OCD Permitting

30-025-31202 COMANCHERO #002 [321570]

General Well Information
[141402] FULFER OIL & CATTLE LLC
Active
Gas
New
Vertical
No
Private
Private
G-15-25S-37E      1640 FNL      1980 FEL
32.1330338,-103.1485977 NAD83
3100


Single
False


Proposed Formation and/or Notes



Depths

3050
3025
3050
0


Formation Tops

Formation Top Producing Method Obtained

Event Dates

08/01/1991
06/26/2018








05/15/2017

08/01/1993








History
Effective Date Property Well Number Operator C-101 Work Type Well Type Well Status Apd Cancelled Plug Date
06/26/2018 [321570] COMANCHERO #002 [141402] FULFER OIL & CATTLE LLC New Gas Active
08/01/1991 [14526] COMANCHERO #002 [36671] WESTBROOK OIL CORP New Gas Active

Comments

Pits & Containments No Pits Found
Id Name Rule Status (Capacity) Type Registration
Inspection
Before *
Earliest Effective
Commencement
Last Effective
Cessation
Inspection
After *
Closure
Report
Reclamation
Report
Restoration
Complete

Casing

  Boreholes, Strings and Equipment Specifications Specifications for Strings and Tubing Strings Cemented and Intervals Cement and Plug Description
String/Hole Type Taper Date Set Diameter Top Bottom (Depth) Grade Length Weight Bot of Cem Top of Cem Meth Class of Cement Sacks Pressure Test (Y/N)
Hole 1 1 9.625 0 352 0 0.0 0 0 0 No
Surface Casing 1 9.625 0 352 352 54.0 352 1 Class C Cement 200 No
Hole 3 1 5.500 0 3049 0 0.0 0 0 0 No
Production Casing 1 5.500 0 3049 3049 14.0 3049 1 Class C Cement 475 No
Packer 1 5.500 2929 2934 5 0.0 0 0 0 No
Tubing 1 1 2.375 0 2929 2929 0.0 0 0 0 No

Well Completions

[79240]  JALMAT; TAN-YATES-7 RVRS (GAS)

Active
07/01/2014
G-15-25S-37E      1640 FNL      1980 FEL

NE/160     15-25S-37E Units: A B G H

No

Flowing

Well Test Data


0 psi
0.000 inches
0.0 MCF
0 Kcf / bbl

0 hours
0 psi

0.0 bbls
0.0 Corr. API
0.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth
2470 2934 0 0

Notes


Event Dates

08/01/1991
06/26/2018



No
No
No
08/01/1991












No

08/01/1991





Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
06/26/2018 [321570] COMANCHERO #002 [141402] FULFER OIL & CATTLE LLC Active
08/12/2003 [14526] COMANCHERO #002 [36671] WESTBROOK OIL CORP Active
07/29/2003 [14526] COMANCHERO #002 [36671] WESTBROOK OIL CORP
08/01/1991 [14526] COMANCHERO #002 [36671] WESTBROOK OIL CORP Active

Financial Assurance Please login to review the financial assurance associated with this well.

Compliance

Note that Financial Assurance and Inactive Well Compliance are documented in separate reports (Inactive Well Report, Financial Assurance Report).

Also note that some compliance issues are addressed at the operator level so not listed under each well.



cLWH0201760789

Field Inspection
01/17/2002
04/22/2002


03/28/2002

Notes

WELL SHUT IN, NO GAS METER ! Met w/ Buddy Westbrook 3/28/02, well is producing without a meter Sid Richardson pays on an average well production due to this being a low volume well. CW

Actions/Events

Event Date Category Type
03/28/2002 Corrective Actions Other Notification
01/17/2002 Enforcements Operation/Maintenance
01/17/2002 Notifications Informal Letter (Inspector)


cLWH0321060979

Field Inspection
07/29/2003
09/17/2003


08/12/2003

Notes

IDLE WELL. NEEDS T/A, P/A OR PUT BACK IN USE..

