OCD Permitting

FAPP2129138007 ALDABRA 26 & 27 BATTERY @ P-27-23S-31E 350S 455E

General Facility Information
[6137] DEVON ENERGY PRODUCTION COMPANY, LP
Active
Closure Not Accepted, Pending submission of Monthly/Annual reporting from the operator
Flare Stack - (FS)

P-27-23S-31E      350 FSL      455 FEL
32.269714,-103.758175 NAD83
Artesia
Federal
Eddy (15)


Ground Water (GW) Details

0
No



Notes

This facility was registered on 10/18/2021 by ocaitlin for DEVON ENERGY PRODUCTION COMPANY, LP [6137] (action id: 56474).


Facility Dates

Type Action Effective Received Denied Approved
Commencement of Operations Notice 01/01/1900 09/19/2025

Events

No events Found

History
Effective On Name Operator Status Effective Until
01/01/1900 ALDABRA 26 & 27 BATTERY [6137] DEVON ENERGY PRODUCTION COMPANY, LP

Pits & Containments No Pits Found
Id Name Rule Status (Capacity) Type Registration
Inspection
Before *
Earliest Effective
Commencement
Last Effective
Cessation
Inspection
After *
Closure
Report
Reclamation
Report
Restoration
Complete
Reported Releases

The reported release volumes are sourced from C-141 submissions.

Hide All Reported Releases 08/04/2024 11/30/2025
   Release Volumes Additional Details
  BBLS LBS MCF UNK Type Product Severity Status
2025
November
nAPP2533530107   (11/30/2025)
98 0 0 0 Produced Water Release
LCRD, PROD
Major Initial C-141 Report Approved
Monthly Total: 98 0 0 0  
June
nAPP2518241456   (06/30/2025)
92 0 0 0 Produced Water Release
PROD
Major (10/15/2025)   Liner Report Approved
Monthly Total: 92 0 0 0  
Annual Total: 190 0 0 0  
2024
August
nAPP2421753870   (08/04/2024)
50 0 0 0 Produced Water Release
PROD
Major (10/30/2024)   Liner Report Approved
Monthly Total: 50 0 0 0  
Annual Total: 50 0 0 0  
Grand Total: 240 0 0 0  

Reported Venting & Flaring

The reported venting & flaring volumes are sourced from C-129 submissions.

