OCD Permitting

30-025-00201 NORTH CAPROCK CELERO QUEEN UNIT #026 [317680]

General Well Information
[370922] REMNANT OIL OPERATING, LLC
Active
Oil
Re-entry
Vertical
No
State
State
K-32-12S-32E      1980 FSL      1980 FWL
33.2333717,-103.7424088 NAD83
4373


Single
False


Proposed Formation and/or Notes



Depths

3055
3035
3035
0


Formation Tops

Formation Top Producing Method Obtained

Event Dates

01/01/1900
04/27/2017


04/25/1948


12/18/2023


04/19/2024

02/21/2015







04/19/2024

History
Effective Date Property Well Number Operator C-101 Work Type Well Type Well Status Apd Cancelled Plug Date
04/27/2017 [317680] NORTH CAPROCK CELERO QUEEN UNIT #026 [370922] REMNANT OIL OPERATING, LLC Re-entry Oil Active
05/23/2014 [313271] NORTH CAPROCK CELERO QUEEN UNIT #026 [240974] LEGACY RESERVES OPERATING, LP Re-entry Oil Active
09/05/2013 [39738] NORTH CAPROCK CELERO QUEEN UNIT #026 [247128] CELERO ENERGY II, LP Re-entry Oil Active
02/21/2013 [39738] NORTH CAPROCK CELERO QUEEN UNIT #026 [247128] CELERO ENERGY II, LP Re-entry Oil Active
01/01/1900 [30041] PRE-ONGARD WELL #026K [214263] PRE-ONGARD WELL OPERATOR New Oil Active

Comments

Pits

Pit On Site: Number 01

Drilling

Yes
Inactive

Event Dates



02/21/2013
11/08/2013

Notes

Date Detail
02/21/2013 P1-05786 CLOSED

Casing

  Boreholes, Strings and Equipment Specifications Specifications for Strings and Tubing Strings Cemented and Intervals Cement and Plug Description
String/Hole Type Taper Date Set Diameter Top Bottom (Depth) Grade Length Weight Bot of Cem Top of Cem Meth Class of Cement Sacks Pressure Test (Y/N)
Hole 1 1 04/24/1948 11.000 0 308 0 0.0 0 0 0 No
Surface Casing 1 8.625 0 308 UKN 308 28.0 308 0 Class C Cement 150 No
Hole 2 1 05/04/1948 7.875 308 3035 0 0.0 0 0 0 No
Production Casing 1 05/04/1948 5.500 0 3015 UKN 3015 15.0 0 0 0 No
Tubing 1 1 2.875 0 3035 UKN 3035 0.0 0 0 0 No

Well Completions

[8551]  CAPROCK QUEEN (CHAVES) DO NOT USE

Zone Permanently Plugged
K-32-12S-32E      1980 FSL      1980 FWL
33.2333619674345,-103.742382141512
    
No



Well Test Data


0 psi
0.000 inches
0.0 MCF
0 Kcf / bbl

0 hours
0 psi

0.0 bbls
0.0 Corr. API
0.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth

Notes


Event Dates

02/21/2013
09/06/2013



No
No
No













No







Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
09/06/2013 [39738] NORTH CAPROCK CELERO QUEEN UNIT #026 [247128] CELERO ENERGY II, LP Zone Permanently Plugged
09/05/2013 [39738] NORTH CAPROCK CELERO QUEEN UNIT #026 [247128] CELERO ENERGY II, LP Zones Temporarily Plugged
02/21/2013 [39738] NORTH CAPROCK CELERO QUEEN UNIT #026 [247128] CELERO ENERGY II, LP New, Not Drilled


[8559]  CAPROCK; QUEEN

Active
02/01/2020
K-32-12S-32E      1980 FSL      1980 FWL
33.2333619674345,-103.742382141512
40     32-12S-32E Units: K



Pumping

Well Test Data


0 psi
0.000 inches
0.0 MCF
0 Kcf / bbl

0 hours
0 psi

0.0 bbls
0.0 Corr. API
0.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth
3015 3035 0 0