Actions/Events

Event Date Category Type
08/12/2003 Corrective Actions Other Notification
07/29/2003 Enforcements Operation/Maintenance
07/29/2003 Notifications LT2 Unknown letter type



Upstream Natural Gas Venting & Flaring

The upstream natural gas venting & flaring volumes are sourced from upstream natural gas waste reports (C-115B) submissions.

Hide All Upstream Venting & Flaring 10/2021 07/2025
   Venting & Flaring Volumes Beneficial Use
Vented (MCF) Flared (MCF) Total (MCF) Used (MCF)
2021
October (first required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2022
January (second required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2023
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2024
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
2025
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 0
Annual Total: 0 0 0 0
Grand Total: 0 0 0 0

Orders Please login to review the orders associated with this well.

Production / Injection

The production & injection volumes are sourced from monthly production reports (C-115) submissions.

Hide All Production Export to Excel 12/1992 7/2014
   Production Injection
Time Frame Oil (BBLS) Gas (MCF) Water (BBLS) Days P/I Water (BBLS) Co2 (MCF) Gas (MCF) Other Pressure
1992 Cumulative
JALMAT;TAN-YATES-7 RVRS (GAS)
Dec 0 29,496 0 99 0 0 0 0 0
Pool Total: 0 29,496 0 99 0 0 0 0 N/A
1993
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 152 0 31 0 0 0 0 0
Feb 0 133 0 28 0 0 0 0 0
Mar 0 142 0 31 0 0 0 0 0
Apr 0 120 0 30 0 0 0 0 0
May 0 173 0 31 0 0 0 0 0
Jun 0 136 0 30 0 0 0 0 0
Jul 0 134 0 31 0 0 0 0 0
Aug 0 167 0 31 0 0 0 0 0
Sep 0 134 0 30 0 0 0 0 0
Oct 0 195 0 31 0 0 0 0 0
Nov 0 234 0 30 0 0 0 0 0
Dec 0 244 0 31 0 0 0 0 0
Pool Total: 0 1,964 0 365 0 0 0 0 N/A
1994
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 247 0 31 0 0 0 0 0
Feb 0 218 0 28 0 0 0 0 0
Mar 0 242 0 31 0 0 0 0 0
Apr 0 240 0 30 0 0 0 0 0
May 0 238 0 31 0 0 0 0 0
Jun 0 197 0 30 0 0 0 0 0
Jul 0 220 0 31 0 0 0 0 0
Aug 0 208 0 31 0 0 0 0 0
Sep 0 166 0 30 0 0 0 0 0
Oct 0 155 0 31 0 0 0 0 0
Nov 0 144 0 30 0 0 0 0 0
Dec 0 145 0 31 0 0 0 0 0
Pool Total: 0 2,420 0 365 0 0 0 0 N/A
1995
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 144 0 31 0 0 0 0 0
Feb 0 142 0 28 0 0 0 0 0
Mar 0 171 0 31 0 0 0 0 0
Apr 0 166 0 30 0 0 0 0 0
May 0 172 0 31 0 0 0 0 0
Jun 0 176 0 30 0 0 0 0 0
Jul 0 182 0 31 0 0 0 0 0
Aug 0 175 0 31 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 2,040 0 365 0 0 0 0 N/A
1996
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 29 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 178 0 31 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 2,136 0 366 0 0 0 0 N/A
