of the right to request a hearing pursuant to 19.15.4.8 NMAC. If the operator does not either file an acceptable and complete form C-115 or request a hearing on the proposed cancellation within 60 days of the original due date of the form C-115, the division may cancel the operator’s authority to transport from or inject into all wells it operates.
|
C-116 |
[C-116] Gas - Oil Ratio Test (C-116)
• Additionally referred to as: Gas - Oil Ratio Test (C-116).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-116 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (19) form C-116 - gas-oil ratio tests;
19.15.7.25 GAS-OIL RATIO TESTS (Form C-116): An operator shall make and report gas-oil ratio tests on form C-116 as prescribed in 19.15.18.8 NMAC and applicable special pool orders. The operator shall file the form C-116.
|
C-117 |
[C-117] Tank Cleaning/Disposal at Well (C-117A)
• Additionally referred to as: Tank Cleaning, Sediment Oil Removal, Transportation of Miscellaneous Hydrocarbons and Disposal Well Permit (C-117A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-117A |
Main Form |
True |
True |
|
|
|
[C-117] Tank Cleaning/Disposal at Facility (C-117AF)
• Additionally referred to as: Tank Cleaning, Sediment Oil Removal, Transportation of Miscellaneous Hydrocarbons and Disposal Facility Permit (C-117AF).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-117AF |
Main Form |
True |
True |
|
|
|
[C-117] Sediment Disposal Monthly (C-117B)
• Additionally referred to as: Monthly Sediment Oil Disposal Statement (C-117B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-117B |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (20) form C-117-A - tank cleaning, sediment oil removal, transportation of miscellaneous hydrocarbons and disposal permit;
(21) form C-117-B - monthly sediment oil disposal statement;
19.15.7.26 TANK CLEANING, SEDIMENT OIL REMOVAL, TRANSPORTATION OF MISCELLANEOUS HYDROCARBONS AND DISPOSAL PERMIT (Form C-117-A) AND MONTHLY SEDIMENT OIL DISPOSAL STATEMENT (Form C-117-B):
A. An operator shall file form C-117-A with the appropriate division district office in accordance with Subsections B, C and H of 19.15.18.17 NMAC.
B. An operator shall file form C-117-B with the division’s Santa Fe office and the appropriate division district office in accordance with Subsection D of 19.15.18.17 NMAC.
|
C-118 |
[C-118] Treatment Plant Monthly (C-118)
• Additionally referred to as: Treating Plant Operators; Monthly Report (C-118).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-118 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (22) form C-118 - treating plant operator’s monthly report (sheet 1 and sheet 2);
19.15.7.27 TREATING PLANT OPERATOR’S MONTHLY REPORT (Form C-118): A treating plant operator shall file on a monthly basis form C-118 with the appropriate division district office. The form C-118 shall contain all the information the form requires. Column 1 of sheet 1-A of form C-118 entitled permit number, references form C-117-A, for each lot of oil the operator picked up for processing.
|
C-120 |
[C-120] Water Disposal Monthly (C-120A)
• Additionally referred to as: Monthly Water Disposal Report (Part 36 Surface Waste Management) (C-120A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-120A |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (23) form C-120-A - monthly water disposal report;
19.15.7.28 MONTHLY WATER DISPOSAL REPORT (Form C-120-A): An operator of a salt water disposal system shall report its operations on form C-120-A. The operator shall file form C-120-A in duplicate, with one copy to the division’s Santa Fe office and one copy to the appropriate division district office, and shall postmark the form no later than the 15th day of the second succeeding month.
|
C-122 |
[C-122] Gas Back Pressure Test (C-122)
• Additionally referred to as: Multipoint and One Point Back Pressure Test for Gas Well (C-122).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-122 |
Main Form |
True |
True |
|
|
|
[C-122] Well Deliverability Test (C-122A)
• Additionally referred to as: Well Deliverability Test Report (C-122A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-122A |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (26) form C-122 - multi-point and one point back pressure test for gas wells;
(27) form C-122-A - gas well test data sheet-San Juan basin (initial deliverability test, blue paper; annual deliverability test, white);
(28) form C-122-B - initial potential test data sheet;
(29) form C-122-C - deliverability test report;
(30) form C-122-D - worksheet for calculation of static column wellhead pressure (Pw);
(31) form C-122-E - worksheet for stepwise calculation of (surface) (subsurface) pressure (Pc and Pw);
(32) form C-122-F - worksheet for calculation of wellhead pressures (Pc or Pw) from known bottom hole pressure (Pf or Ps);
(33) form C-122-G - worksheet for calculation of static column pressure at gas liquid interface;
19.15.7.30 MULTIPOINT AND ONE POINT BACK PRESSURE TEST FOR GAS WELL (Form C-122):
A. Gas well test data sheet - San Juan basin (form C-122-A)
B. Initial potential test data sheet (form C-122-B)
C. Deliverability test report (form C-122-C)
D. Worksheet for calculation of static column wellhead pressure (Pw) (form C- 122-D)
E. Worksheet for stepwise calculation of (surface) (subsurface) pressure (Pc & Pw) (Pf & Ps) (form C-122-E)
F. Worksheet for calculation of wellhead pressures (Pc or Pw) from known bottom hole pressure (Pf or Ps) (form C-122-F)
G. Worksheet for calculation of status column pressure at gas liquid interface (form C-122-G). The operator shall file the forms listed in Subsections A through F of 19.15.7.30 NMAC with the appropriate division district office in accordance with the provisions of the manual for back-pressure testing of natural gas wells or gas well testing manual for northwest New Mexico, 19.15.19.8 NMAC and applicable special pool orders and proration orders.
|
C-123 |
[C-123] Creation of New Pool (C-123)
• Additionally referred to as: Application for administrative approval of a request for creation of a new pool (C-123).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-123 |
Main Form |
True |
True |
|
|
$150 fee required |
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (34) form C-123 - request for the creation of a new pool;
19.15.7.31 REQUEST FOR THE CREATION OF A NEW POOL (Form C-123): The appropriate division district office shall provide the operator of a well that requires the creation of a pool written instructions regarding the filing of form C-123.
