OCD Permitting

30-015-43555 FOREHAND RANCH 22 STATE #008H [314249]

General Well Information
[249099] CAZA OPERATING, LLC
Active
Gas
New
Horizontal
No
State
State
K-22-23S-27E      2310 FSL      2080 FWL
32.289568,-104.180084 NAD83
3149


Single
False


Proposed Formation and/or Notes



Depths

17685
16790
9180
16672


Formation Tops

Formation Top Producing Method Obtained
Salt 452
Base of Salt 766
Canyon 2195
Bone Spring 5586
Wolfcamp 8997

Event Dates

12/29/2015
02/01/2017


05/01/2017





04/04/2022

12/29/2017


11/30/2017




04/04/2022

History
Effective Date Property Well Number Operator C-101 Work Type Well Type Well Status Apd Cancelled Plug Date
02/01/2017 [314249] FOREHAND RANCH 22 STATE #008H [249099] CAZA OPERATING, LLC New Gas Active
12/29/2015 [314249] FOREHAND RANCH 22 STATE #008H [249099] CAZA OPERATING, LLC New Oil New

Comments

Pits No Pits Found

Casing

  Boreholes, Strings and Equipment Specifications Specifications for Strings and Tubing Strings Cemented and Intervals Cement and Plug Description
String/Hole Type Taper Date Set Diameter Top Bottom (Depth) Grade Length Weight Bot of Cem Top of Cem Meth Class of Cement Sacks Pressure Test (Y/N)
Hole 1 1 17.500 0 755 0 0.0 0 0 0 No
Surface Casing 1 13.375 0 755 J-55 755 54.5 755 0 Circ Class C Cement 690 No
Hole 2 1 12.250 755 7500 0 0.0 0 0 0 No
Intermediate 1 Casing 1 9.625 0 7500 HCL-80 7500 47.0 7500 0 Circ Class C Cement 2605 No
Hole 3 1 8.500 7500 16790 0 0.0 0 0 0 No
Packer 1 5.500 0 9200 0 0.0 0 0 0 No
Production Casing 1 5.500 0 16790 P-110 16790 20.0 16790 0 Circ Type H Cement 2265 No
Tubing 1 1 2.875 0 9200 0 0.0 0 0 0 No

Well Completions

[96409]  FOREHAND RANCH; WOLFCAMP, SW (ABOLISH

Cancelled
N-27-23S-27E      660 FSL      1980 FWL

    




Well Test Data


0 psi
0.000 inches
0.0 MCF
0 Kcf / bbl

0 hours
0 psi

0.0 bbls
0.0 Corr. API
0.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth

Notes


Event Dates

12/29/2015
02/01/2017



No
No
No













No







Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
02/01/2017 [314249] FOREHAND RANCH 22 STATE #008H [249099] CAZA OPERATING, LLC Cancelled
12/29/2015 [314249] FOREHAND RANCH 22 STATE #008H [249099] CAZA OPERATING, LLC New, Not Drilled


[98220]  PURPLE SAGE; WOLFCAMP (GAS)

Active
02/01/2024
N-27-23S-27E      304 FSL      781 FWL

480     27-23S-27E Units: C D E F K L M N
22-23S-27E Units: K L M N

No

Flowing

Well Test Data

01/18/2018
1500 psi
0.480 inches
1500.0 MCF
4274 Kcf / bbl
Sold
24 hours
930 psi
Flowing
351.0 bbls
0.0 Corr. API
3173.0 bbls

Perforations

Date Top Measured Depth
(Where Completion Enters Formation)
Bottom Measured Depth
(End of Lateral)
Top Vertical Depth Bottom Vertical Depth
9583 16385 0 0

Notes


Event Dates

02/01/2017
12/17/2017


04/28/2017
No
Yes
Yes
01/10/2018

12/17/2017
02/23/2018








04/30/2017
No

01/03/2018

02/15/2018
02/23/2018


Well Completion History

Effective Date Property Well Number Operator Completion Status TA Expiration Date
12/17/2017 [314249] FOREHAND RANCH 22 STATE #008H [249099] CAZA OPERATING, LLC Active
02/01/2017 [314249] FOREHAND RANCH 22 STATE #008H [249099] CAZA OPERATING, LLC New, Not Drilled

Financial Assurance Please login to review the financial assurance associated with this well.