Hide All Reported Venting & Flaring 10/13/2021 12/18/2025
   Venting & Flaring Volumes Additional Details
  Flared (MCF) Vented (MCF) Total (MCF) Type Severity Status
2025
December
nAPP2535331235   (12/18/2025)
0 226 226 Vent Minor (12/19/2025)   Initial C-129 Report Accepted
Monthly Total: 0 226 226  
October
nAPP2528835542   (10/14/2025)
71 0 71 Flare Minor (10/15/2025)   Initial C-129 Report Accepted
nAPP2528932828   (10/15/2025)
186 0 186 Flare Minor (10/16/2025)   Initial C-129 Report Accepted
Monthly Total: 257 0 257  
August
nAPP2521635460   (08/01/2025)
52 0 52 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2523835904   (08/23/2025)
62 0 62 Flare Minor (08/26/2025)   Initial C-129 Report Accepted
nAPP2524532700   (08/30/2025)
75 0 75 Flare Minor (09/02/2025)   Initial C-129 Report Accepted
Monthly Total: 189 0 189  
July
nAPP2519537615   (07/11/2025)
144 0 144 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2520628188   (07/24/2025)
85 0 85 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2520944531   (07/25/2025)
179 0 179 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2520945372   (07/27/2025)
52 0 52 Flare Minor (07/28/2025)   Initial C-129 Report Accepted
Monthly Total: 460 0 460  
June
nAPP2517830597   (06/25/2025)
269 0 269 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
Monthly Total: 269 0 269  
May
nAPP2513933951   (05/16/2025)
95 0 95 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2514027191   (05/17/2025)
56 0 56 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2514146130   (05/20/2025)
57 0 57 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2514331527   (05/21/2025)
167 0 167 Flare Minor (05/23/2025)   Initial C-129 Report Accepted
nAPP2514333482   (05/22/2025)
199 0 199 Flare Minor (05/23/2025)   Initial C-129 Report Accepted
nAPP2514743637   (05/23/2025)
232 0 232 Flare Minor (05/27/2025)   Initial C-129 Report Accepted
nAPP2514747369   (05/24/2025)
166 0 166 Flare Minor (05/27/2025)   Initial C-129 Report Accepted
Monthly Total: 972 0 972  
April
nAPP2509733663   (04/04/2025)
53 0 53 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2509927551   (04/08/2025)
57 0 57 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2510027683   (04/09/2025)
54 0 54 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2510430540   (04/12/2025)
58 0 58 Flare Minor (04/14/2025)   Initial C-129 Report Accepted
nAPP2511230096   (04/19/2025)
128 0 128 Flare Minor (04/22/2025)   Initial C-129 Report Accepted
nAPP2511334279   (04/22/2025)
106 0 106 Flare Minor (04/23/2025)   Initial C-129 Report Accepted
nAPP2511429741   (04/23/2025)
92 0 92 Flare Minor (04/24/2025)   Initial C-129 Report Accepted
Monthly Total: 548 0 548  
March
nAPP2506429435   (03/03/2025)
147 0 147 Flare Minor (05/12/2025)   Amended C-129 Report Accepted
nAPP2506525949   (03/04/2025)
107 0 107 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2508635773   (03/26/2025)
84 0 84 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
Monthly Total: 338 0 338  
February
nAPP2503656025   (02/03/2025)
106 0 106 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2504930108   (02/16/2025)
150 0 150 Flare Minor (02/19/2025)   Amended C-129 Report Accepted