|
C-126 |
[C-126] Oil Transport Recovered (C-126)
• Additionally referred to as: Permit to Transport Recovered Load Oil (C-126).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-126 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (37) form C-126 - permit to transport recovered load oil;
19.15.7.34 PERMIT TO TRANSPORT RECOVERED LOAD OIL (Form C-126): An applicant to transport recovered load oil shall file form C-126 with the appropriate division district office in conformance with 19.15.20.15 NMAC.
|
C-127 |
[C-127] Oil Allowable Change (C-127)
• Additionally referred to as: Request for Allowable Change (Oil) (C-127).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-127 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (38) form C-127 - request for allowable change;
19.15.7.35 REQUEST FOR ALLOWABLE CHANGE (Form C-127): An oil producer shall file form C-127 with the appropriate division district office not later than the 10th day of the month preceding the month for which an oil producer is requesting oil well allowable changes.
|
C-129 |
[NOTIFY] Notification Of Major Venting and/or Flaring (NOMVF)
• Additionally referred to as: Notification of a Major Venting and/or Flaring Incident (NOMVF).
• Used to notify the OCD of venting and/or flaring events that equal to or exceed 500 MCF or otherwise qualifies as a major release as defined in 19.15.29.7 NMAC. • Successful submission of this notification generates an incident number for an operator to file a required C-129A or any other subsequent C-129 forms. • This notification does NOT replace the required C-129. Operators must submit an amended C-129 with all the required information within 15 days from the venting/flaring Event. • Successfully submitted notifications of major venting and/or flaring will email the OCD, satisfying the requirements from Paragraphs (1) of Subsection G of 19.15.27.7 NMAC and Paragraphs (1) of Subsection F of 19.15.28.8 NMAC.
|
|
[C-129] Venting and/or Flaring (C-129)
• Additionally referred to as: Venting and/or Flaring of Natural Gas Caused by an Emergency, a Malfunction or of Long Duration Report (C-129).
• Successful submission of this venting and/or flaring report generates an incident number for an operator to file any other subsequent C-129 forms. • This report will satisfy the notification requirement but ONLY if filed no later than 24 hours following the discovery or commencement of venting and/or flaring. • Any reported major venting and/or flaring will email the appropriate district office upon successful submission, satisfying the requirement from Paragraph (1) of Subsection G of 19.15.27.7 NMAC.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Compositional Analysis |
Compositional analysis of vented or flared natural gas |
True |
True |
|
Volume Calculation |
Calculations or Specific Justification for the Volumes |
True |
True |
* Determination used for Nature and Volume of Venting or Flaring |
Scaled Site Map |
Scaled Site Map |
False |
False |
* Scaled sitemap with GPS coordinates showing point of venting or flaring |
|
|
[C-129] Amend Venting and/or Flaring (C-129A)
• Additionally referred to as: Amending of Venting and/or Flaring Incident (C-129A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Compositional Analysis |
Compositional analysis of vented or flared natural gas |
False |
False |
|
Volume Calculation |
Calculations or Specific Justification for the Volumes |
False |
False |
* Determination used for Nature and Volume of Venting or Flaring |
|
|
[C-129] Cancel Venting and/or Flaring (C-129C)
• Additionally referred to as: Cancellation of Venting and/or Flaring Incident (C-129C).
|
|
[C-129] Exception to No-Flare Rule (C-129EX)
• Additionally referred to as: Application for Exception to No-Flare Rule (C-129EX).
• This form is retired with the implementation of the 19.15.27 NMAC (05/25/2021).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-129EX |
Main Form |
True |
True |
|
|
|
|
C-131 |
[C-131] Gas Storage Monthly (C-131A)
• Additionally referred to as: Monthly Gas Storage Report (C-131A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-131A |
Main Form |
True |
True |
|
|
|
[C-131] LPG Storage Annual (C-131B)
• Additionally referred to as: Annual LPG Storage Report (C-131B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-131B |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (41) form C-131-A - monthly gas storage report;
(42) form C-131-B - annual LPG storage report;
19.15.7.39 MONTHLY GAS STORAGE REPORT (Form C-131-A); ANNUAL LPG STORAGE REPORT (Form C-131-B):
A. An operator of an underground gas storage project shall report its operation monthly on form C-131-A. The operator shall file form C-131-A with the division’s Santa Fe office with a copy to the appropriate division district office and shall postmark it not later than the 24th day of the next succeeding month.
B. An operator of underground liquefied petroleum gas storage projects approved by the division shall report its operations annually on form C-131-B.
|
C-133 |
[C-133] Prod. Water Move Initial (C-133A)
• Additionally referred to as: Authorization to Move Produced Water (Initial Application) (C-133A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-133A |
Main Form |
True |
True |
|
NMDOT Warrant for Transportation |
NMDOT Warrant for Transportation |
False |
True |
|
|
$150 fee required |
[C-133] Prod. Water Move Correction (C-133B)
• Additionally referred to as: Authorization to Move Produced Water (Amended Address / Contact Information) (C-133B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-133B |
Main Form |
True |
True |
|
NMDOT Warrant for Transportation |
NMDOT Warrant for Transportation |
False |
True |
|
|
$150 fee required |
[C-133] Prod. Water Move Cancellation (C-133C)
• Additionally referred to as: Authorization to Move Produced Water (Cancellation Notification) (C-133C).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Cancel Transporting |
Cancellation/No Longer Transporting
|
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (43) form C-133 - authorization to move produced water exhibit “A”;
19.15.7.40 AUTHORIZATION TO MOVE PRODUCED WATER:
A. A transporter of produced water shall obtain the division’s approval of form C-133 in accordance with 19.15.34 NMAC prior to transportation.