Compliance

Note that Financial Assurance and Inactive Well Compliance are documented in separate reports (Inactive Well Report, Financial Assurance Report).

Also note that some compliance issues are addressed at the operator level so not listed under each well.



cAB1726258335

Incident, Spill or Release
09/19/2017
10/19/2017




Notes

C-141 tracking 2RP-4395

Actions/Events

Event Date Category Type
09/19/2017 Enforcements Pollution and Contamination

Reported Releases

The reported release volumes are sourced from C-141 submissions.

Hide All Reported Releases 09/01/2017 01/04/2021
   Release Volumes Additional Details
  BBLS LBS MCF UNK Type Product Severity Status
2021
January
nAPP2100625669   (01/04/2021)
4 0 47 0 Fire
COND, LCRD, NATG, PROD
Major Notification Accepted
Monthly Total: 4 0 47 0  
Annual Total: 4 0 47 0  
2017
September
nAB1726257962   (09/01/2017)
152 0 0 0 Oil Release
LCRD
Major Remediation Plan Approved
Monthly Total: 152 0 0 0  
Annual Total: 152 0 0 0  
Grand Total: 156 0 47 0  

Reported Venting & Flaring

The reported venting & flaring volumes are sourced from C-129 submissions.

Hide All Reported Venting & Flaring 06/09/2022 05/12/2023
   Venting & Flaring Volumes Additional Details
  Flared (MCF) Vented (MCF) Total (MCF) Type Severity Status
2023
May
nAPP2317156174   (05/12/2023)
100 0 100 Flare Minor (06/20/2023)   Initial Data Report Accepted
Monthly Total: 100 0 100  
March
nAPP2317236144   (03/01/2023)
100 0 100 Flare Minor (06/21/2023)   Initial Data Report Accepted
Monthly Total: 100 0 100  
February
nAPP2304453834   (02/11/2023)
900 0 900 Flare Major (02/15/2023)   Amended Data Report Accepted
nAPP2305334290   (02/16/2023)
250 0 250 Flare Minor (02/22/2023)   Initial Data Report Accepted
Monthly Total: 1,150 0 1,150  
Annual Total: 1,350 0 1,350  
2022
November
nAPP2301246179   (11/02/2022)
290 0 290 Flare Minor (01/12/2023)   Initial Data Report Accepted
Monthly Total: 290 0 290  
October
nAPP2230447951   (10/26/2022)
400 0 400 Flare Minor (10/31/2022)   Amended Data Report Accepted
nAPP2230849187   (10/31/2022)
150 0 150 Flare Minor (11/04/2022)   Initial Data Report Accepted
Monthly Total: 550 0 550  
September
nAPP2227237585   (09/26/2022)
250 0 250 Flare Minor (09/29/2022)   Initial Data Report Accepted
Monthly Total: 250 0 250  
June
nAPP2216054700   (06/09/2022)
371 0 371 Flare Major (06/13/2022)   Amended Data Report Accepted
Monthly Total: 371 0 371  
Annual Total: 1,461 0 1,461  
Grand Total: 2,811 0 2,811  

Upstream Natural Gas Venting & Flaring

The upstream natural gas venting & flaring volumes are sourced from upstream natural gas waste reports (C-115B) submissions.

Hide All Upstream Venting & Flaring 10/2021 12/2023
   Venting & Flaring Volumes Beneficial Use
Vented (MCF) Flared (MCF) Total (MCF) Used (MCF)
2021
October (first required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 150 150 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 135 135 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 100 100 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 235 150 385 0
Annual Total: 235 150 385 0
2022
January (second required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 244 244 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 83 0 83 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 131 131 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 15 15 Other alternative beneficial uses approved by the division 50
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 98 375 473 50
April
Emergency 0 0 0 Power generation on lease 60
Non-Scheduled Maintenance or Malfunction 0 75 75 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 75 75 60
May
Emergency 0 0 0 Power generation on lease 60
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 500 500 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 500 500 60
June
Emergency 0 0 0 Power generation on lease 60
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 500 500 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 500 500 60
July
Emergency 0 0 0 Power generation on lease 60
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 300 300 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 300 300 60
August
Emergency 0 0 0 Power generation on lease 60
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 60 60 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 60 60 60
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 250 250 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 60
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 250 250 60
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 550 550 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 60
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 550 550 60
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 500 500 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 60
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 500 500 60
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 150 150 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 60
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 150 150 60
Annual Total: 98 3,260 3,358 590
2023
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 45 45 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 60
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 45 45 60
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 1,150 1,150 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 60
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 1,150 1,150 60
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 50 50 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 50 50 45
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 100 100 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 100 100 45
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 0 0 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 0 0 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 45
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 0 0 45
Annual Total: 0 1,345 1,345 570
Grand Total: 333 4,755 5,088 1,160