nAPP2506428872   (02/28/2025)
124 0 124 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
Monthly Total: 380 0 380  
January
nAPP2500635851   (01/03/2025)
79 0 79 Flare Minor (01/06/2025)   Initial C-129 Report Accepted
nAPP2502157448   (01/20/2025)
70 0 70 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2502331684   (01/21/2025)
65 0 65 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2503030411   (01/26/2025)
50 0 50 Flare (01/30/2025)   Initial C-129 Report Accepted
nAPP2503049507   (01/28/2025)
110 0 110 Flare Minor (08/12/2025)   Amended C-129 Report Accepted
nAPP2503152410   (01/29/2025)
141 0 141 Flare Minor (01/31/2025)   Initial C-129 Report Accepted
nAPP2503624622   (01/30/2025)
92 0 92 Flare Minor (02/05/2025)   Initial C-129 Report Accepted
Monthly Total: 607 0 607  
Annual Total: 4,020 226 4,246  
2024
December
nAPP2435837160   (12/21/2024)
119 0 119 Flare Minor (12/23/2024)   Initial C-129 Report Accepted
nAPP2436135580   (12/22/2024)
197 0 197 Flare Minor (12/26/2024)   Initial C-129 Report Accepted
Monthly Total: 316 0 316  
November
nAPP2431137516   (11/05/2024)
54 0 54 Flare Minor (11/06/2024)   Initial C-129 Report Accepted
Monthly Total: 54 0 54  
September
nAPP2424841561   (09/03/2024)
99 0 99 Flare Minor (09/04/2024)   Initial C-129 Report Accepted
Monthly Total: 99 0 99  
August
nAPP2422546437   (08/08/2024)
70 0 70 Flare Minor (08/12/2024)   Initial C-129 Report Accepted
nAPP2422548870   (08/09/2024)
104 0 104 Flare Minor (08/12/2024)   Initial C-129 Report Accepted
nAPP2422631628   (08/11/2024)
104 0 104 Flare Minor (08/13/2024)   Initial C-129 Report Accepted
nAPP2422631862   (08/12/2024)
62 0 62 Flare Minor (08/13/2024)   Initial C-129 Report Accepted
nAPP2422830633   (08/14/2024)
62 0 62 Flare Minor (08/15/2024)   Initial C-129 Report Accepted
nAPP2423434821   (08/20/2024)
60 0 60 Flare Minor (08/21/2024)   Initial C-129 Report Accepted
Monthly Total: 462 0 462  
July
nAPP2419254013   (07/06/2024)
83 0 83 Flare Minor (08/02/2024)   Amended C-129 Report Accepted
Monthly Total: 83 0 83  
June
nAPP2416636937   (06/13/2024)
121 0 121 Flare Minor (06/14/2024)   Initial C-129 Report Accepted
nAPP2416934981   (06/14/2024)
120 0 120 Flare Minor (06/17/2024)   Initial C-129 Report Accepted
nAPP2417243986   (06/19/2024)
108 0 108 Flare Minor (06/20/2024)   Initial C-129 Report Accepted
nAPP2417836719   (06/25/2024)
69 0 69 Flare Minor (06/26/2024)   Initial C-129 Report Accepted
nAPP2418349570   (06/28/2024)
108 0 108 Flare Minor (08/02/2024)   Amended C-129 Report Accepted
Monthly Total: 526 0 526  
May
nAPP2414333903   (05/16/2024)
60 0 60 Flare Minor (05/22/2024)   Initial C-129 Report Accepted
nAPP2414355782   (05/17/2024)
174 0 174 Flare Minor (05/22/2024)   Initial C-129 Report Accepted
nAPP2414442732   (05/18/2024)
177 0 177 Flare Minor (05/23/2024)   Initial C-129 Report Accepted
nAPP2415545766   (05/31/2024)
70 0 70 Flare Minor (06/03/2024)   Initial C-129 Report Accepted
Monthly Total: 481 0 481  
April
nAPP2410853737   (04/16/2024)
87 0 87 Flare Minor (04/17/2024)   Initial C-129 Report Accepted
nAPP2412243996   (04/30/2024)
70 0 70 Flare Minor (05/01/2024)   Initial C-129 Report Accepted