B. Approval of a single form C-133 is valid for leases the transporter serves.
|
C-135 |
[C-135] Gas (Re/Dis)Connections (C-135)
• Additionally referred to as: Gas Well Connection, Reconnection, or Disconnection Notice (C-135).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-135 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (45) form C-135 - gas well connection, reconnection or disconnection notice;
19.15.7.41 GAS WELL CONNECTION, RECONNECTION OR DISCONNECTION NOTICE: A gas transporter accepting gas for delivery from a wellhead or central point of delivery shall notify the division within 30 days of a new connection or reconnection to or disconnection from the gathering or transportation system by filing form C-135 with the appropriate division district office.
|
C-136 |
[C-136] Gas Alt Measure Method (C-136)
• Additionally referred to as: Application for Approval to Use an Alternate Gas Measurement Method (C-136).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-136 |
Main Form |
True |
True |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (46) form C-136 - application for approval to use an alternate gas measurement method;
19.15.7.42 APPLICATION FOR APPROVAL TO USE AN ALTERNATE GAS MEASUREMENT METHOD (Form C-136):
A. An operator shall use form C-136 to request and obtain division approval for use of an alternate procedure for measuring gas production from a well that is not capable of producing more than 15 MCFD (Paragraph (1) of Subsection B of 19.15.19.9 NMAC) or for a well that has a producing capacity of 100 MCFD or less and is on a multi-well lease (Paragraph (2) of Subsection B of 19.15.19.9 NMAC).
B. An operator shall fill out the applicable information required on form C-136 with the required supplemental information attached, and file it with the appropriate division district office.
|
C-137 |
[C-137] SWM Facility (C-137)
• Additionally referred to as: Application for administrative approval of a surface waste management facility (C-137).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-137 |
Main Form |
True |
True |
|
Contact Info |
Contact Info of Applicant/Principle Officers/Owners of 25% or more |
False |
False |
|
Survey Plat/Topo Maps |
Survey Plat/Topo Maps |
False |
False |
|
Surface Ownership |
Surface Ownership within 1 mile of facility boundary |
False |
False |
|
Construction Diagrams |
Construction Plan and Diagrams |
False |
False |
|
Engineering Designs |
Engineering Designs, certified by a registered professional engineer |
False |
False |
|
Waste Management Plan |
Waste Management Plan |
False |
False |
|
Inspection Plan |
Inspection and Maintenance Plan |
False |
False |
|
H2S Plan |
H2S Prevention and Contingency Plan |
False |
False |
|
Closure Plan |
Closure and Post Closure Plan |
False |
False |
|
Closure Cost Estimate |
Closure and Post Closure Cost Estimate |
False |
False |
|
Contingency Plan |
Contingency Plan |
False |
False |
|
Run-On/Off Plan |
Run-On/Off Water Control Plan |
False |
False |
|
Vadose Plan |
Vadose/Water Monitor Plan |
False |
False |
|
Leachate Plan |
Landfill Leachate Plan |
False |
False |
|
Gas Plan |
Landfill Gas Safety Plan |
False |
False |
|
BMP Plan |
Best Management Practice (BMP) Plan |
False |
False |
|
Hydro Geologic Report |
Hydro Geologic Report |
False |
False |
|
Geotechnical Report |
Geotechnical Report |
False |
False |
|
Siting Criteria |
Siting Criteria Demonstration |
False |
False |
|
OCD Response |
OCD Response |
False |
False |
* Department Use Only Attachment |
|
$10000 fee required |
[C-137] SWMF Minor Modification (C-137A)
• Additionally referred to as: Minor Modification of a Surface Waste Management Facility (C-137A).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-137A |
Main Form |
True |
True |
|
Contact Info |
Contact Info of Applicant/Principle Officers/Owners of 25% or more |
False |
False |
|
Survey Plat/Topo Maps |
Survey Plat/Topo Maps |
False |
False |
|
Surface Ownership |
Surface Ownership within 1 mile of facility boundary |
False |
False |
|
Construction Diagrams |
Construction Plan and Diagrams |
False |
False |
|
Engineering Designs |
Engineering Designs, certified by a registered professional engineer |
False |
False |
|
Waste Management Plan |
Waste Management Plan |
False |
False |
|
Inspection Plan |
Inspection and Maintenance Plan |
False |
False |
|
H2S Plan |
H2S Prevention and Contingency Plan |
False |
False |
|
Closure Plan |
Closure and Post Closure Plan |
False |
False |
|
Closure Cost Estimate |
Closure and Post Closure Cost Estimate |
False |
False |
|
Contingency Plan |
Contingency Plan |
False |
False |
|
Run-On/Off Plan |
Run-On/Off Water Control Plan |
False |
False |
|
Vadose Plan |
Vadose/Water Monitor Plan |
False |
False |
|
Leachate Plan |
Landfill Leachate Plan |
False |
False |
|
Gas Plan |
Landfill Gas Safety Plan |
False |
False |
|
BMP Plan |
Best Management Practice (BMP) Plan |
False |
False |
|
Hydro Geologic Report |
Hydro Geologic Report |
False |
False |
|
Geotechnical Report |
Geotechnical Report |
False |
False |
|
Siting Criteria |
Siting Criteria Demonstration |
False |
False |
|
OCD Response |
OCD Response |
False |
False |
* Department Use Only Attachment |
|
$150 fee required |
[C-137] SWMF Major Modification (C-137B)
• Additionally referred to as: Major Modification of a Surface Waste Management Facility (C-137B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-137B |
Main Form |
True |
True |
|
Contact Info |
Contact Info of Applicant/Principle Officers/Owners of 25% or more |
False |
False |
|
Survey Plat/Topo Maps |
Survey Plat/Topo Maps |
False |
False |
|
Surface Ownership |
Surface Ownership within 1 mile of facility boundary |
False |
False |
|
Construction Diagrams |
Construction Plan and Diagrams |
False |
False |
|
Engineering Designs |
Engineering Designs, certified by a registered professional engineer |
False |
False |
|
Waste Management Plan |
Waste Management Plan |
False |
False |
|
Inspection Plan |
Inspection and Maintenance Plan |
False |
False |
|
H2S Plan |
H2S Prevention and Contingency Plan |
False |
False |
|
Closure Plan |
Closure and Post Closure Plan |
False |
False |
|
Closure Cost Estimate |
Closure and Post Closure Cost Estimate |
False |
False |
|
Contingency Plan |
Contingency Plan |
False |
False |
|
Run-On/Off Plan |
Run-On/Off Water Control Plan |
False |
False |
|
Vadose Plan |
Vadose/Water Monitor Plan |
False |
False |
|
Leachate Plan |
Landfill Leachate Plan |
False |
False |
|
Gas Plan |
Landfill Gas Safety Plan |
False |
False |
|
BMP Plan |
Best Management Practice (BMP) Plan |
False |
False |
|
Hydro Geologic Report |
Hydro Geologic Report |
False |
False |
|
Geotechnical Report |
Geotechnical Report |
False |
False |
|
Siting Criteria |
Siting Criteria Demonstration |
False |
False |
|
OCD Response |
OCD Response |
False |
False |
* Department Use Only Attachment |
|
$150 fee required |
[C-137] Small Landfarm (C-137EZA)
• Additionally referred to as: Registration for Small Landfarm (C-137EZA).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-137EZ |
Main Form |
True |
True |
|
Surface Owner Agreement |
Surface Owner Agreement |
False |
False |
* Required if not surface ownwer |
Siting Criteria |
Siting Criteria |
False |
False |
|
Survey Plat/Topo Maps |