1997
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 28 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 179 0 31 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 2,137 0 365 0 0 0 0 N/A
1998
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 28 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 178 0 31 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 2,136 0 365 0 0 0 0 N/A
1999
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 28 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 178 0 31 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 2,136 0 365 0 0 0 0 N/A
2000
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 29 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 178 0 30 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 1,958 0 335 0 0 0 0 N/A
2001
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 28 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 178 0 31 0 0 0 0 0
Sep 0 178 0 30 0 0 0 0 0
Oct 0 178 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 178 0 31 0 0 0 0 0
Pool Total: 0 2,136 0 365 0 0 0 0 N/A
2002
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 178 0 31 0 0 0 0 0
Feb 0 178 0 28 0 0 0 0 0
Mar 0 178 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 357 0 31 0 0 0 0 0
Jun 0 178 0 30 0 0 0 0 0
Jul 0 185 0 31 0 0 0 0 0
Aug 0 185 0 31 0 0 0 0 0
Sep 0 181 0 30 0 0 0 0 0
Oct 0 188 0 31 0 0 0 0 0
Nov 0 154 0 30 0 0 0 0 0
Dec 0 188 0 31 0 0 0 0 0
Pool Total: 0 2,328 0 365 0 0 0 0 N/A
2003
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 187 0 31 0 0 0 0 0
Feb 0 170 0 28 0 0 0 0 0
Mar 0 188 0 31 0 0 0 0 0
Apr 0 181 0 30 0 0 0 0 0
May 0 188 0 31 0 0 0 0 0
Jun 0 181 0 30 0 0 0 0 0
Jul 0 188 0 31 0 0 0 0 0
Aug 0 188 0 31 0 0 0 0 0
Sep 0 181 0 30 0 0 0 0 0
Oct 0 187 0 31 0 0 0 0 0
Nov 0 182 0 30 0 0 0 0 0
Dec 0 187 0 31 0 0 0 0 0
Pool Total: 0 2,208 0 365 0 0 0 0 N/A
2004
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 187 0 31 0 0 0 0 0
Feb 0 178 0 29 0 0 0 0 0
Mar 0 187 0 31 0 0 0 0 0
Apr 0 182 0 30 0 0 0 0 0
May 0 187 0 31 0 0 0 0 0
Jun 0 181 0 30 0 0 0 0 0
Jul 0 186 0 31 0 0 0 0 0
Aug 0 185 0 31 0 0 0 0 0
Sep 0 181 0 30 0 0 0 0 0
Oct 0 188 0 31 0 0 0 0 0
Nov 0 178 0 30 0 0 0 0 0
Dec 0 185 0 31 0 0 0 0 0
Pool Total: 0 2,205 0 366 0 0 0 0 N/A
2005
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 184 0 31 0 0 0 0 0
Feb 0 170 0 28 0 0 0 0 0
Mar 0 185 0 31 0 0 0 0 0
Apr 0 177 0 30 0 0 0 0 0
May 0 188 0 31 0 0 0 0 0
Jun 0 174 0 30 0 0 0 0 0
Jul 0 187 0 31 0 0 0 0 0
Aug 0 186 0 31 0 0 0 0 0
Sep 0 183 0 30 0 0 0 0 0
Oct 0 186 0 31 0 0 0 0 0
Nov 0 180 0 30 0 0 0 0 0
Dec 0 185 0 31 0 0 0 0 0
Pool Total: 0 2,185 0 365 0 0 0 0 N/A