Monthly Total: 157 0 157  
January
nAPP2403054297   (01/27/2024)
81 0 81 Flare Minor (01/30/2024)   Initial C-129 Report Accepted
Monthly Total: 81 0 81  
Annual Total: 2,259 0 2,259  
2023
December
nAPP2335237810   (12/16/2023)
79 0 79 Flare Minor (12/18/2023)   Initial C-129 Report Accepted
nAPP2335242806   (12/17/2023)
83 0 83 Flare Minor (12/18/2023)   Initial C-129 Report Accepted
Monthly Total: 162 0 162  
November
nAPP2331754551   (11/12/2023)
139 0 139 Flare Minor (11/13/2023)   Initial C-129 Report Accepted
nAPP2331828255   (11/13/2023)
61 0 61 Flare Minor (11/14/2023)   Initial C-129 Report Accepted
Monthly Total: 200 0 200  
October
nAPP2327651198   (10/01/2023)
83 0 83 Flare Minor (10/03/2023)   Initial C-129 Report Accepted
Monthly Total: 83 0 83  
September
nAPP2324850048   (09/01/2023)
68 0 68 Flare Minor (09/05/2023)   Initial C-129 Report Accepted
nAPP2326341548   (09/19/2023)
68 0 68 Flare Minor (09/20/2023)   Initial C-129 Report Accepted
nAPP2327626591   (09/30/2023)
91 0 91 Flare Minor (10/03/2023)   Initial C-129 Report Accepted
Monthly Total: 227 0 227  
August
nAPP2322345539   (08/07/2023)
187 0 187 Flare Minor (08/11/2023)   Initial C-129 Report Accepted
nAPP2324040962   (08/26/2023)
52 0 52 Flare Minor (08/28/2023)   Initial C-129 Report Accepted
nAPP2324325583   (08/29/2023)
159 0 159 Flare Minor (08/31/2023)   Initial C-129 Report Accepted
Monthly Total: 398 0 398  
July
nAPP2320032295   (07/18/2023)
52 0 52 Flare Minor (07/19/2023)   Initial C-129 Report Accepted
nAPP2321248016   (07/29/2023)
74 0 74 Flare Minor (07/31/2023)   Initial C-129 Report Accepted
Monthly Total: 126 0 126  
June
nAPP2317157059   (06/17/2023)
83 0 83 Flare Minor (06/20/2023)   Initial C-129 Report Accepted
Monthly Total: 83 0 83  
May
nAPP2313548867   (05/14/2023)
80 0 80 Flare Minor (05/15/2023)   Initial C-129 Report Accepted
Monthly Total: 80 0 80  
April
nAPP2309531971   (04/01/2023)
66 0 66 Flare Minor (04/05/2023)   Initial C-129 Report Accepted
nAPP2309729387   (04/03/2023)
90 0 90 Flare Minor (04/07/2023)   Initial C-129 Report Accepted
nAPP2311451459   (04/17/2023)
71 0 71 Flare Minor (04/24/2023)   Initial C-129 Report Accepted
Monthly Total: 227 0 227  
March
nAPP2306729922   (03/05/2023)
70 0 70 Flare Minor (03/08/2023)   Initial C-129 Report Accepted
nAPP2307325658   (03/09/2023)
81 0 81 Flare Minor (03/14/2023)   Initial C-129 Report Accepted
nAPP2307356533   (03/11/2023)
82 0 82 Flare Minor (03/14/2023)   Initial C-129 Report Accepted
nAPP2308325932   (03/19/2023)
129 0 129 Flare Minor (03/24/2023)   Initial C-129 Report Accepted
nAPP2308350906   (03/22/2023)
111 0 111 Flare Minor (03/24/2023)   Initial C-129 Report Accepted
nAPP2308838921   (03/23/2023)
108 0 108 Flare Minor (03/29/2023)   Initial C-129 Report Accepted
nAPP2309026857   (03/25/2023)
123 0 123 Flare Minor (03/31/2023)   Initial C-129 Report Accepted
Monthly Total: 704 0 704  
February
nAPP2304447392   (02/12/2023)
184 0 184 Flare Minor (02/13/2023)   Initial C-129 Report Accepted
nAPP2304647880   (02/13/2023)
66 0 66 Flare Minor (02/15/2023)   Initial C-129 Report Accepted
nAPP2305355644   (02/20/2023)
78 0 78 Flare Minor (02/22/2023)   Initial C-129 Report Accepted