Survey Plat/Topo Maps |
False |
False |
|
Lab Results |
Closure Laboratory Analytical Results |
False |
False |
|
Photographs |
Closure Photographs |
False |
False |
|
OCD Response |
OCD Response |
False |
False |
* Department Use Only Attachment |
|
|
[C-137] Small Landfarm Final Closure (C-137EZB)
• Additionally referred to as: Final Closure Report for Small Landfarm (C-137EZB).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-137EZB |
Main Form |
True |
True |
|
Surface Owner Agreement |
Surface Owner Agreement |
False |
False |
* Required if not surface ownwer |
Siting Criteria |
Siting Criteria |
False |
False |
|
Survey Plat/Topo Maps |
Survey Plat/Topo Maps |
False |
False |
|
Lab Results |
Closure Laboratory Analytical Results |
False |
False |
|
Photographs |
Closure Photographs |
False |
False |
|
OCD Response |
OCD Response |
False |
False |
* Department Use Only Attachment |
|
|
[C-137] Non-Fee SWMF Submittal (SWMF NON-FEE SUBMITTAL)
• Additionally referred to as: Surface Waste Management Facility Non-Fee Submittal (SWMF NON-FEE SUBMITTAL).
• This is for required Reports for Part 36 facilities, or Facility Background Sampling Plans, Closure/Post Closure Plans for Part 711 Etc. • This is NOT for Modifications, Renewals, or New applications.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
SWMF NON-FEE SUBMITTAL |
Main Form |
True |
True |
|
OCD Response |
OCD Response |
False |
False |
* Department Use Only Attachment |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (47) form C-137 - application for waste management facility;
(48) form C-137-EZ - registration/final closure report for small landfarm;
19.15.36.7 B. (9) “Major modification” means a modification of a surface waste management facility that involves an increase in the land area that the permitted surface waste management facility occupies; a change in the design capacity or nature of the permitted oil field waste stream; addition of a new treatment process; an exception to, waiver of or change to a numerical standard provided in 19.15.36 NMAC; or other modification that the division determines is sufficiently substantial that public notice and public participation in the application process are appropriate.
(10) “Minor modification” means a modification of a surface waste management facility that is not a major modification.
19.15.36.8 SURFACE WASTE MANAGEMENT FACILITY PERMITS AND APPLICATION REQUIREMENTS:
C. Application requirements for new facilities, major modifications and permit renewals. An applicant or operator shall file an application, form C-137, for a permit for a new surface waste management facility, to modify an existing surface waste management facility or for permit renewal with the environmental bureau in the division’s Santa Fe office. The application shall include:
(1) the names and addresses of the applicant and principal officers and owners of twenty-five percent or more of the applicant;
(2) a plat and topographic map showing the surface waste management facility’s location in relation to governmental surveys (quarter-quarter section, township and range); highways or roads giving access to the surface waste management facility site; watercourses; fresh water sources, including wells and springs; and inhabited buildings within one-half mile of the site’s perimeter based upon the records of the applicable county clerk or clerk’s office;
(3) the names and addresses of the surface owners of the real property on which the surface waste management facility is sited and surface owners of the real property within one mile of the site’s perimeter;
(4) a description of the surface waste management facility with a diagram indicating the location of fences and cattle guards, and detailed construction/installation diagrams of pits, liners, dikes, piping, sprayers, tanks, roads, fences, gates, berms, pipelines crossing the surface waste management facility, buildings and chemical storage areas;
(5) engineering designs, certified by a registered professional engineer, including technical data on the design elements of each applicable treatment, remediation and disposal method and detailed designs of surface impoundments;
(6) a plan for management of approved oil field wastes that complies with the applicable requirements contained in 19.15.36.13 NMAC, 19.15.36.14 NMAC, 19.15.36.15 NMAC and 19.15.36.17 NMAC;
(7) an inspection and maintenance plan that complies with the requirements contained in Subsection L of 19.15.36.13 NMAC;
(8) a hydrogen sulfide prevention and contingency plan that complies with those provisions of 19.15.11 NMAC that apply to surface waste management facilities;
(9) a closure and post closure plan, including a responsible third party contractor’s cost estimate, sufficient to close the surface waste management facility in a manner that will protect fresh water, public health and the environment, and to comply with the closure and post closure requirements contained in Subsections A through F of 19.15.36.18 NMAC;
(10) a contingency plan that complies with the requirements of Subsection N of 19.15.36.13 NMAC and with NMSA 1978, Sections 12-12-1 through 12-12-30, as amended;
(11) a plan to control run-on water onto the site and run-off water from the site that complies with the requirements of Subsection M of 19.15.36.13 NMAC;
(12) in the case of an application to permit a new or expanded landfill, a leachate management plan that describes the anticipated amount of leachate that will be generated and the leachate’s handling, storage, treatment and disposal, including final post closure options;
(13) in the case of an application to permit a new or expanded landfill, a gas safety management plan that complies with the requirements of Subsection O of 19.15.36.13 NMAC;
(14) a best management practice plan to ensure protection of fresh water, public health and the environment;
(15) geological/hydrological data including:
(a) a map showing names and location of streams, springs or other watercourses, and water wells within one mile of the site;
(b) laboratory analyses, performed by an independent commercial laboratory, for major cations and anions; BTEX; RCRA metals; and TDS of ground water samples of the shallowest fresh water aquifer beneath the proposed site;
(c) depth to, formation name, type and thickness of the shallowest fresh water aquifer;
(d) soil types beneath the proposed surface waste management facility, including a lithologic description of soil and rock members from ground surface down to the top of the shallowest fresh water aquifer;
(e) geologic cross-sections;
(f) potentiometric maps for the shallowest fresh water aquifer; and
(g) porosity, permeability, conductivity, compaction ratios and swelling characteristics for the sediments on which the contaminated soils will be placed;
(16) certification by the applicant that information submitted in the application is true, accurate and complete to the best of the applicant’s knowledge, after reasonable inquiry; and
(17) other information that the division may require to demonstrate that the surface waste management facility’s operation will not adversely impact fresh water, public health or the environment and that the surface waste management facility will comply with division rules and orders.