2006
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 182 0 31 0 0 0 0 0
Feb 0 169 0 28 0 0 0 0 0
Mar 0 185 0 31 0 0 0 0 0
Apr 0 180 0 30 0 0 0 0 0
May 0 194 0 31 0 0 0 0 0
Jun 0 194 0 31 0 0 0 0 0
Jul 0 186 0 31 0 0 0 0 0
Aug 0 183 0 31 0 0 0 0 0
Sep 0 183 0 30 0 0 0 0 0
Oct 0 186 0 31 0 0 0 0 0
Nov 0 180 0 30 0 0 0 0 0
Dec 0 185 0 31 0 0 0 0 0
Pool Total: 0 2,207 0 366 0 0 0 0 N/A
2007
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 192 0 31 0 0 0 0 0
Feb 0 167 0 28 0 0 0 0 0
Mar 0 191 0 31 0 0 0 0 0
Apr 0 179 0 30 0 0 0 0 0
May 0 187 0 31 0 0 0 0 0
Jun 0 188 0 30 0 0 0 0 0
Jul 0 179 0 31 0 0 0 0 0
Aug 0 183 0 31 0 0 0 0 0
Sep 0 181 0 30 0 0 0 0 0
Oct 0 183 0 31 0 0 0 0 0
Nov 0 179 0 30 0 0 0 0 0
Dec 0 184 0 31 0 0 0 0 0
Pool Total: 0 2,193 0 365 0 0 0 0 N/A
2008
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 180 0 31 0 0 0 0 0
Feb 0 171 0 29 0 0 0 0 0
Mar 0 182 0 31 0 0 0 0 0
Apr 0 190 0 30 0 0 0 0 0
May 0 178 0 31 0 0 0 0 0
Jun 0 173 0 30 0 0 0 0 0
Jul 0 184 0 31 0 0 0 0 0
Aug 0 187 0 31 0 0 0 0 0
Sep 0 182 0 30 0 0 0 0 0
Oct 0 182 0 31 0 0 0 0 0
Nov 0 175 0 30 0 0 0 0 0
Dec 0 183 0 31 0 0 0 0 0
Pool Total: 0 2,167 0 366 0 0 0 0 N/A
2009
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 188 0 31 0 0 0 0 0
Feb 0 166 0 28 0 0 0 0 0
Mar 0 185 0 31 0 0 0 0 0
Apr 0 180 0 30 0 0 0 0 0
May 0 184 0 31 0 0 0 0 0
Jun 0 179 0 30 0 0 0 0 0
Jul 0 192 0 31 0 0 0 0 0
Aug 0 190 0 31 0 0 0 0 0
Sep 0 179 0 30 0 0 0 0 0
Oct 0 187 0 31 0 0 0 0 0
Nov 0 181 0 30 0 0 0 0 0
Dec 0 188 0 31 0 0 0 0 0
Pool Total: 0 2,199 0 365 0 0 0 0 N/A
2010
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 188 0 31 0 0 0 0 0
Feb 0 168 0 28 0 0 0 0 0
Mar 0 188 0 31 0 0 0 0 0
Apr 0 173 0 30 0 0 0 0 0
May 0 179 0 31 0 0 0 0 0
Jun 0 174 0 30 0 0 0 0 0
Jul 0 186 0 31 0 0 0 0 0
Aug 0 178 0 31 0 0 0 0 0
Sep 0 182 0 30 0 0 0 0 0
Oct 0 186 0 31 0 0 0 0 0
Nov 0 183 0 30 0 0 0 0 0
Dec 0 182 0 31 0 0 0 0 0
Pool Total: 0 2,167 0 365 0 0 0 0 N/A
2011
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 186 0 31 0 0 0 0 0
Feb 0 168 0 28 0 0 0 0 0
Mar 0 189 0 31 0 0 0 0 0
Apr 0 178 0 30 0 0 0 0 0
May 0 182 0 31 0 0 0 0 0
Jun 0 181 0 30 0 0 0 0 0
Jul 0 182 0 31 0 0 0 0 0
Aug 0 187 0 31 0 0 0 0 0
Sep 0 179 0 30 0 0 0 0 0
Oct 0 116 0 31 0 0 0 0 0
Nov 0 181 0 30 0 0 0 0 0
Dec 0 188 0 31 0 0 0 0 0
Pool Total: 0 2,117 0 365 0 0 0 0 N/A
2012
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 179 0 31 0 0 0 0 0
Feb 0 171 0 29 0 0 0 0 0
Mar 0 186 0 31 0 0 0 0 0
Apr 0 180 0 30 0 0 0 0 0
May 0 179 0 31 0 0 0 0 0
Jun 0 179 0 30 0 0 0 0 0
Jul 0 185 0 31 0 0 0 0 0
Sep 0 182 0 30 0 0 0 0 0
Oct 0 185 0 31 0 0 0 0 0
Nov 0 180 0 30 0 0 0 0 0