Notes


Event Dates

01/01/1900
04/27/2017



No
No
No
06/15/1948

11/08/2013
04/19/2014









No







Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
04/27/2017 [317680] NORTH CAPROCK CELERO QUEEN UNIT #026 [370922] REMNANT OIL OPERATING, LLC Active
05/23/2014 [313271] NORTH CAPROCK CELERO QUEEN UNIT #026 [240974] LEGACY RESERVES OPERATING, LP Active
09/05/2013 [39738] NORTH CAPROCK CELERO QUEEN UNIT #026 [247128] CELERO ENERGY II, LP Active
01/01/1900 [30041] PRE-ONGARD WELL #026 [214263] PRE-ONGARD WELL OPERATOR Active

Financial Assurance Please login to review the financial assurance associated with this well.

Compliance

Note that Financial Assurance and Inactive Well Compliance are documented in separate reports (Inactive Well Report, Financial Assurance Report).

Also note that some compliance issues are addressed at the operator level so not listed under each well.



cEZB243348187

Field Inspection
01/25/2024
05/03/2024




Notes

19.15.16.8 Sign on Wells Absent Well Identification Sign Ensure sign meets rule requirements. ( current operator, footages: 1980 FSL 1980 FWL )

Actions/Events

Event Date Category Type



Upstream Natural Gas Venting & Flaring

The upstream natural gas venting & flaring volumes are sourced from upstream natural gas waste reports (C-115B) submissions.

Hide All Upstream Venting & Flaring 10/2021 02/2024
   Venting & Flaring Volumes Beneficial Use
Vented (MCF) Flared (MCF) Total (MCF) Used (MCF)
2021
October (first required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2022
January (second required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2023
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2024
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
Grand Total: 0 0 0 0

Orders Please login to review the orders associated with this well.

Production / Injection

The production & injection volumes are sourced from monthly production reports (C-115) submissions.

Hide All Production Export to Excel 4/2014 2/2020
   Production Injection
Time Frame Oil (BBLS) Gas (MCF) Water (BBLS) Days P/I Water (BBLS) Co2 (MCF) Gas (MCF) Other Pressure
2014
CAPROCK QUEEN (CHAVES) DO NOT USE
Feb 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
CAPROCK;QUEEN
Mar 0 0 0 0 0 0 0 0 0
Apr 35 0 4,655 29 0 0 0 0 0
May 73 0 5,885 31 0 0 0 0 0
Jun 110 0 5,283 30 0 0 0 0 0
Jul 131 0 5,754 31 0 0 0 0 0
Aug 90 0 4,599 31 0 0 0 0 0
Sep 64 0 3,474 30 0 0 0 0 0
Oct 0 0 7,339 0 0 0 0 0 0
Nov 27 0 1,189 30 0 0 0 0 0
Dec 1 0 0 31 0 0 0 0 0
Pool Total: 531 0 38,178 243 0 0 0 0 N/A
2015
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2016
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2017
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2018
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2019
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 1 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 13 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 13 0 0 1 0 0 0 0 N/A
2020
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 13 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 13 0 0 0 0 0 0 0 N/A
2021
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2022
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2023
CAPROCK;QUEEN
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 31 0 0 0 0 0
Sep 0 0 0 31 0 0 0 0 0
Oct 0 0 0 31 0 0 0 0 0
Nov 0 0 0 31 0 0 0 0 0
Dec 0 0 0 31 0 0 0 0 0
Pool Total: 0 0 0 155 0 0 0 0 N/A
2024
CAPROCK;QUEEN
Jan 0 0 0 31 0 0 0 0 0
Feb 0 0 0 29 0 0 0 0 0
Pool Total: 0 0 0 60 0 0 0 0 N/A
Grand Total: 557 0 38,178 459 0 0 0 0 N/A


Transporters
Transporter Product Most Recent for Property

Points of Disposition
ID Type Description Pool(s)
4025224 Oil PRE-ONGARD WELL #026 [8559] CAPROCK;QUEEN
4025223 Gas [8559] CAPROCK;QUEEN
Click to go back to top of page