D. Application requirements for minor modifications. Before making a minor modification, the operator of an existing surface waste management facility shall file a form C-137A with the environmental bureau in the division’s Santa Fe office describing the proposed change. Minor modifications are not subject to Subsection C of 19.15.36.8 NMAC. If the division denies the application for a minor modification, the operator may request a hearing pursuant to Subsection B of 19.15.36.10 NMAC.
|
C-138 |
[C-138] Solid Waste Accept (C-138)
• Additionally referred to as: Request for Approval to Accept Solid Waste (C-138).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-138 |
Main Form |
True |
True |
|
Lab Results |
Laboratory Analytical Results |
False |
False |
|
MSD Information |
MSD Information |
False |
False |
|
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (49) form C-138 - request for approval to accept solid waste;
|
C-139 |
[C-139] EP Production Restoration (C139)
• Additionally referred to as: Electronic Permit Production Restoration (C139).
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (50) form C-139 - application for qualification of production restoration project and certification of approval;
19.15.7.43 APPLICATION FOR PRODUCTION RESTORATION PROJECT (C-139):
A. An operator shall use the division’s web-based online application to apply for the production restoration tax incentive.
B. An operator shall enter a user identification number and password that it has obtained from the division and select the well for which the operator is requesting the production restoration tax incentive. The operator shall then enter the date it began the production restoration, the date the well returned to production and the process the operator used to return the well to production. The operator shall certify that the information is complete and correct.
|
C-140 |
[C-140] EP Well Workover (C140)
• Additionally referred to as: Electronic Permit Well Workover (C140).
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (51) form C-140 - application for qualification of well workover project and certification of approval;
19.15.7.44 APPLICATION FOR WELL WORKOVER PROJECT (C-140):
A. An operator shall use the division’s web-based online application to apply for the well workover tax incentive.
B, An operator shall enter a user identification number and password that it has obtained from the division and select the well for which the operator is requesting the well workover tax incentive. The operator shall enter the date that it commenced the well workover and the date it completed the well workover. The operator shall attach a description of the workover procedure it performed to increase production and a production curve or data tabulation showing at least 12 months of production prior to the well workover and at least three months of production following the well workover to reflect a positive production increase.
|
C-141 |
[NOTIFY] Notification Of Release (NOR)
• Additionally referred to as: Notification of a release (NOR).
• Successful submission of this notification generates an incident number for an operator to file subsequent C-141. • This notification does NOT replace the required initial C-141. • All notifications reported as a major release will email the appropriate district office upon successful submission, satisfying the requirement from Paragraph (1) of Subsection A of 19.15.29.10 NMAC. • Requirement: per Paragraph (1) of Subsection A of 19.15.29.10 NMAC, in reporting a major release the responsible party must submit a NOR within 24 hours of discovery of the release. • Requirement: per Subsection B of 19.15.29.10 NMAC, in reporting a minor release the responsible party must submit a NOR within 15 days of discovery of the release.
|
|
[NOTIFY] Notification of Legacy Release (NOR-LR)
• Additionally referred to as: Notification of a release (NOR-LR).
• This form is not submitted independently; it is a designation assigned to a NOR submission. ο A NOR submission that has a Date of Discovery prior to 08/15/2018 (rule change). ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[C-141] Release Corrective Action (C-141)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141).
• Used to submit Initial Response, Site Characterizations and Remediation Plan, Deferral Request, Remediation Closure Request, Reclamation Report, and Re-vegetation Report. • Used to report the site assessments and remediation activities for all releases, regardless of volume or containment within a lined containment area. • The following submission requirement summary applies conditionally per Sections 10 through 13 of 19.15.29 NMAC. ο Explicitly excluded from this summary are exceptions to the submission due date requirements when modified by OCD approved extensions, deferrals or variances. ο Submission due date requirements are not exclusive and all or most can be satified when remediation activity is completed and reported upon within 90 days of the date of discovery. ο Submitters are encouraged to reach out to the OCD for clarification on due date requirement uncertainty as soon as necessary. • Requirement: the responsible party must file (at least) an initial C-141 within 15 days of discovery of the release, regardless of volume. • Requirement: regardless of volume, the responsible party must file form C-141 within 90 days of discovery of the release providing a complete site characterization / remediation plan. • Requirement: for all releases containing liquids, regardless of volume, the responsible party must file form C-141 within 90 days of the remediation plan approval including a request for remediation closure approval. ο A request for remediation closure should not be submitted until all remedial activities are complete. ο The responsible party must plan and account for the two business day Notification Of Liner Inspection (C-141L) / Sampling (C-141N) requirement. • Requirement: impacted areas no longer in use, regardless of volume, the responsible party must file form C-141 after the completion of reclamation activities including a request for reclamation report approval. ο The responsible party shall reclaim all impacted surface areas, as early and as nearly as practical to their original condition (prior to the release) or their final land use. ο All reclaimed impacted surface areas must be stabilized and maintained in such a way as to minimize dust and erosion to the extent practical. • Requirement: impacted areas no longer in use, regardless of volume, the responsible party must file form C-141 after the completion of re-vegetation activities including a request for re-vegetation report approval. ο All reclaimed impacted surface areas no longer in use must be reseeded in the first favorable growing season following remediation closure approval. ο Restoration is not complete until uniform vegetation criteria has been met and failure means the responsible party needs to do ???