Dec 0 185 0 31 0 0 0 0 0
Pool Total: 0 1,991 0 335 0 0 0 0 N/A
2013
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 187 0 31 0 0 0 0 0
Feb 0 172 0 28 0 0 0 0 0
Mar 0 185 0 31 0 0 0 0 0
Apr 0 180 0 30 0 0 0 0 0
May 0 193 0 31 0 0 0 0 0
Jun 0 181 0 30 0 0 0 0 0
Jul 0 178 0 31 0 0 0 0 0
Aug 0 179 0 30 0 0 0 0 0
Sep 0 176 0 30 0 0 0 0 0
Oct 0 182 0 31 0 0 0 0 0
Nov 0 159 0 30 0 0 0 0 0
Dec 0 180 0 31 0 0 0 0 0
Pool Total: 0 2,152 0 364 0 0 0 0 N/A
2014
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 177 0 31 0 0 0 0 0
Feb 0 177 0 28 0 0 0 0 0
Mar 0 182 0 31 0 0 0 0 0
Apr 0 176 0 30 0 0 0 0 0
May 0 182 0 31 0 0 0 0 0
Jun 0 176 0 30 0 0 0 0 0
Jul 0 186 0 31 0 0 0 0 0
Aug 0 0 0 31 0 0 0 0 0
Sep 0 0 0 30 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 1,256 0 273 0 0 0 0 N/A
2015
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 31 0 0 0 0 0
Sep 0 0 0 30 0 0 0 0 0
Oct 0 0 0 31 0 0 0 0 0
Nov 0 0 0 30 0 0 0 0 0
Dec 0 0 0 31 0 0 0 0 0
Pool Total: 0 0 0 153 0 0 0 0 N/A
2016
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 31 0 0 0 0 0
Feb 0 0 0 29 0 0 0 0 0
Mar 0 0 0 31 0 0 0 0 0
Apr 0 0 0 30 0 0 0 0 0
May 0 0 0 31 0 0 0 0 0
Jun 0 0 0 30 0 0 0 0 0
Jul 0 0 0 31 0 0 0 0 0
Aug 0 0 0 30 0 0 0 0 0
Sep 0 0 0 30 0 0 0 0 0
Oct 0 0 0 31 0 0 0 0 0
Nov 0 0 0 30 0 0 0 0 0
Dec 0 0 0 31 0 0 0 0 0
Pool Total: 0 0 0 365 0 0 0 0 N/A
2017
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 31 0 0 0 0 0
Feb 0 0 0 28 0 0 0 0 0
Mar 0 0 0 31 0 0 0 0 0
Apr 0 0 0 30 0 0 0 0 0
May 0 0 0 3 0 0 0 0 0
Jun 0 0 0 30 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 153 0 0 0 0 N/A
2018
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2019
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2020
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2021
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2022
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2023
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2024
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Aug 0 0 0 0 0 0 0 0 0
Sep 0 0 0 0 0 0 0 0 0
Oct 0 0 0 0 0 0 0 0 0
Nov 0 0 0 0 0 0 0 0 0
Dec 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
2025
JALMAT;TAN-YATES-7 RVRS (GAS)
Jan 0 0 0 0 0 0 0 0 0
Feb 0 0 0 0 0 0 0 0 0
Mar 0 0 0 0 0 0 0 0 0
Apr 0 0 0 0 0 0 0 0 0
May 0 0 0 0 0 0 0 0 0
Jun 0 0 0 0 0 0 0 0 0
Jul 0 0 0 0 0 0 0 0 0
Pool Total: 0 0 0 0 0 0 0 0 N/A
Grand Total: 0 75,934 0 8,651 0 0 0 0 N/A


Transporters
Transporter Product Most Recent for Property

Points of Disposition
ID Type Description Pool(s)
2609850 Water [79240] JALMAT;TAN-YATES-7 RVRS (GAS)
2609830 Gas [79240] JALMAT;TAN-YATES-7 RVRS (GAS)
Click to go back to top of page