nAPP2305845767   (02/24/2023)
50 0 50 Flare (02/27/2023)   Initial C-129 Report Accepted
Monthly Total: 378 0 378  
January
nAPP2303050908   (01/28/2023)
142 0 142 Flare Minor (01/30/2023)   Initial C-129 Report Accepted
Monthly Total: 142 0 142  
Annual Total: 2,810 0 2,810  
2022
December
nAPP2234132069   (12/01/2022)
85 0 85 Flare Minor (12/07/2022)   Initial C-129 Report Accepted
nAPP2234255647   (12/02/2022)
132 0 132 Flare Minor (12/08/2022)   Initial C-129 Report Accepted
nAPP2234638362   (12/10/2022)
98 0 98 Flare Minor (12/12/2022)   Initial C-129 Report Accepted
Monthly Total: 315 0 315  
November
nAPP2231332288   (11/01/2022)
0 0 0 Flare (07/26/2023)   Cancellation Request Accepted
nAPP2231332575   (11/02/2022)
0 0 0 Flare (07/26/2023)   Cancellation Request Accepted
nAPP2231332848   (11/03/2022)
0 0 0 Flare (07/26/2023)   Cancellation Request Accepted
nAPP2231333121   (11/04/2022)
0 0 0 Flare (07/26/2023)   Cancellation Request Accepted
nAPP2231333967   (11/05/2022)
0 0 0 Flare (07/26/2023)   Cancellation Request Accepted
nAPP2231342378   (11/07/2022)
51 0 51 Flare Minor (11/09/2022)   Initial C-129 Report Accepted
Monthly Total: 51 0 51  
October
nAPP2230837506   (10/29/2022)
90 0 90 Flare Minor (11/04/2022)   Initial C-129 Report Accepted
nAPP2231150520   (10/30/2022)
79 0 79 Flare Minor (11/07/2022)   Initial C-129 Report Accepted
nAPP2231332000   (10/31/2022)
79 0 79 Flare Minor (11/09/2022)   Initial C-129 Report Accepted
Monthly Total: 248 0 248  
August
nAPP2222447335   (08/02/2022)
78 0 78 Flare Minor (08/12/2022)   Initial C-129 Report Accepted
nAPP2222751193   (08/03/2022)
85 0 85 Flare Minor (08/15/2022)   Initial C-129 Report Accepted
Monthly Total: 163 0 163  
July
nAPP2219254944   (07/06/2022)
74 0 74 Flare Minor (07/11/2022)   Initial C-129 Report Accepted
nAPP2220244009   (07/19/2022)
72 0 72 Flare Minor (07/21/2022)   Initial C-129 Report Accepted
Monthly Total: 146 0 146  
June
nAPP2216647061   (06/11/2022)
50 0 50 Flare (06/15/2022)   Initial C-129 Report Accepted
Monthly Total: 50 0 50  
May
nAPP2213038002   (05/07/2022)
120 0 120 Flare Minor (05/10/2022)   Initial C-129 Report Accepted
nAPP2213329328   (05/08/2022)
55 0 55 Flare Minor (05/13/2022)   Initial C-129 Report Accepted
nAPP2215737727   (05/25/2022)
54 0 54 Flare Minor (06/06/2022)   Initial C-129 Report Accepted
Monthly Total: 229 0 229  
March
nAPP2210839863   (03/23/2022)
195 0 195 Flare Minor (04/18/2022)   Initial C-129 Report Accepted
Monthly Total: 195 0 195  
February
nAPP2204638030   (02/04/2022)
76 0 76 Flare Minor (02/15/2022)   Initial C-129 Report Accepted
nAPP2204249102   (02/05/2022)
122 0 122 Flare Minor (02/11/2022)   Initial C-129 Report Accepted
Monthly Total: 198 0 198  
January
nAPP2201455519   (01/05/2022)
62 0 62 Flare Minor (01/14/2022)   Initial C-129 Report Accepted
nAPP2203352025   (01/24/2022)
51 0 51 Flare Minor (02/02/2022)   Initial C-129 Report Accepted
Monthly Total: 113 0 113  
Annual Total: 1,708 0 1,708  
2021
October
nAPP2129138334   (10/13/2021)
64 0 64 Flare Minor (10/18/2021)   Initial C-129 Report Accepted
Monthly Total: 64 0 64  
Annual Total: 64 0 64  
Grand Total: 10,861 226 11,087  