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Volume Calculation |
Initial Response - Calculations or Specific Justification for the Volumes |
False |
False |
* Determination used for Nature and Volume of Release |
Water Sources |
Site Characterization - Water Sources/Course Determination |
False |
False |
* Determination of water sources and significant watercourses within ½-mile of the lateral extents of the release |
Scaled Site Map |
Site Characterization - Scaled Site Map |
False |
False |
* Scaled site map showing impacted area, surface features, subsurface features, delineation points, and monitoring wells |
Field Data |
Site Characterization - Field Data |
False |
False |
* Field Data |
Soil Contaminant |
Site Characterization - Soil Contaminant Concentration |
False |
False |
* Data table of soil contaminant concentration data |
Water Depth |
Site Characterization - Water Depth Determination |
False |
False |
* Depth to water determination |
Boring Logs |
Site Characterization - Boring Logs |
False |
False |
* Boring or excavation logs |
Photographs |
Site Characterization - Photographs |
False |
False |
* Photographs including date and GIS information |
Topo Aerial Maps |
Site Characterization - Topographic/Aerial Maps |
False |
False |
* Topographic/Aerial maps |
Lab Data |
Site Characterization - Laboratory Data |
False |
False |
* Laboratory data including chain of custody |
Proposed Technique |
Remediation Plan - Proposed Technique |
False |
False |
* Detailed description of proposed remediation technique |
Scaled Site Map |
Remediation Plan - Scaled Site Map |
False |
False |
* Scaled sitemap with GPS coordinates showing delineation points |
Estimated Volume |
Remediation Plan - Estimated Volume |
False |
False |
* Estimated volume of material to be remediated |
Closure Criteria |
Remediation Plan - Closure Criteria |
False |
False |
* Closure criteria is to Table 1 specifications subject to 19.15.29.12(C)(4) NMAC |
Proposed Schedule |
Remediation Plan - Proposed Schedule |
False |
False |
* Proposed schedule for remediation (note if remediation plan timeline is more than 90 days OCD approval is required) |
Scaled Site Map |
Remediation Closure Request - Scaled Site Map |
False |
False |
* A scaled site and sampling diagram as described in 19.15.29.11 NMAC |
Photographs |
Remediation Closure Request - Photographs |
False |
False |
* Photographs of the remediated site prior to backfill or photos of the liner integrity if applicable (Note: appropriate OCD District office
must be notified 2 days prior to liner inspection) |
Lab Samples OR Liner Integrity |
Remediation Closure Request - Lab Samples OR Liner Integrity Report |
False |
False |
* Laboratory analyses of final sampling or liner integrity certification (Note: appropriate ODC District office must be notified 2 days prior to final sampling) |
Remediation Activities |
Remediation Closure Request - Remediation Activities |
False |
False |
* Description of remediation activities |
Scaled Site Map |
Reclamation Report - Scaled Site Map |
False |
False |
* Scaled site map showing reclaimed production area, reclaimed non-production area, errosion control features, and any site ponding. |
Photographs |
Reclamation Report - Photographs |
False |
False |
* Photographs of the reclamation site after backfill and recontouring has been completed |
Reseeding Plan |
Reclamation Report - Proposed Reseeding Plan |
False |
False |
* Proposed plan to revegetate site, specifically indicating reseeding mixture, identify next growing season and intended start date |
Reclamation Activities |
Reclamation Report - Reclamation Activities |
False |
False |
* Description of remediation activities |
Scaled Site Map |
Revegetation Report - Scaled Site Map |
False |
False |
* Scaled site map showing revegetated area, sample control area(s), points of evaluation for life form ratio and plant coverage. |
Photographs |
Revegetation Report - Photographs |
False |
False |
* Photographs of the site after revegetation efforts have been evaluated |
Revegetation Activities |
Revegetation Report - Revegetation Activities |
False |
False |
* Description of revegetation activities including a statement of completion OR an updated proposed reseeding plan |
|
$150 fee required |
[C-141] Initial C-141 (C-141-v-Initial)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141-v-Initial).
• This form is not submitted independently; it is a designation assigned to a C-141 submission. ο A C-141 submission (after go live date) that does not have a request to review a Remediation Plan. ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[C-141] Site Char./Remediation Plan C-141 (C-141-v-Plan)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141-v-Plan).
• This form is not submitted independently; it is a designation assigned to a C-141 submission. ο A C-141 submission (after go live date) that has a request to review a Site Characterization and Remediation Plan. ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[C-141] Deferral Request C-141 (C-141-v-Deferral)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141-v-Deferral).
• This form is not submitted independently; it is a designation assigned to a C-141 submission. ο A C-141 submission (after go live date) that has a request to review a Remediation Plan with a Deferral Request. ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[C-141] Remediation Closure Request C-141 (C-141-v-Closure)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141-v-Closure).
• This form is not submitted independently; it is a designation assigned to a C-141 submission. ο A C-141 submission (after go live date) that has a request to review a Remediation Closure Request. ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[C-141] Reclamation Report C-141 (C-141-v-Reclamation)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141-v-Reclamation).
• This form is not submitted independently; it is a designation assigned to a C-141 submission. ο A C-141 submission (after go live date) that has a request to review a Reclamation Report. ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[C-141] Revegetation Report C-141 (C-141-v-Revegetation)
• Additionally referred to as: Application for administrative approval of a release notification and corrective action (C-141-v-Revegetation).
• This form is not submitted independently; it is a designation assigned to a C-141 submission. ο A C-141 submission (after go live date) that has a request to review a Re-vegetation Report. ο Technically this is a system artifact to assist classification in Action Status searches and various reporting tasks.