Orders Please login to review the orders associated with this well.

Production / Injection

The production & injection volumes are sourced from monthly production reports (C-115) submissions.

Hide All Production Export to Excel 1/2018 2/2024
   Production Injection
Time Frame Oil (BBLS) Gas (MCF) Water (BBLS) Days P/I Water (BBLS) Co2 (MCF) Gas (MCF) Other Pressure
2018
PURPLE SAGE;WOLFCAMP (GAS)
Jan 10,943 21,834 89,342 22 0 0 0 0 0
Feb 18,694 45,561 62,335 28 0 0 0 0 0
Mar 17,604 39,962 57,060 31 0 0 0 0 0
Apr 13,733 33,567 51,913 29 0 0 0 0 0
May 12,224 31,370 52,133 31 0 0 0 0 0
Jun 8,900 28,195 43,545 30 0 0 0 0 0
Jul 8,197 25,866 41,007 31 0 0 0 0 0
Aug 6,929 22,256 36,242 31 0 0 0 0 0
Sep 6,269 19,782 31,305 30 0 0 0 0 0
Oct 5,828 20,781 29,487 31 0 0 0 0 0
Nov 5,259 16,782 26,528 30 0 0 0 0 0
Dec 4,980 17,521 27,130 31 0 0 0 0 0
Pool Total: 119,560 323,477 548,027 355 0 0 0 0 N/A
2019
PURPLE SAGE;WOLFCAMP (GAS)
Jan 4,884 16,862 25,418 31 0 0 0 0 0
Feb 4,085 14,068 21,608 28 0 0 0 0 0
Mar 4,117 14,988 22,321 31 0 0 0 0 0
Apr 4,110 13,215 20,719 30 0 0 0 0 0
May 3,978 13,686 23,591 31 0 0 0 0 0
Jun 3,501 12,755 29,907 30 0 0 0 0 0
Jul 3,782 12,936 20,027 31 0 0 0 0 0
Aug 3,501 12,019 20,688 31 0 0 0 0 0
Sep 2,953 10,545 17,911 30 0 0 0 0 0
Oct 2,791 11,591 21,442 30 0 0 0 0 0
Nov 2,696 11,351 15,202 30 0 0 0 0 0
Dec 2,490 12,144 14,619 31 0 0 0 0 0
Pool Total: 42,888 156,160 253,453 364 0 0 0 0 N/A
2020
PURPLE SAGE;WOLFCAMP (GAS)
Jan 2,513 11,596 9,730 31 0 0 0 0 0
Feb 2,403 10,430 4,721 29 0 0 0 0 0
Mar 2,432 10,937 2,996 31 0 0 0 0 0
Apr 1,791 8,586 4,651 24 0 0 0 0 0
May 0 309 0 1 0 0 0 0 0
Jun 2,121 15,699 14,617 29 0 0 0 0 0
Jul 2,763 11,744 18,275 31 0 0 0 0 0
Aug 2,414 9,992 16,312 31 0 0 0 0 0
Sep 2,245 10,272 16,778 30 0 0 0 0 0
Oct 2,209 11,758 15,644 31 0 0 0 0 0
Nov 2,033 7,705 14,297 30 0 0 0 0 0
Dec 1,816 6,550 11,218 31 0 0 0 0 0
Pool Total: 24,740 115,578 129,239 329 0 0 0 0 N/A
2021
PURPLE SAGE;WOLFCAMP (GAS)
Jan 1,850 12,734 14,212 31 0 0 0 0 0
Feb 1,392 11,038 13,293 26 0 0 0 0 0
Mar 1,669 14,735 15,595 31 0 0 0 0 0
Apr 1,865 10,662 16,836 30 0 0 0 0 0
May 1,465 7,906 15,620 31 0 0 0 0 0