Upstream Natural Gas Venting & Flaring

The upstream natural gas venting & flaring volumes are sourced from upstream natural gas waste reports (C-115B) submissions.

Hide All Upstream Venting & Flaring 10/2021 10/2025
   Venting & Flaring Volumes Beneficial Use
Vented (MCF) Flared (MCF) Total (MCF) Used (MCF)
2021
October (first required quarterly report)
Emergency 0 64 64 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 34 34 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 169 75 244 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 17 17 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 169 190 359 0
Annual Total: 169 190 359 0
2022
January (second required quarterly report)
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 139 69 208 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 808 808 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 139 877 1,016 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 26 23 49 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 42 42 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 26 65 91 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 1 1 Reinjection for underground storage 0
Storage Tanks 22 21 43 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 545 545 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 22 567 589 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 18 19 37 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 185 185 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 18 204 222 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 7 7 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 18 20 38 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 289 289 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 18 316 334 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 49 49 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 205 205 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 254 254 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 35 35 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 44 44 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 79 79 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 53 53 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 203 203 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 256 256 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 25 25 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 106 106 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 131 131 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 39 39 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 464 464 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 503 503 0
Annual Total: 223 3,252 3,475 0
2023
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 45 45 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 349 349 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 394 394 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 38 38 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 512 512 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 550 550 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 47 47 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 1,116 1,116 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 1,163 1,163 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 45 45 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 380 380 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 425 425 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 35 35 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 111 111 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 146 146 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 18 18 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 134 134 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 152 152 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 35 35 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 214 214 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 249 249 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 9 9 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 411 411 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 420 420 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 23 0 23 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 253 253 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 23 253 276 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 2 2 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 194 194 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 196 196 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 77 0 77 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 7 7 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 406 406 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 77 413 490 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 22 22 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 298 298 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 320 320 0
Annual Total: 100 4,681 4,781 0
2024
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 25 0 25 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 17 17 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 149 149 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 25 166 191 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 53 53 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 57 57 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 110 110 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 55 55 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 18 18 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 73 73 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 52 52 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 339 339 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 391 391 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 43 43 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 595 595 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 638 638 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 47 47 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 741 741 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 788 788 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 47 47 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 247 247 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 294 294 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 52 53 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 592 592 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 644 645 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 39 40 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 160 160 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 199 200 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 30 31 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 262 262 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 292 293 0
November
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 28 29 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 182 182 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 210 211 0
December
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 51 52 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 553 553 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 604 605 0
Annual Total: 30 4,409 4,439 0
2025
January
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 55 56 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 687 687 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 742 743 0
February
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 53 54 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 490 490 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 543 544 0
March
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 56 57 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 506 506 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 562 563 0
April
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 1 0 1 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 36 37 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 821 821 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 2 857 859 0
May
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 47 48 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 1,107 1,107 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 1,154 1,155 0
June
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 22 22 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 515 515 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 537 537 0
July
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 60 61 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 780 780 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 840 841 0
August
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 1 33 34 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 254 254 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 1 287 288 0
September
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 0 2 2 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 135 135 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 0 137 137 0
October
Emergency 0 0 0 Power generation on lease 0
Non-Scheduled Maintenance or Malfunction 0 0 0 Power generation for grid 0
Routine Repair and Maintenance 0 0 0 Compression on lease 0
Routine Downhole Maintenance 0 0 0 Liquids removal on lease 0
Manual Liquid Unloading 0 0 0 Reinjection for underground storage 0
Storage Tanks 2 106 108 Reinjection for temporary storage 0
Insufficient Availability or Capacity 0 452 452 Reinjection for enhanced oil recovery 0
Natural Gas Not Suitable for Transportation or Processing (N2, H2S, or CO2) 0 0 0 Fuel cell production 0
Venting as Result of Normal Operation of Pneumatic Controllers and Pumps 0 0 Other alternative beneficial uses approved by the division 0
Improperly Closed or Maintained Thief Hatch 0 0 Equipment Fuel Gas 0
Venting or Flaring in Excess of Eight Hours 0 0 0 Flare, Combustor or Incinerator pilot fuel 0
Venting And Flaring From An Exploratory Well 0 0 0
Other Surface Waste 0 0 0
Natural Gas Not Suitable for Transportation or Processing (O2) 0 0 0
Report Total: 2 558 560 0
Annual Total: 10 6,217 6,227 0
Grand Total: 532 18,749 19,281 0



Orders No Orders Found


Inspections No Inspections Found

Financial Assurance
Effective Base Balance Issuer Cash/Surety Bond Type Cancellation Date
Requests to release bonds must be submitted in writing. You may send an e-mail to OCD.AdminComp@emnrd.nm.gov.

Click to go back to top of page