|
|
[NOTIFY] Notification Of Liner Inspection (C-141L)
• Additionally referred to as: Notification for Liner Inspection for a Release (C-141L).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
|
|
[NOTIFY] Notification Of Sampling (C-141N)
• Additionally referred to as: Notification for (Final) Sampling of a Release (C-141N).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
|
|
[REPORT] Alternative Remediation Report (C-141AR)
• Additionally referred to as: Corrective Action Alternative Remediation Report (C-141AR).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
Remediation Activities |
Remediation Activities |
True |
False |
* Description of remediation activities |
|
|
[C-141] Cancellation Request (C-141C)
• Additionally referred to as: Request to Cancel the Notification of a Release (C-141C).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (52) form C-141 - release notification and corrective action;
|
C-144 |
[C-144] Below Grade Tank Plan (C-144B)
• Additionally referred to as: Pit, Below-Grade Tank, or Proposed Alternative Method Permit or Closure Plan Application (Below Grade Tanks) (C-144B).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144B |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Siting Criteria |
Siting Criteria |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
C-102 |
C-102 |
False |
False |
* Plat Survey (Pad Diagram) |
Depth to Water |
Depth to Water |
False |
False |
|
Site Specific Hydro Geologic |
Site Specific Hydro Geologic |
False |
False |
|
Design and Construction Plan |
Design and Construction Plan |
False |
False |
|
Design Drawing |
Design Drawing |
False |
False |
|
Operation and Maintenance Plan |
Operation and Maintenance Plan |
False |
False |
|
Closure Plan |
Closure Plan |
False |
False |
|
Closure Report |
Closure Report |
False |
False |
|
C-105 Rig release Date (Closure) |
C-105 Rig release Date (Closure) |
False |
False |
|
C-141 |
C-141 |
False |
False |
* Indicating Results |
Laboratory Analysis Results |
Laboratory Analysis Results |
False |
False |
|
Photographs |
Photographs |
False |
False |
|
Construction Notifications |
Construction Notifications |
False |
False |
|
Closure Sampling Notifications |
Closure Sampling Notifications |
False |
False |
|
Reclamation Notification |
Reclamation Notification |
False |
False |
|
List of Permitted Wells |
A list of wells with approved permits to drill multiwell pits |
False |
False |
|
Operator inspections |
Operator inspections |
False |
False |
|
Deed Notice |
Copy of Deed Notice with county clerk |
False |
False |
* If on private land |
H2S Plan |
H2S Plan |
False |
False |
|
|
$150 fee required |
[C-144] Emergency Pit Plan (C-144E)
• Additionally referred to as: Pit, Below-Grade Tank, or Proposed Alternative Method Permit or Closure Plan Application (Emergency Pits) (C-144E).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144E |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Siting Criteria |
Siting Criteria |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
C-102 |
C-102 |
False |
False |
* Plat Survey (Pad Diagram) |
Depth to Water |
Depth to Water |
False |
False |
|
Site Specific Hydro Geologic |
Site Specific Hydro Geologic |
False |
False |
|
Design and Construction Plan |
Design and Construction Plan |
False |
False |
|
Design Drawing |
Design Drawing |
False |
False |
|
Operation and Maintenance Plan |
Operation and Maintenance Plan |
False |
False |
|
Closure Plan |
Closure Plan |
False |
False |
|
Closure Report |
Closure Report |
False |
False |
|
C-105 |
C-105 |
False |
False |
* Rig release Date (Closure) |
C-141 |
C-141 |
False |
False |
* Indicating Results |
Laboratory Analysis Results |
Laboratory Analysis Results |
False |
False |
|
Photographs |
Photographs |
False |
False |
|
Construction Notifications |
Construction Notifications |
False |
False |
|
Closure Sampling Notifications |
Closure Sampling Notifications |
False |
False |
|
Reclamation Notification |
Reclamation Notification |
False |
False |
|
List of Permitted Wells |
A list of wells with approved permits to drill multiwell pits |
False |
False |
|
Operator inspections |
Operator inspections |
False |
False |
|
Deed Notice |
Copy of Deed Notice with county clerk |
False |
False |
* If on private land |
H2S Plan |
H2S Plan |
False |
False |
|
|
$150 fee required |
[C-144] Multiwell Management Pit Plan (C-144M)
• Additionally referred to as: Pit, Below-Grade Tank, or Proposed Alternative Method Permit or Closure Plan Application (Multiwell Management Pits) (C-144M).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144M |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Siting Criteria |
Siting Criteria |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
C-102 |
C-102 |
False |
False |
* Plat Survey (Pad Diagram) |
Depth to Water |
Depth to Water |
False |
False |
|
Site Specific Hydro Geologic |
Site Specific Hydro Geologic |
False |
False |
|
Design and Construction Plan |
Design and Construction Plan |
False |
False |
|
Design Drawing |
Design Drawing |
False |
False |
|
Operation and Maintenance Plan |
Operation and Maintenance Plan |
False |
False |
|
Closure Plan |
Closure Plan |
False |
False |
|
Closure Report |
Closure Report |
False |
False |
|
C-105 |
C-105 |
False |
False |
* Rig release Date (Closure) |
C-141 |
C-141 |
False |
False |
* Indicating Results |
Laboratory Analysis Results |
Laboratory Analysis Results |
False |
False |
|
Photographs |
Photographs |
False |
False |
|
Construction Notifications |
Construction Notifications |
False |
False |
|
Closure Sampling Notifications |
Closure Sampling Notifications |
False |
False |
|
Reclamation Notification |
Reclamation Notification |
False |
False |
|
List of Permitted Wells |
A list of wells with approved permits to drill multiwell pits |
False |
False |
|
Operator inspections |
Operator inspections |
False |
False |
|
Deed Notice |
Copy of Deed Notice with county clerk |
False |
False |
* If on private land |
H2S Plan |
H2S Plan |
False |
False |
|
|
$150 fee required |
[C-144] Permanent Pit Plan (C-144P)
• Additionally referred to as: Pit, Below-Grade Tank, or Proposed Alternative Method Permit or Closure Plan Application (Permanent Pits) (C-144P).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144P |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Siting Criteria |
Siting Criteria |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
C-102 |
C-102 |
False |
False |
* Plat Survey (Pad Diagram) |
Depth to Water |
Depth to Water |
False |
False |
|
Site Specific Hydro Geologic |
Site Specific Hydro Geologic |
False |
False |
|
Design and Construction Plan |
Design and Construction Plan |
False |
False |
|
Design Drawing |
Design Drawing |