Jun 1,391 9,772 11,588 30 0 0 0 0 0
Jul 1,636 24,243 11,623 31 0 0 0 0 0
Aug 1,549 26,656 13,939 31 0 0 0 0 0
Sep 1,462 21,120 11,613 30 0 0 0 0 0
Oct 1,591 16,607 12,801 31 0 0 0 0 0
Nov 970 10,517 9,132 30 0 0 0 0 0
Dec 478 6,601 3,110 31 0 0 0 0 0
Pool Total: 17,318 172,591 149,362 363 0 0 0 0 N/A
2022
PURPLE SAGE;WOLFCAMP (GAS)
Jan 1,578 4,130 6,386 18 0 0 0 0 0
Feb 1,356 15,577 7,434 27 0 0 0 0 0
Mar 1,731 18,697 10,894 31 0 0 0 0 0
Apr 1,404 17,907 10,896 30 0 0 0 0 0
May 1,521 12,491 11,418 31 0 0 0 0 0
Jun 1,442 11,217 9,764 30 0 0 0 0 0
Jul 1,373 10,298 15,891 31 0 0 0 0 0
Aug 1,380 7,645 10,746 31 0 0 0 0 0
Sep 911 7,995 7,588 30 0 0 0 0 0
Oct 978 6,747 9,033 21 0 0 0 0 0
Nov 1,287 9,065 13,268 30 0 0 0 0 0
Dec 822 29,584 8,522 31 0 0 0 0 0
Pool Total: 15,783 151,353 121,840 341 0 0 0 0 N/A
2023
PURPLE SAGE;WOLFCAMP (GAS)
Jan 1,467 3,831 14,380 31 0 0 0 0 0
Feb 824 13,796 10,217 28 0 0 0 0 0
Mar 649 6,889 6,309 31 0 0 0 0 0
Apr 0 83 19 30 0 0 0 0 0
May 818 4,964 7,653 31 0 0 0 0 0
Jun 804 1,035 7,119 30 0 0 0 0 0
Jul 885 1,178 6,886 31 0 0 0 0 0
Aug 848 1,171 7,295 31 0 0 0 0 0
Sep 868 2,280 10,820 30 0 0 0 0 0
Oct 1,276 6,666 15,037 31 0 0 0 0 0
Nov 1,183 6,143 12,155 30 0 0 0 0 0
Dec 1,119 2,497 13,054 31 0 0 0 0 0
Pool Total: 10,741 50,533 110,944 365 0 0 0 0 N/A
2024
PURPLE SAGE;WOLFCAMP (GAS)
Jan 1,166 3,026 10,799 31 0 0 0 0 0
Feb 878 5,632 9,012 29 0 0 0 0 0
Pool Total: 2,044 8,658 19,811 60 0 0 0 0 N/A
Grand Total: 233,074 978,350 1,332,676 2,177 0 0 0 0 N/A


Transporters
Transporter Product Most Recent for Property
[159160] VERSADO GAS PROCESSORS,LLC Gas 2/2024
[703107] LUCID ENERGY DELAWARE, LLC Gas 8/2022
[214984] PLAINS MARKETING, L.P. Oil 2/2024
[315593] RIO ENERGY INTERNATIONAL, INC. Oil 11/2023
[159160] VERSADO GAS PROCESSORS,LLC Gas 2/2024
[703107] LUCID ENERGY DELAWARE, LLC Gas 8/2022
[214984] PLAINS MARKETING, L.P. Oil 2/2024
[315593] RIO ENERGY INTERNATIONAL, INC. Oil 11/2023

Points of Disposition
ID Type Description Pool(s)
4032102 Gas FOREHAND RANCH 22 STATE #008H [98220] PURPLE SAGE;WOLFCAMP (GAS)
4032101 Oil FOREHAND RANCH 22 STATE #008H [98220] PURPLE SAGE;WOLFCAMP (GAS)
Click to go back to top of page