False |
False |
|
Operation and Maintenance Plan |
Operation and Maintenance Plan |
False |
False |
|
Closure Plan |
Closure Plan |
False |
False |
|
Closure Report |
Closure Report |
False |
False |
|
C-105 |
C-105 |
False |
False |
* Rig release Date (Closure) |
C-141 |
C-141 |
False |
False |
* Indicating Results |
Laboratory Analysis Results |
Laboratory Analysis Results |
False |
False |
|
Photographs |
Photographs |
False |
False |
|
Construction Notifications |
Construction Notifications |
False |
False |
|
Closure Sampling Notifications |
Closure Sampling Notifications |
False |
False |
|
Reclamation Notification |
Reclamation Notification |
False |
False |
|
List of Permitted Wells |
A list of wells with approved permits to drill multiwell pits |
False |
False |
|
Operator inspections |
Operator inspections |
False |
False |
|
Deed Notice |
Copy of Deed Notice with county clerk |
False |
False |
* If on private land |
H2S Plan |
H2S Plan |
False |
False |
|
|
$150 fee required |
[C-144] Temporary Pit Plan (C-144T)
• Additionally referred to as: Pit, Below-Grade Tank, or Proposed Alternative Method Permit or Closure Plan Application (Temporary Pits) (C-144T).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144T |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Siting Criteria |
Siting Criteria |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
C-102 |
C-102 |
False |
False |
* Plat Survey (Pad Diagram) |
Depth to Water |
Depth to Water |
False |
False |
|
Site Specific Hydro Geologic |
Site Specific Hydro Geologic |
False |
False |
|
Design and Construction Plan |
Design and Construction Plan |
False |
False |
|
Design Drawing |
Design Drawing |
False |
False |
|
Operation and Maintenance Plan |
Operation and Maintenance Plan |
False |
False |
|
Closure Plan |
Closure Plan |
False |
False |
|
Closure Report |
Closure Report |
False |
False |
|
C-105 |
C-105 |
False |
False |
* Rig release Date (Closure) |
C-141 |
C-141 |
False |
False |
* Indicating Results |
Laboratory Analysis Results |
Laboratory Analysis Results |
False |
False |
|
Photographs |
Photographs |
False |
False |
|
Construction Notifications |
Construction Notifications |
False |
False |
|
Closure Sampling Notifications |
Closure Sampling Notifications |
False |
False |
|
Reclamation Notification |
Reclamation Notification |
False |
False |
|
List of Permitted Wells |
A list of wells with approved permits to drill multiwell pits |
False |
False |
|
Operator inspections |
Operator inspections |
False |
False |
|
Deed Notice |
Copy of Deed Notice with county clerk |
False |
False |
* If on private land |
H2S Plan |
H2S Plan |
False |
False |
|
|
$150 fee required |
[C-144] Legacy Below Grade Tank Plan (C-144LB)
• Additionally referred to as: Pit, Legacy BGT Requested Prior Documentation (Legacy Below Grade Tanks) (C-144LB).
• This is for resubmission of prior documentation requested by the OCD to gather in historic detail records. • This is NOT for requesting current approvals of pits, below-grade tanks or proposed alternative methods or closure plans.
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144LB |
Main Form |
True |
True |
|
|
|
[C-144] Pit Inventory (PIT INVENTORY)
• Additionally referred to as: Pit Inventory Form (PIT INVENTORY).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
PIT INVENTORY |
Main Form |
True |
True |
|
|
|
[C-144] PIT Generic Plan (C-144)
• Additionally referred to as: Application for administrative approval of a proposed alternative method permit or closure plan application (C-144).
• This form is no longer being accepted by the OCD. Use the appropriate variant from above after (03/07/2022).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-144 |
Main Form |
True |
True |
|
|
$150 fee required |
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (53) form C-144 - pit, closed-loop system, below-grade tank or proposed alternative method permit or closure plan application;
|
C-145 |
[C-145] EP Change of Operator (ChangeOp)
• Additionally referred to as: Electronic Permit Change of Operator (ChangeOp).
|
$150 fee required |
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (54) form C-145 - change of operator; and
|
C-146 |
[C-146] EP Name Change (NameChange)
• Additionally referred to as: Electronic Permit Name Change (NameChange).
|
|
Click to view related NMAC
Click again to collapse NMAC
19.15.7.8 D. (55) form C-146 - change of operator name.
|
C-147 |
[C-147] Water Recycle Long (C-147L)
• Additionally referred to as: Permit or Registration for Recycling and Re-use of Produced Water, Drilling Fluids and Liquid Oil Field Waste (Including Recycling Containment) (C-147L).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-147L |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
Siting Criteria |
Siting Criteria |
False |
False |
|
Depth to Water |
Depth to Water |
False |
False |
|
Site Specific Hydro Geologic |
Site Specific Hydro Geologic |
False |
False |
|
Design and Construction Plan |
Design and Construction Plan |
False |
False |
|
Operation and Maintenance Plan |
Operation and Maintenance Plan |
False |
False |
|
Closure Plan |
Closure Plan |
False |
False |
|
Engineer Closure Cost Estimate |
Engineer Closure Cost Estimate |
False |
False |
|
Engineer Design Drawings |
Engineer Design Drawings |
False |
False |
|
Surface Owner Notification |
Surface Owner Notification |
False |
False |
|
Variance Attachments |
Variance Attachments |
False |
False |
|
As Built Drawings |
As Built Drawings |
False |
False |
|
Closure Report |
Closure Report |
False |
False |
|
Laboratory Analysis Results |
Laboratory Analysis Results |
False |
False |
|
Photographs |
Photographs |
False |
False |
|
Inspection Reports |
Inspection Reports |
False |
False |
|
Construction Notices |
Construction Notices |
False |
False |
|
Cessation Notices |
Cessation of Operations Extension Notices |
False |
False |
|
Closure Notice |
Closure Notice |
False |
False |
|
Reclamation Notice |
Reclamation Notice |
False |
False |
|
|
|
[C-147] Water Recycle Short (C-147S)
• Additionally referred to as: Permit or Registration for Recycling and Re-use of Produced Water, Drilling Fluids and Liquid Oil Field Waste (C-147S).
Click to view expected documentation
Click again to collapse
| Description |
Required to |
Note |
| Tag |
Attachment Type |
Submit |
Approve |
C-147S |
Main Form |
True |
True |
|
Request For Variance |
Request For Variance |
False |
False |
|
Site Map/Topo |
Site Map/Topo |
False |
False |
|
|
|
|
C-148 |
[C-148] EP Recycle Liquid Oil Field Waste Report (RecycleOilWaste)
• Additionally referred to as: Reporting for Recycling and Re-use of Produced Water, Drilling Fluids and Liquid Oil Field Waste (RecycleOilWaste).
|
|
|